Reducing flow artifacts in echo-planar imaging

被引:20
|
作者
Pat, GTL
Meyer, CH
Pauly, JM
Nishimura, DG
机构
[1] Department of Electrical Engineering, Stanford University, Stanford, CA
[2] Durand 303, Information Systems Laboratory, Stanford University, Stanford
关键词
magnetic resonance imaging; echo-planar imaging; flow artifacts;
D O I
10.1002/mrm.1910370323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar imaging (EPI) is very susceptible to flow artifacts, Two ways to improve its flow properties are presented. First, ''partial flyback'' is proposed to reduce artifacts arising from flow in the readout direction. Near the center of k-space, only the even echoes of the EPI echo-train are used. Partial flyback is shown to improve the readout-flow properties at the expense of a slight worsening of the phase-encode flow and off-resonance properties. We recommend that the flyback region acquire 95% of the energy in k-space. Second, ''inside-out'' EPI is used to reduce artifacts arising from flow in the phase-encode direction, Data collection begins at the center of k-space, with separate interleaves to acquire the top and bottom halves of k-space, Partial flyback is combined with partial-Fourier EPI and inside-out EPI. Partial-flyback inside-out EPI has worse off-resonance properties than partial-flyback partial-fourier EPI but demonstrates better flow properties and does not require partial k-space reconstruction.
引用
收藏
页码:436 / 447
页数:12
相关论文
共 50 条
  • [1] Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Bolster, BD
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 429 - 439
  • [2] ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING
    BUTTS, K
    RIEDERER, SJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 285 - 293
  • [3] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [4] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    eMagRes, 2007,
  • [5] Image-based reduction of artifacts in multishot echo-planar imaging
    Hennel, F
    JOURNAL OF MAGNETIC RESONANCE, 1998, 134 (02) : 206 - 213
  • [6] Image-Based Reduction of Artifacts in Multishot Echo-Planar Imaging
    MR Centre, FORENAP, 68250 Rouffach, France
    J. Magn. Reson., 2 (206-213):
  • [7] ECHO-PLANAR IMAGING OF PERFLUOROCARBONS
    BARKER, BR
    MASON, RP
    PESHOCK, RM
    MAGNETIC RESONANCE IMAGING, 1993, 11 (08) : 1165 - 1173
  • [8] ADVANCES IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    DOYLE, M
    CHAPMAN, B
    GUILFOYLE, D
    CAWLEY, M
    COUPLAND, RE
    CHRISPIN, A
    SMALL, P
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 583 - 584
  • [9] Echo-planar imaging of the uterus
    Kiryu, S
    Okada, Y
    Matsuoka, Y
    Abe, O
    Ohtomo, K
    Sasaki, Y
    RADIOLOGY, 1996, 201 : 595 - 595
  • [10] Echo-planar MR imaging
    Kanal, E
    RADIOLOGY, 1996, 198 (02) : 585 - 586