Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging

被引:56
|
作者
Du, YPP
Zhou, XHJ
Bernstein, MA
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Psychiat & Radiol, Denver, CO 80262 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[3] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
关键词
concomitant magnetic field; Maxwell field; echo-planar imaging; phase correction;
D O I
10.1002/mrm.10249
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar images acquired in nonaxial planes are often distorted. Such image distortion has limited the applications of the echo-planar imaging (EPI) technique. In this article, it is demonstrated that a considerable amount of the distortion is caused by the higher-order magnetic field concomitant with the linear magnetic field gradient, or the concomitant magnetic field. The image distortion caused by the concomitant magnetic field is more prominent when a higher gradient amplitude is used for readout. It is also shown that the concomitant magnetic field can cause ghosting and blurring. A theoretical analysis is performed for the concomitant field effect in nonaxial EPI images. A point-by-point (or line-by-line) phase correction algorithm is developed to correct the image distortion, ghosting, and blurring. A postreconstruction processing algorithm is also developed to correct image distortion with much higher computational efficiency. Experimental results show that both correction methods effectively reduce the image distortion in coronal or sagittal images. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [31] ULTRAFAST MAGNETIC-RESONANCE SCANNING OF THE LIVER WITH ECHO-PLANAR IMAGING
    STEHLING, MK
    CHARNLEY, RM
    BLAMIRE, AM
    ORDIDGE, RJ
    COXON, R
    GIBBS, P
    HARDCASTLE, JD
    MANSFIELD, P
    BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (750): : 430 - 437
  • [32] Echo-planar magnetic resonance imaging of Gaviscon alginate rafts in humans
    Marciani, L
    Little, SL
    Coleman, NS
    Young, P
    Tyler, DJ
    Snee, J
    Jolliffe, IG
    Dettmar, PW
    Gowland, PA
    Spiller, RC
    GASTROENTEROLOGY, 2001, 120 (05) : A433 - A434
  • [33] UTERUS DIDELPHYS DEMONSTRATED WITH ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING
    BAKER, PN
    JOHNSON, IR
    ADAMS, V
    GOWLAND, PA
    MANSFIELD, P
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (03) : 813 - 814
  • [34] Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
    Jezzard, P
    Barnett, AS
    Pierpaoli, C
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (05) : 801 - 812
  • [35] An evaluation of the use of magnetic field maps to undistort echo-planar images
    Cusack, R
    Brett, M
    Osswald, K
    NEUROIMAGE, 2003, 18 (01) : 127 - 142
  • [36] IMAGE-RESTORATION FROM NONUNIFORM STATIC-FIELD INFLUENCE IN MODIFIED ECHO-PLANAR IMAGING
    SEKIHARA, K
    KOHNO, H
    MEDICAL PHYSICS, 1987, 14 (06) : 1087 - 1089
  • [37] Correction for eddy current induced B(o) shifts in diffusion-weighted echo-planar imaging
    Radiology and Physics Unit, Institute of Child Health, Univ. College London Medical School, London, United Kingdom
    不详
    Magn. Reson. Med., 1 (95-102):
  • [38] Correction of physiologically induced global off resonance effects in dynamic echo-planar and spiral functional imaging
    Pfeuffer, J
    Van de Moortele, PF
    Ugurbil, K
    Hu, XP
    Glover, GH
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) : 344 - 353
  • [39] Correction of B1 inhomogeneities using echo-planar imaging of water
    Thulborn, KR
    Boada, FE
    Shen, GX
    Christensen, JD
    Reese, TG
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 369 - 375
  • [40] Distortion correction in echo-planar imaging and quantitative T2* mapping
    Dierkes, T
    Neeb, H
    Shah, NJ
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 181 - 185