Pseudo multishot echo-planar imaging for geometric distortion improvement

被引:1
|
作者
Chen, Hao [1 ,2 ]
Dai, Ke [1 ]
Bao, Jianfeng [3 ]
Zhong, Sijie [1 ]
Hu, Chenxi [1 ]
Liu, Yiling [1 ]
Zhang, Zhiyong [1 ,2 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai, Peoples R China
[3] First Affiliated Hosp Zhengzhou Univ, Funct Magnet Resonance & Mol Imaging Key Lab Henan, Zhengzhou, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Biomed Engn, 1954 Huashan Rd, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金; 上海市科技启明星计划;
关键词
distortion; EPI; multishot; GRADIENT-ECHO; OFF-RESONANCE; PARALLEL MRI; DIFFUSION; SPIN; EPI; SENSE; IMAGES;
D O I
10.1002/nbm.4885
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Conventional echo-planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off-resonance and T-2* decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new "multishot" EPI method termed pseudo multishot EPI (pmsEPI), in which phase-encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3-T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion-weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single-shot blip up and down acquisition.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [12] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [13] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    eMagRes, 2007,
  • [14] Comparison of single-shot and multishot echo-planar imaging and conventional SE MR imaging of the brain
    Bradley, WG
    Chen, D
    Douglas, MR
    Ramirez, GF
    Slocum, GR
    Vu, BT
    RADIOLOGY, 1996, 201 : 982 - 982
  • [15] Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions
    Chauhan, Munish
    Shankar, Rohini Vidya
    Kumar, Neeta Ashok
    Kodibagkar, Vikram D.
    Sadleir, Rosalind
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 71 - 82
  • [16] Silicone-selective multishot echo-planar imaging for rapid MRI survey of breast implants
    Amano, Yasuo
    Aoki, Ritsu
    Kumita, Shinichiro
    Kumazaki, Tatsuo
    EUROPEAN RADIOLOGY, 2007, 17 (07) : 1875 - 1878
  • [17] Silicone-selective multishot echo-planar imaging for rapid MRI survey of breast implants
    Yasuo Amano
    Ritsu Aoki
    Shinichiro Kumita
    Tatsuo Kumazaki
    European Radiology, 2007, 17 : 1875 - 1878
  • [18] ECHO-PLANAR IMAGING OF PERFLUOROCARBONS
    BARKER, BR
    MASON, RP
    PESHOCK, RM
    MAGNETIC RESONANCE IMAGING, 1993, 11 (08) : 1165 - 1173
  • [19] ADVANCES IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    DOYLE, M
    CHAPMAN, B
    GUILFOYLE, D
    CAWLEY, M
    COUPLAND, RE
    CHRISPIN, A
    SMALL, P
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 583 - 584
  • [20] Echo-planar imaging of the uterus
    Kiryu, S
    Okada, Y
    Matsuoka, Y
    Abe, O
    Ohtomo, K
    Sasaki, Y
    RADIOLOGY, 1996, 201 : 595 - 595