摘要
Similar large signal synchronizing instability that is common in traditional power system also exists in voltage source converter (VSC) dominated power system, which is increasingly reported and investigated. In this paper, the large signal instability of phase locked loop (PLL) synchronized VSC connected to weak ac grid is investigated. First, the influence of high grid impedance on PLL's dynamics is explored and an additional feedback loop is found to be introduced, which deteriorates the performance of PLL. Then an analysis model that is similar as the rotor motion model of synchronous generator (SG) is developed. Based on the developed model, equal-area method is employed to carry out the large-signal stability' analysis. The large signal instability is found to be mainly resulted by the following two factors. One is the nonexistence of equilibrium point, which is similar as that there does not exist intersection between the mechanical power input curve and electromagnetic restoring force curve in SG grid connected system. The other is related with the transition process resulted by insufficient decelerating area, which leads to that the system cannot stably go through the transition from initial point to the existing equilibrium point. The proposed analysis not only contributes to revealing the physical mechanism but also provides guidance for the future improvement measures.
引用
收藏
页码:3220 / 3229
页数:10
相关论文
共 21 条
[1]  
[Anonymous], 1994, POWER SYSTEM STABILI
[2]   Power electronics as efficient interface in dispersed power generation systems [J].
Blaabjerg, F ;
Chen, Z ;
Kjaer, SB .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (05) :1184-1194
[3]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[4]   Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1254-1261
[5]   STABILITY REGIONS OF NONLINEAR AUTONOMOUS DYNAMICAL-SYSTEMS [J].
CHIANG, HD ;
HIRSCH, MW ;
WU, FF .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1988, 33 (01) :16-27
[6]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[7]   Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions [J].
Dong, Dong ;
Wen, Bo ;
Boroyevich, Dushan ;
Mattavelli, Paolo ;
Xue, Yaosuo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) :310-321
[8]   VSC-Based HVDC Power Transmission Systems: An Overview [J].
Flourentzou, Nikolas ;
Agelidis, Vassilios G. ;
Demetriades, Georgios D. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (3-4) :592-602
[9]   Instability of Wind Turbine Converters During Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability Solution [J].
Goksu, Omer ;
Teodorescu, Remus ;
Bak, Claus Leth ;
Iov, Florin ;
Kjaer, Philip Carne .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (04) :1683-1691
[10]   Input-admittance calculation and shaping for controlled voltage-source converters [J].
Harnefors, Lennart ;
Bongiorno, Massimo ;
Lundberg, Stefan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (06) :3323-3334