A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis

被引:4
|
作者
Yan, Bangji [1 ]
Huang, Xiaotao [1 ,4 ]
Xu, Yingxing [2 ]
Zou, Chengshi [3 ]
机构
[1] Cixi Hosp Tradit Chinese Med, Dept Orthopaed & Traumatol, Ningbo, Peoples R China
[2] Kunming Med Univ, Affiliated Hosp 1, Dept Trauma Ctr, Kunming, Peoples R China
[3] Cixi Hosp Tradit Chinese Med, Dept Radiol, Ningbo, Peoples R China
[4] Cixi Hosp Tradit Chinese Med, Dept Orthopaed & Traumatol, Ningbo 315300, Zhejiang, Peoples R China
关键词
Biomechanics; Finite Element Analysis; Fixation; Locking Buttress Plate; Tibial Plateau Fracture; FIXATION;
D O I
10.1111/os.13660
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The complex tibial plateau fractures involving both medial and posterolateral columns are of frequent occurrence in clinics, but the existing fixation system cannot deal with medial and posterolateral fragments simultaneously. Therefore, a novel locking buttress plate named as medial and posterior column plate (MPCP) was designed in this study to fix the simultaneous medial and posterolateral tibial plateau fractures. Meanwhile, the comparative finite element analysis (FEA) was conducted to investigate the discrepancy between MPCP and traditional multiple plates (MP + PLP) in their biomechanical characteristics.Methods: Two 3D finite element models of simultaneous medial and posterolateral tibial plateau fracture fixed with MPCP and MP + PLP system, respectively, was constructed. To imitate the axial stress of knee joint in ordinary life, diverse axial forces with 100, 500, 1000, and 1500 N were applied in the two fixation models, and then the equivalent displacement and stress nephograms and values were obtained.Results: The similar trend of displacement and stress increasing with the loads was observed in the two fixation models. However, several heterogeneities of displacement and stress distribution were found in the two fixation models. The max displacement and von Mises stress values of plates, screws, and fragments in the MPCP fixation model were significantly smaller than that in the MP + PLP fixation model, except for the max-shear stress values.Conclusion: As a single locking buttress plate, the MPCP system showed the excellent benefit on improving the stability of the simultaneous medial and posterolateral tibial plateau fractures, compared with the traditional double plate fixation system. However, the excessive shear stress around screw holes should be paid attention to prevent trabecular microfracture and screw loosening.
引用
收藏
页码:1104 / 1116
页数:13
相关论文
共 50 条
  • [41] Comparative finite element analysis between three surgical techniques for the treatment of type VI schatzker tibial plateau fractures
    Mitrogiannis, Georgios
    Gkaintes, Orestis A.
    Garnavos, Christos
    Potsika, Vassiliki T.
    Roumpi, Maria
    Gkiatas, Ioannis
    Gelalis, Ioannis D.
    Nikolaou, Vasileios S.
    Mavrogenis, Andreas F.
    Lasanianos, Nikolaos G.
    Geroski, Tijana
    Filipovic, Nenad
    Fotiadis, Dimitrios, I
    Pakos, Emilios
    Babis, Georgios C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (01):
  • [42] Finite Element Analysis of a Novel Anterior Locking Plate for Thoracolumbar Burst Fracture
    Ren, Pengcheng
    Cheng, Xiaodong
    Lu, Chongyao
    Wu, Haotian
    Yao, Shuangquan
    Yang, Sidong
    Song, Zhaohui
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [43] Effect of structural support size and position on depressed tibial plateau fractures: A finite element analysis
    Ren, Xiaomeng
    Xu, Cheng
    Jiang, Yu
    Teng, Da
    Liu, Xinmo
    Wang, Junsong
    Zhang, Wei
    HELIYON, 2024, 10 (08)
  • [44] Finite element analysis of the treatment of a minimally invasive approach combined with a novel anatomical locking plate for scapular body fractures
    Guo, Zhanpeng
    Guo, Yue
    Wang, Yansong
    Bi, Yunlong
    Deng, Yu
    Cao, Yang
    Huang, Mina
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [45] Finite element analysis of a novel anatomical locking plate for scapular neck fracture
    Xiang, Feifan
    Xiao, Yukun
    Wei, Daiqing
    Tan, Xiaoqi
    He, Siyuan
    Luo, Liang
    Yang, Yunkang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [46] Finite element analysis of a novel anatomical locking plate for scapular neck fracture
    Feifan Xiang
    Yukun Xiao
    Daiqing Wei
    Xiaoqi Tan
    Siyuan He
    Liang Luo
    Yunkang Yang
    Journal of Orthopaedic Surgery and Research, 18
  • [47] Comparative Analysis of Single Lateral Locked Plate and Double Locked Plate Application in the Treatment of Bicondylar Tibial Plateau Fractures
    Caglar, Ceyhun
    Akcaalan, Serhat
    Ozaslan, Halil Ibrahim
    Bozer, Merve
    Emre, Fahri
    Ugurlu, Mahmut
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (11)
  • [48] Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
    Huang, Xiaowei
    Zhi, Zhongzheng
    Yu, Baoqing
    Chen, Fancheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [49] Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
    Xiaowei Huang
    Zhongzheng Zhi
    Baoqing Yu
    Fancheng Chen
    Journal of Orthopaedic Surgery and Research, 10
  • [50] Finite Element Analysis of a Novel Anatomical Locking Guide Plate for Anterior Column and Posterior Hemi-Transverse Acetabular Fractures
    Junhao Deng
    Ming Li
    Jiantao Li
    Zhirui Li
    Fanqi Meng
    Yanmei Zhou
    Peifu Tang
    Yanpeng Zhao
    Licheng Zhang