Robust PLL-Based Grid Synchronization and Frequency Monitoring

被引:2
|
作者
Iov, Florin [1 ]
Zhao, Weihao [2 ]
Kerekes, Tamas [1 ]
机构
[1] Aalborg Univ, Dept Energy, DK-9220 Aalborg, Denmark
[2] Silicon Austria Labs, A-8010 Graz, Austria
关键词
distorted low-voltage grids; grid synchronization; phase-lock-loop; frequency estimation; SYSTEMS; DESIGN;
D O I
10.3390/en16196856
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Nowadays, the penetration of inverter-based energy resources is continuously increasing in low-voltage distribution grids. Their applications cover traditional renewable energy production and energy storage but also new applications such as charging points for electric vehicles, heat pumps, electrolyzers, etc. The power ratings range from a couple of kW to hundreds of kW. Utilities have, in the last few years, reported more challenges regarding power quality in distribution grids, e.g., high harmonic content, high unbalances, large voltage and frequency excursions, etc. Phase-Lock-Loop (PLL) algorithms are typically used for grid synchronization and decoupled control of power converters connected to the grid. Most of the research within PLLs is mainly focusing on grid voltage angle estimation while the byproducts of the algorithms, e.g., frequency and voltage magnitude, are often overlooked. However, both frequency and voltage magnitude estimations are crucial for grid code compliance. Practical considerations for implementation on microcontroller boards of these algorithms are also missing in most of the cases. The present paper proposes a modified PLL algorithm based on a Synchronous Reference Frame that is suitable for both grid synchronization and frequency monitoring, i.e., the estimation of RMS phase voltages and frequencies in highly distorted distribution grids. It also provides the tuning methodology and practical considerations for implementation on commercial DSP boards. The performance of the proposed approach is assessed through simulation studies and laboratory tests under a wide range of operational conditions, showing that the proposed PLL can estimate the grid frequency, for all considered grid events, with an accuracy of less than +/- 5 mHz, which is a significant improvement on the current state-of-the-art solutions, having an accuracy of at least +/- 20 mHz or more.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid
    Hu, Qi
    Fu, Lijun
    Ma, Fan
    Ji, Feng
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (04) : 3220 - 3229
  • [32] Improving the acquisition time of a PLL-based, integer-N frequency synthesizer
    Ahmed, SI
    Mason, RD
    2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 4, PROCEEDINGS, 2004, : 365 - 368
  • [33] Grid Synchronization PLL Based on Cascaded Delayed Signal Cancellation
    Wang, Yi Fei
    Li, Yun Wei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (07) : 1987 - 1997
  • [34] A novel, PLL-based frequency-to-digital conversion mechanism for sensor interfaces
    Danneels, H.
    Piette, F.
    De Smedt, V.
    Dehaene, W.
    Gielen, G.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 172 (01) : 220 - 227
  • [35] Grid Synchronization PLL based on Cascaded Delayed Signal Cancellation
    Wang, Yi Fei
    Li, Yun Wei
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 420 - 427
  • [36] An Adaptive Neural PLL for Grid Synchronization
    Bechouche, Ali
    Sediki, Hamid
    Abdeslam, Djaffar Quid
    Haddad, Salah
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 4451 - 4456
  • [37] Transient synchronization stability analysis of PLL-based VSC using Lyapunov's direct method
    Wang, Tong
    Ji, Taipeng
    Jiao, Dian
    Li, Yongda
    Wang, Zengping
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [38] A PLL-Based approach to clock synchronization for trajectory rebuilding in event-triggered communication systems
    Rossi, Carlo
    Spera, Manuel
    ETFA 2007: 12TH IEEE INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION, VOLS 1-3, 2007, : 1457 - 1464
  • [39] Modeling of the PLL-based bioimpedance measurement system
    Paavle, T
    Min, M
    BEC 2004: PROCEEDING OF THE 9TH BIENNIAL BALTIC ELECTRONICS CONFERENCE, 2004, : 183 - 186
  • [40] Small Signal Synchronizing Stability Analysis of PLL-based VSC Connected to Weak AC Grid
    Hu Q.
    Fu L.
    Ma F.
    Ji F.
    Zhang Y.
    Wang G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (01): : 98 - 108