Pseudo multishot echo-planar imaging for geometric distortion improvement

被引:1
|
作者
Chen, Hao [1 ,2 ]
Dai, Ke [1 ]
Bao, Jianfeng [3 ]
Zhong, Sijie [1 ]
Hu, Chenxi [1 ]
Liu, Yiling [1 ]
Zhang, Zhiyong [1 ,2 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai, Peoples R China
[3] First Affiliated Hosp Zhengzhou Univ, Funct Magnet Resonance & Mol Imaging Key Lab Henan, Zhengzhou, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Biomed Engn, 1954 Huashan Rd, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金; 上海市科技启明星计划;
关键词
distortion; EPI; multishot; GRADIENT-ECHO; OFF-RESONANCE; PARALLEL MRI; DIFFUSION; SPIN; EPI; SENSE; IMAGES;
D O I
10.1002/nbm.4885
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Conventional echo-planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off-resonance and T-2* decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new "multishot" EPI method termed pseudo multishot EPI (pmsEPI), in which phase-encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3-T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion-weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single-shot blip up and down acquisition.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Echo-planar MR imaging - Reply
    Edelman, RR
    RADIOLOGY, 1996, 198 (02) : 586 - 586
  • [42] Echo-planar imaging of the fetus and placenta
    Symonds, EM
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 519 - 521
  • [43] Multishot echo-planar imaging with gadopentetate dimeglumine - Preliminary study of efficacy for detection of hypovascular metastatic liver tumors
    Murakami, T
    Kim, T
    Hori, M
    Takamura, M
    Tsuda, K
    Takahashi, S
    Narumi, Y
    Nakamura, H
    ACTA RADIOLOGICA, 2000, 41 (03) : 263 - 268
  • [44] Diagnostic performance of multishot echo-planar imaging (RESOLVE) and non-echo-planar imaging (HASTE) diffusion-weighted imaging in cholesteatoma with an emphasis on signal intensity ratio measurement
    Bozer, Ahmet
    Adibelli, Zehra Hilal
    Yener, Yesim
    Dalgic, Abdullah
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (06): : 370 - 377
  • [45] Distortion correction for a double inversion-recovery sequence with an echo-planar imaging readout
    Meara, Simon J. P.
    Ernbleton, Karl V.
    Parker, Geoffrey J. M.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (07) : 943 - 953
  • [46] Two-dimensional Fourier transform multishot echo-planar coronary MR angiography
    Slavin, GS
    Riederer, SJ
    RADIOLOGY, 1996, 201 : 357 - 357
  • [47] Echo-planar rotating-frame imaging
    Casanova, F
    Robert, H
    Perlo, J
    Pusiol, D
    JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (02) : 396 - 401
  • [48] LIMITS TO NEURAL STIMULATION IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    HARVEY, PR
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 746 - 758
  • [49] Reducing flow artifacts in echo-planar imaging
    Pat, GTL
    Meyer, CH
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 436 - 447
  • [50] Multiple-shot echo-planar imaging
    Hennel, F