Robust PLL-Based Grid Synchronization and Frequency Monitoring

被引:2
|
作者
Iov, Florin [1 ]
Zhao, Weihao [2 ]
Kerekes, Tamas [1 ]
机构
[1] Aalborg Univ, Dept Energy, DK-9220 Aalborg, Denmark
[2] Silicon Austria Labs, A-8010 Graz, Austria
关键词
distorted low-voltage grids; grid synchronization; phase-lock-loop; frequency estimation; SYSTEMS; DESIGN;
D O I
10.3390/en16196856
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Nowadays, the penetration of inverter-based energy resources is continuously increasing in low-voltage distribution grids. Their applications cover traditional renewable energy production and energy storage but also new applications such as charging points for electric vehicles, heat pumps, electrolyzers, etc. The power ratings range from a couple of kW to hundreds of kW. Utilities have, in the last few years, reported more challenges regarding power quality in distribution grids, e.g., high harmonic content, high unbalances, large voltage and frequency excursions, etc. Phase-Lock-Loop (PLL) algorithms are typically used for grid synchronization and decoupled control of power converters connected to the grid. Most of the research within PLLs is mainly focusing on grid voltage angle estimation while the byproducts of the algorithms, e.g., frequency and voltage magnitude, are often overlooked. However, both frequency and voltage magnitude estimations are crucial for grid code compliance. Practical considerations for implementation on microcontroller boards of these algorithms are also missing in most of the cases. The present paper proposes a modified PLL algorithm based on a Synchronous Reference Frame that is suitable for both grid synchronization and frequency monitoring, i.e., the estimation of RMS phase voltages and frequencies in highly distorted distribution grids. It also provides the tuning methodology and practical considerations for implementation on commercial DSP boards. The performance of the proposed approach is assessed through simulation studies and laboratory tests under a wide range of operational conditions, showing that the proposed PLL can estimate the grid frequency, for all considered grid events, with an accuracy of less than +/- 5 mHz, which is a significant improvement on the current state-of-the-art solutions, having an accuracy of at least +/- 20 mHz or more.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Large-Signal Grid-Synchronization Stability Analysis of PLL-Based VSCs Using Lyapunov's Direct Method
    Zhang, Yu
    Zhang, Chen
    Cai, Xu
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2022, 37 (01) : 788 - 791
  • [22] A wide-band PLL-based frequency synthesizer with adaptive dynamics
    Wu, Ping-Heng
    Yang, Ching-Yuan
    Chao, So-Ya
    TENCON 2007 - 2007 IEEE REGION 10 CONFERENCE, VOLS 1-3, 2007, : 981 - 984
  • [23] Implementation of a PLL-based High Frequency Resonant AC Power Supply
    Lin, Pao-Chuan
    Ku, Ying-Ying
    Lai, Ching-Ming
    Liao, Yi-Hung
    Huang, Yi-Shuo
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 1270 - +
  • [24] Dominant Transient Unstable Characteristics of PLL-based Grid-connected Converters
    Zhang Y.
    Zhan M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (23): : 9285 - 9296
  • [25] Optimization of the PLL Configuration in a PLL-based TRNG Design
    Allini, Elie Noumon
    Petura, Oto
    Fischer, Viktor
    Bernard, Florent
    PROCEEDINGS OF THE 2018 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2018, : 1265 - 1270
  • [26] Modeling and simulation of PLL-based frequency-synthesizers for FMCW radar
    Pichler, Markus
    Stelzer, Andreas
    Seisenberger, Claus
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 1540 - +
  • [27] Analysis in DSC-PLL Grid Synchronization Method under Grid Frequency Variation
    Lee, Jaedo
    Cha, Hanju
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 949 - 953
  • [28] A frequency synchronization scheme based on PLL for BiSAR
    Tian, Weiming
    Hu, Shanqing
    Zeng, Tao
    ICSP: 2008 9TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-5, PROCEEDINGS, 2008, : 2422 - 2425
  • [29] Impact of PLL Frequency Limiter on Synchronization Stability of Grid Feeding Converter
    Chen, Junru
    Liu, Muyang
    Geng, Hua
    O'Donnell, Terence
    Milano, Federico
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2022, 37 (03) : 2487 - 2490
  • [30] A PLL-Based Controller for Three-Phase Grid-Connected Power Converters
    Golestan, Saeed
    Guerrero, Josep M.
    Vasquez, Juan. C.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (02) : 911 - 916