Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging

被引:56
|
作者
Du, YPP
Zhou, XHJ
Bernstein, MA
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Psychiat & Radiol, Denver, CO 80262 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[3] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
关键词
concomitant magnetic field; Maxwell field; echo-planar imaging; phase correction;
D O I
10.1002/mrm.10249
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar images acquired in nonaxial planes are often distorted. Such image distortion has limited the applications of the echo-planar imaging (EPI) technique. In this article, it is demonstrated that a considerable amount of the distortion is caused by the higher-order magnetic field concomitant with the linear magnetic field gradient, or the concomitant magnetic field. The image distortion caused by the concomitant magnetic field is more prominent when a higher gradient amplitude is used for readout. It is also shown that the concomitant magnetic field can cause ghosting and blurring. A theoretical analysis is performed for the concomitant field effect in nonaxial EPI images. A point-by-point (or line-by-line) phase correction algorithm is developed to correct the image distortion, ghosting, and blurring. A postreconstruction processing algorithm is also developed to correct image distortion with much higher computational efficiency. Experimental results show that both correction methods effectively reduce the image distortion in coronal or sagittal images. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [1] Concomitant magnetic-field-induced artifacts in axial echo planar imaging
    Zhou, XHJ
    Du, YPP
    Bernstein, MA
    Reynolds, HG
    Maier, JK
    Polzin, JA
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 596 - 605
  • [2] Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging
    Holland, Dominic
    Kuperman, Joshua M.
    Dale, Anders M.
    NEUROIMAGE, 2010, 50 (01) : 175 - 183
  • [3] Image-based reduction of artifacts in multishot echo-planar imaging
    Hennel, F
    JOURNAL OF MAGNETIC RESONANCE, 1998, 134 (02) : 206 - 213
  • [4] Image-Based Reduction of Artifacts in Multishot Echo-Planar Imaging
    MR Centre, FORENAP, 68250 Rouffach, France
    J. Magn. Reson., 2 (206-213):
  • [5] Reducing flow artifacts in echo-planar imaging
    Pat, GTL
    Meyer, CH
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 436 - 447
  • [6] π Echo-Planar Imaging with concomitant field compensation for porous media MRI
    Xiao, Dan
    Balcom, Bruce J.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 260 : 38 - 45
  • [7] Artifacts induced by concomitant magnetic field in fast spin-echo imaging
    Applied Science Laboratory, GE Medical Systems, Milwaukee, WI, United States
    不详
    Magn. Reson. Med., 4 (582-591):
  • [8] Artifacts induced by concomitant magnetic field in fast spin-echo imaging
    Zhou, XJ
    Tan, SG
    Bernstein, MA
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) : 582 - 591
  • [10] Correction of Shearing Distortions in Echo-Planar Imaging
    Liu, Guoxiang
    Oshio, Koichi
    Ogawa, Seiji
    Murata, Tsutomu
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (07) : 2628 - 2634