Reducing flow artifacts in echo-planar imaging

被引:20
|
作者
Pat, GTL
Meyer, CH
Pauly, JM
Nishimura, DG
机构
[1] Department of Electrical Engineering, Stanford University, Stanford, CA
[2] Durand 303, Information Systems Laboratory, Stanford University, Stanford
关键词
magnetic resonance imaging; echo-planar imaging; flow artifacts;
D O I
10.1002/mrm.1910370323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar imaging (EPI) is very susceptible to flow artifacts, Two ways to improve its flow properties are presented. First, ''partial flyback'' is proposed to reduce artifacts arising from flow in the readout direction. Near the center of k-space, only the even echoes of the EPI echo-train are used. Partial flyback is shown to improve the readout-flow properties at the expense of a slight worsening of the phase-encode flow and off-resonance properties. We recommend that the flyback region acquire 95% of the energy in k-space. Second, ''inside-out'' EPI is used to reduce artifacts arising from flow in the phase-encode direction, Data collection begins at the center of k-space, with separate interleaves to acquire the top and bottom halves of k-space, Partial flyback is combined with partial-Fourier EPI and inside-out EPI. Partial-flyback inside-out EPI has worse off-resonance properties than partial-flyback partial-fourier EPI but demonstrates better flow properties and does not require partial k-space reconstruction.
引用
收藏
页码:436 / 447
页数:12
相关论文
共 50 条
  • [21] INTERLEAVED ASYMMETRIC ECHO-PLANAR IMAGING
    HENNEL, F
    NEDELEC, JF
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 520 - 524
  • [22] INTERLEAVED ECHO-PLANAR FLOW QUANTITATION
    MCKINNON, GC
    DEBATIN, JF
    WETTER, DR
    VONSCHULTHESS, GK
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) : 263 - 267
  • [23] Echo-planar MR imaging - Reply
    Edelman, RR
    RADIOLOGY, 1996, 198 (02) : 586 - 586
  • [24] Echo-planar imaging of the fetus and placenta
    Symonds, EM
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 519 - 521
  • [25] MULTIPLE BREATH-HOLD, INTERLEAVED, ECHO-PLANAR FLOW IMAGING
    SLAVIN, GS
    DEBBINS, JP
    RIEDERER, SJ
    RADIOLOGY, 1995, 197 : 391 - 391
  • [26] Determination of flow using half Fourier echo-planar MR imaging
    Rodríguez-González, AO
    REVISTA MEXICANA DE FISICA, 2000, 46 (02) : 177 - 189
  • [27] REAL-TIME FLOW MEASUREMENTS USING ECHO-PLANAR IMAGING
    GUILFOYLE, DN
    GIBBS, P
    ORDIDGE, RJ
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 1 - 8
  • [28] Analysis and correction of off-resonance artifacts in echo-planar cardiac diffusion tensor imaging
    van Gorkum, Robbert J. H.
    von Deuster, Constantin
    Guenthner, Christian
    Stoeck, Christian T.
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2561 - 2576
  • [29] Assessment of spectral ghost artifacts in echo-planar spectroscopic micro-imaging with flyback readout
    Weis, Jan
    Babos, Magor
    Estrada, Sergio
    Selvaraju, Ram Kumar
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [30] Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging
    Du, YPP
    Zhou, XHJ
    Bernstein, MA
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 509 - 515