Pseudo multishot echo-planar imaging for geometric distortion improvement

被引:1
|
作者
Chen, Hao [1 ,2 ]
Dai, Ke [1 ]
Bao, Jianfeng [3 ]
Zhong, Sijie [1 ]
Hu, Chenxi [1 ]
Liu, Yiling [1 ]
Zhang, Zhiyong [1 ,2 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai, Peoples R China
[3] First Affiliated Hosp Zhengzhou Univ, Funct Magnet Resonance & Mol Imaging Key Lab Henan, Zhengzhou, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Biomed Engn, 1954 Huashan Rd, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金; 上海市科技启明星计划;
关键词
distortion; EPI; multishot; GRADIENT-ECHO; OFF-RESONANCE; PARALLEL MRI; DIFFUSION; SPIN; EPI; SENSE; IMAGES;
D O I
10.1002/nbm.4885
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Conventional echo-planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off-resonance and T-2* decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new "multishot" EPI method termed pseudo multishot EPI (pmsEPI), in which phase-encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3-T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion-weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single-shot blip up and down acquisition.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Echo-planar MR imaging
    Kanal, E
    RADIOLOGY, 1996, 198 (02) : 585 - 586
  • [22] Radial echo-planar imaging
    Silva, AC
    Barbier, EL
    Lowe, IJ
    Koretsky, AP
    JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) : 242 - 247
  • [23] ECHO-PLANAR IMAGING OF THE ABDOMEN
    MULLER, MF
    EDELMAN, RR
    TOPICS IN MAGNETIC RESONANCE IMAGING, 1995, 7 (02) : 112 - 119
  • [24] Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging
    Yeo, Desmond T. B.
    Fessler, Jeffrey A.
    Kim, Boklye
    MAGNETIC RESONANCE IMAGING, 2008, 26 (05) : 703 - 714
  • [25] Two-dimensional multishot echo-planar coronary MR angiography
    Magnetic Resonance Laboratory, Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN, United States
    不详
    Magn. Reson. Med., 6 (883-889):
  • [26] Two-dimensional multishot echo-planar coronary MR angiography
    Slavin, GS
    Riederer, SJ
    Ehman, RL
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) : 883 - 889
  • [27] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tamada, T
    Sone, T
    Nagai, K
    Jo, Y
    Gyoten, M
    Imai, S
    Kajihara, Y
    Fukunaga, M
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 318 - 325
  • [28] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tsutomu Tamada
    Teruki Sone
    Kiyohisa Nagai
    Yoshimasa Jo
    Masayuki Gyoten
    Shigeki Imai
    Yasumasa Kajihara
    Masao Fukunaga
    European Radiology, 2004, 14 : 318 - 325
  • [29] Water/fat separation for self-navigated diffusion-weighted multishot echo-planar imaging
    Dong, Yiming
    Riedel, Malte
    Koolstra, Kirsten
    van Osch, Matthias J. P.
    Bornert, Peter
    NMR IN BIOMEDICINE, 2023, 36 (01)
  • [30] Evaluation of Motion-Corrected Multishot Echo-Planar Imaging as an Alternative to Gradient Recalled-Echo for Blood-Sensitive Imaging
    Murchison, J. A.
    Shoshan, D.
    Ooi, M. B.
    Li, Z.
    Karis, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (06) : 665 - 667