A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis

被引:4
|
作者
Yan, Bangji [1 ]
Huang, Xiaotao [1 ,4 ]
Xu, Yingxing [2 ]
Zou, Chengshi [3 ]
机构
[1] Cixi Hosp Tradit Chinese Med, Dept Orthopaed & Traumatol, Ningbo, Peoples R China
[2] Kunming Med Univ, Affiliated Hosp 1, Dept Trauma Ctr, Kunming, Peoples R China
[3] Cixi Hosp Tradit Chinese Med, Dept Radiol, Ningbo, Peoples R China
[4] Cixi Hosp Tradit Chinese Med, Dept Orthopaed & Traumatol, Ningbo 315300, Zhejiang, Peoples R China
关键词
Biomechanics; Finite Element Analysis; Fixation; Locking Buttress Plate; Tibial Plateau Fracture; FIXATION;
D O I
10.1111/os.13660
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The complex tibial plateau fractures involving both medial and posterolateral columns are of frequent occurrence in clinics, but the existing fixation system cannot deal with medial and posterolateral fragments simultaneously. Therefore, a novel locking buttress plate named as medial and posterior column plate (MPCP) was designed in this study to fix the simultaneous medial and posterolateral tibial plateau fractures. Meanwhile, the comparative finite element analysis (FEA) was conducted to investigate the discrepancy between MPCP and traditional multiple plates (MP + PLP) in their biomechanical characteristics.Methods: Two 3D finite element models of simultaneous medial and posterolateral tibial plateau fracture fixed with MPCP and MP + PLP system, respectively, was constructed. To imitate the axial stress of knee joint in ordinary life, diverse axial forces with 100, 500, 1000, and 1500 N were applied in the two fixation models, and then the equivalent displacement and stress nephograms and values were obtained.Results: The similar trend of displacement and stress increasing with the loads was observed in the two fixation models. However, several heterogeneities of displacement and stress distribution were found in the two fixation models. The max displacement and von Mises stress values of plates, screws, and fragments in the MPCP fixation model were significantly smaller than that in the MP + PLP fixation model, except for the max-shear stress values.Conclusion: As a single locking buttress plate, the MPCP system showed the excellent benefit on improving the stability of the simultaneous medial and posterolateral tibial plateau fractures, compared with the traditional double plate fixation system. However, the excessive shear stress around screw holes should be paid attention to prevent trabecular microfracture and screw loosening.
引用
收藏
页码:1104 / 1116
页数:13
相关论文
共 50 条
  • [31] Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures
    Fancheng Chen
    Xiaowei Huang
    Yingsun Ya
    Fenfen Ma
    Zhi Qian
    Jifei Shi
    Shuolei Guo
    Baoqing Yu
    Journal of Orthopaedic Surgery and Research, 13
  • [32] Comparative analysis of tibial plateau fracture osteosynthesis: A finite element study
    Ferre, Luca Salvadori
    Di Nisio, Felipe Goncalves
    Aguiar Mendonca, Celso Junio
    Belo, Ivan Moura
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 134
  • [33] Finite element analysis of mechanical behavior of stabilization techniques for tibial plateau fractures
    Belaid, D.
    Germaneau, A.
    Bouchoucha, A.
    Bremand, F.
    Breque, C.
    Rigoard, P.
    Vendeuvre, T.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 : 13 - 14
  • [34] Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis
    Yang, Pan
    Zhang, Ying
    Liu, Jian
    Xiao, Jin
    Ma, Li Min
    Zhu, Chang Rong
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (02) : 203 - 209
  • [35] A Novel Design of a Plate for Posterolateral Tibial Plateau Fractures Based on Computed Tomography Mapping of the Proximal Tibiofibular joint
    Ren, Dong
    Liu, Yueju
    Zhou, Bing
    Lu, Jian
    Wang, Pengcheng
    MEDICAL SCIENCE MONITOR, 2018, 24 : 9300 - 9306
  • [36] Unilateral locking plate versus unilateral locking plate combined with compression bolt for Schatzker I-IV tibial plateau fractures: a comparative study
    Wang, Zhongzheng
    Zheng, Zhanle
    Wang, Yuchuan
    Zhu, Yanbin
    Tan, Zhanchao
    Chen, Wei
    Hou, Zhiyong
    Zhang, Yingze
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (05) : 1133 - 1143
  • [37] External fixation using locking plate in distal tibial fracture: a finite element analysis
    Zhang J.
    Ebraheim N.
    Li M.
    He X.
    Schwind J.
    Liu J.
    Zhu L.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (6) : 1099 - 1104
  • [38] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Blazevic, Dejan
    Kodvanj, Janos
    Adamovic, Petra
    Vidovic, Dinko
    Trobonjaca, Zlatko
    Sabalic, Srecko
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [39] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Dejan Blažević
    Janoš Kodvanj
    Petra Adamović
    Dinko Vidović
    Zlatko Trobonjača
    Srećko Sabalić
    Journal of Orthopaedic Surgery and Research, 17
  • [40] Biomechanical analysis of "Barrel hoop plate" technique for the posterolateral fragments of tibial plateau fractures with different displacement tendency
    Zhang, Bin-bin
    Hu, Hai
    Zhan, Shi
    Mei, Jiong
    Zhu, Yi
    Luo, Cong-feng
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (11): : 2465 - 2473