Biomechanical Properties of 3-Dimensional Printed Volar Locking Distal Radius Plate: Comparison With Conventional Volar Locking Plate

被引:19
|
作者
Kim, Sung-Jae [1 ]
Jo, Young-Hoon [2 ]
Choi, Wan-Sun [4 ]
Lee, Chang-Hun [3 ]
Lee, Bong-Gun [2 ]
Kim, Joo-Hak [5 ]
Lee, Kwang-Hyun [2 ]
机构
[1] Hallym Univ, Dongtan Sacred Hosp, Coll Med, Dept Orthopaed Surg, Hwasung, South Korea
[2] Hanyang Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
[3] Eulji Univ, Coll Med, Eulji Med Ctr, Dept Orthopaed Surg, 68 Hangeulbiseok Ro, Seoul 139711, South Korea
[4] Ajou Univ, Coll Med, Dept Orthopaed Surg, Suwon, South Korea
[5] Seonam Univ, Myongji Hosp, Coll Med, Dept Orthopaed Surg, Goyang, South Korea
来源
关键词
3-dimensional printing; volar locking plate; distal radial fracture; FRACTURES; FIXATION; BREAKAGE;
D O I
10.1016/j.jhsa.2017.05.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose This study evaluated the biomechanical properties of a new volar locking plate made by 3-dimensional printing using titanium alloy powder and 2 conventional volar locking plates under static and dynamic loading conditions that were designed to replicate those seen during fracture healing and early postoperative rehabilitation. Methods For all plate designs, 12 fourth-generation synthetic composite radii were fitted with volar locking plates according to the manufacturers' technique after segmental osteotomy. Each specimen was first preloaded 10 N and then was loaded to 100 N, 200 N, and 300 N in phases at a rate of 2 N/s. Each construct was then dynamically loaded for 2,000 cycles of fatigue loading in each phase for a total 10,000 cycles. Finally, the constructs were loaded to a failure at a rate of 5 mm/min. Results All 3 plates showed increasing stiffness at higher loads. The 3-dimensional printed volar locking plate showed significantly higher stiffness at all dynamic loading tests compared with the 2 conventional volar locking plates. The 3-dimensional printed volar locking plate had the highest yield strength, which was significantly higher than those of 2 conventional volar locking plates. Conclusions A 3-dimensional printed volar locking plate has similar stiffness to conventional plates in an experimental model of a severely comminuted distal radius fracture in which the anterior and posterior metaphyseal cortex are involved. (Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:747.e1 / 747.e6
页数:6
相关论文
共 50 条
  • [1] A biomechanical comparison between two volar locking plate systems for distal radius fractures
    Chen, Li
    Dai, Qiang
    Wongworawat, Montri D.
    ORTHOPEDICS, 2006, 29 (10) : 927 - 929
  • [2] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [3] Mechanical failure of the distal radius volar locking plate
    Foo, Tun-Lin
    Gan, Aaron W. T.
    Soh, Tamara
    Chew, Winston Y. C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 332 - 336
  • [4] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13
  • [5] Treatment of unstable distal radius fractures with the volar locking plate
    Minegishi, Hanae
    Dohi, Osamu
    An, Soukan
    Sato, Hidetsugu
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 280 - 284
  • [6] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [7] Breakage of volar locking plate system for distal radius fractures
    Kawanishi, Syohei
    Gato, Uasushi
    Nakai, Tsuyoshi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 71 - 77
  • [8] Comparison of 2 surgical approaches for volar locking plate osteosynthesis of the distal radius
    Lattmann, Thomas
    Dietrich, Michael
    Meier, Christoph
    Kilgus, Martin
    Platz, Andreas
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (07): : 1135 - 1143
  • [9] Complications after volar locking plate fixation of distal radius fractures
    Johnson, N. A.
    Cutler, L.
    Dias, J. J.
    Ullah, A. S.
    Wildin, C. J.
    Bhowal, B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 528 - 533
  • [10] Volar locking compression T-plate for distal radius fractures
    Lattmann, T
    Dietrich, M
    Meier, C
    Kilgus, M
    Platz, A
    BRITISH JOURNAL OF SURGERY, 2005, 92 (07) : 905 - 905