Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging

被引:56
|
作者
Du, YPP
Zhou, XHJ
Bernstein, MA
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Psychiat & Radiol, Denver, CO 80262 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[3] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
关键词
concomitant magnetic field; Maxwell field; echo-planar imaging; phase correction;
D O I
10.1002/mrm.10249
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar images acquired in nonaxial planes are often distorted. Such image distortion has limited the applications of the echo-planar imaging (EPI) technique. In this article, it is demonstrated that a considerable amount of the distortion is caused by the higher-order magnetic field concomitant with the linear magnetic field gradient, or the concomitant magnetic field. The image distortion caused by the concomitant magnetic field is more prominent when a higher gradient amplitude is used for readout. It is also shown that the concomitant magnetic field can cause ghosting and blurring. A theoretical analysis is performed for the concomitant field effect in nonaxial EPI images. A point-by-point (or line-by-line) phase correction algorithm is developed to correct the image distortion, ghosting, and blurring. A postreconstruction processing algorithm is also developed to correct image distortion with much higher computational efficiency. Experimental results show that both correction methods effectively reduce the image distortion in coronal or sagittal images. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [21] Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field
    Yang, QX
    Wang, JL
    Smith', MB
    Meadowcroft, M
    Sun, XY
    Eslinger, PJ
    Golay, X
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1418 - 1423
  • [22] An optimized magnetic tissue tagging sequence for echo-planar imaging
    Al-Omari, F
    Chwialkowski, M
    Clarke, G
    Peshock, R
    11TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 1998, : 144 - 150
  • [23] On the synchronization of transcranial magnetic stimulation and functional echo-planar imaging
    Bestmann, S
    Baudewig, J
    Frahm, J
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 309 - 316
  • [24] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [25] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [26] Correction for eddy current induced Bo shifts in diffusion-weighted echo-planar imaging
    Calamante, F
    Porter, DA
    Gadian, DG
    Connelly, A
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 95 - 102
  • [27] Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging
    Zhao, Menglong
    Liu, Zhuang
    Sha, Yan
    Wang, Shenjiang
    Ye, Xinpei
    Pan, Yucheng
    Wang, Shaoyu
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 166 - 172
  • [28] Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI Using Reduced-Field-of-View Echo-Planar Imaging and Enhanced Reversed Polarity Gradient Method
    Rodriguez-Soto, Ana E.
    Fang, Lauren K.
    Holland, Dominic
    Zou, Jingjing
    Park, Helen H.
    Keenan, Kathryn E.
    Bartsch, Hauke
    Kuperman, Joshua
    Wallace, Anne M.
    Hahn, Michael
    Ojeda-Fournier, Haydee
    Dale, Anders M.
    Rakow-Penner, Rebecca
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (05) : 1581 - 1591
  • [29] Artifacts caused by transcranial magnetic stimulation coils and EEG electrodes in T2*-weighted echo-planar imaging
    Baudewig, J
    Paulus, W
    Frahm, J
    MAGNETIC RESONANCE IMAGING, 2000, 18 (04) : 479 - 484
  • [30] FETAL WEIGHT ESTIMATION BY ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING
    BAKER, PN
    JOHNSON, IR
    GOWLAND, PA
    HYKIN, J
    HARVEY, PR
    FREEMAN, A
    ADAMS, V
    WORTHINGTON, BS
    MANSFIELD, P
    LANCET, 1994, 343 (8898): : 644 - 645