Comparison between Novel Anatomical Locking Guide Plate and Conventional Locking Plate for Acetabular Fractures: A Finite Element Analysis

被引:0
|
作者
Liu, Xiao [1 ,2 ]
Gao, Jianpeng [1 ,2 ]
Wu, Xiaoyong [1 ,2 ]
Deng, Junhao [1 ,2 ]
Li, Zijian [1 ,2 ]
Li, Ran [1 ,2 ]
Zhang, Licheng [1 ,2 ]
Liu, Jianheng [1 ,2 ]
Li, Ming [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthopaed, 28 Fuxin Rd, Beijing 100853, Peoples R China
[2] Natl Clin Res Ctr Orthoped Sports Med & Rehabil, 28 Fuxin Rd, Beijing 100853, Peoples R China
来源
LIFE-BASEL | 2023年 / 13卷 / 11期
关键词
acetabulum; internal fixators; fractures; finite element analysis; ANTERIOR COLUMN; SCREW FIXATION; TRANSVERSE; CLASSIFICATION; VALIDATION; MANAGEMENT; REDUCTION; EFFICACY; PELVIS;
D O I
10.3390/life13112108
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer's computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Finite Element Analysis of a Novel Anterior Locking Plate for Thoracolumbar Burst Fracture
    Ren, Pengcheng
    Cheng, Xiaodong
    Lu, Chongyao
    Wu, Haotian
    Yao, Shuangquan
    Yang, Sidong
    Song, Zhaohui
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [22] Finite element analysis of a novel anatomical plate in posterolateral plateau fractures
    Jian, Zhen
    Jiang, Xinhua
    Li, Dejian
    Zhou, Jianhua
    Yu, Baoqing
    Yi, Chengqing
    FRONTIERS IN SURGERY, 2024, 11
  • [23] Application of a posterior anatomical integrated locking compression plate in the treatment of posterior wall acetabular fractures
    Chen, Jianan
    Huang, Guixiong
    Xue, Peirang
    Guo, Xiaodong
    Chen, Kaifang
    Xu, Yi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [24] A novel model of locking plate and locking spongious screw: a biomechanical in vitro comparison study with classical locking plate
    Parmaksizoglu, Fatih
    Kilic, Sinan
    Cetin, Onur
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [25] EXPERIMENTAL AND PROBABILISTIC FINITE ELEMENT ANALYSIS OF DISTAL FEMORAL FRACTURES: A COMPARISON OF LOCKING PLATE VERSUS INTRAMEDULLARY NAIL FIXATION
    Sales, Christina
    Mercer, Deana
    DeCoster, Thomas A.
    Taha, Mahmoud M. Reda
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 731 - 732
  • [26] Use of a stainless steel locking calcaneal plate for quadrilateral plate buttress in the treatment of acetabular fractures
    Boni, Guilherme
    Pires, Robinson E.
    Sanchez, Gustavo T.
    dos Reis, Fernando B.
    Yoon, Richard S.
    Liporace, Frank A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (05): : 1141 - 1145
  • [27] Use of a stainless steel locking calcaneal plate for quadrilateral plate buttress in the treatment of acetabular fractures
    Guilherme Boni
    Robinson E. Pires
    Gustavo T. Sanchez
    Fernando B. dos Reis
    Richard S. Yoon
    Frank A. Liporace
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1141 - 1145
  • [28] Biomechanical comparison of locking and non-locking patient-specific mandibular reconstruction plate using finite element analysis
    Zhong, Shengping
    Shi, Qimin
    Sun, Yi
    Yang, Shoufeng
    Van Dessel, Jeroen
    Gu, Yifei
    Chen, Xiaojun
    Lubbers, Heinz-Theo
    Politis, Constantinus
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124
  • [29] Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis
    Muftuoglu, G.
    Bayram, B.
    Aydin, P.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : E65 - E69
  • [30] Biomechanical analysis of conventional and locking compression plate (LCP) for treating fibula fracture: A finite element study
    Afandi, Mohamad Hafiz Mohamad
    Ramlee, Muhammad Hanif
    Seng, Gan Hong
    Kadir, Mohammed Rafiq Abdul
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2020, 16 (04): : 433 - 436