Motion artifact variability in biomagnetic wearable devices

被引:0
|
作者
Arekhloo, Negin Ghahremani [1 ,2 ]
Wang, Huxi [1 ,2 ]
Parvizi, Hossein [2 ]
Tanwear, Asfand [1 ]
Zuo, Siming [1 ]
McKinlay, Michael [2 ]
Nunez, Carlos Garcia [2 ]
Nazarpour, Kianoush [1 ,3 ]
Heidari, Hadi [1 ,2 ]
机构
[1] Neuranics Ltd, Glasgow, Scotland
[2] Univ Glasgow, James Watt Sch Engn, Microelect Lab, Glasgow City, Scotland
[3] Univ Edinburgh, Sch Informat, Edinburgh, Scotland
来源
基金
英国工程与自然科学研究理事会;
关键词
biomagnetic measurements; motion artifacts; wearable sensors; gradient background field; homogeneous background field; SIGNAL; ECG;
D O I
10.3389/fmedt.2024.1457535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Motion artifacts can be a significant noise source in biomagnetic measurements when magnetic sensors are not separated from the signal source. In ambient environments, motion artifacts can be up to ten times stronger than the desired signals, varying with environmental conditions. This study evaluates the variability of these artifacts and the effectiveness of a gradiometer in reducing them in such settings. To achieve these objectives, we first measured the single channel output in varying magnetic field conditions to observe the effect of homogeneous and gradient background fields. Our analysis revealed that the variability in motion artifact within an ambient environment is primarily influenced by the gradient magnetic field rather than the homogeneous one. Subsequently, we configured a gradiometer in parallel and vertical alignment with the direction of vibration (X-axis). Our findings indicated that in a gradient background magnetic field ranging from 1 nT/mm to 10 nT/mm, the single-channel sensor output exhibited a change of 164.97 pT per mm unit increase, while the gradiometer output showed a change of only 0.75 pT/mm within the same range. Upon repositioning the gradiometer vertically (Y direction), perpendicular to the direction of vibration, the single-channel output slope increased to 196.85 pT, whereas the gradiometer output only increased by 1.06 pT/mm for the same range. Our findings highlight the influence of ambient environments on motion artifacts and demonstrate the potential of gradiometers to mitigate these effects. In the future, we plan to record biomagnetic signals both inside and outside the shielded room to compare the efficacy of different gradiometer designs under varying environmental conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Motion tolerance in wearable sensors - The challenge of motion artifact
    Such, Olaf
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1542 - 1545
  • [2] Adaptive Cancellation of Motion Artifact in Wearable Biosensors
    Yousefi, Rasoul
    Nourani, Mehrdad
    Panahi, Issa
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2004 - 2008
  • [3] Motion Artifact Mitigation for Wearable Pulse Oximetry
    Williamson, James R.
    Patel, Tejash
    Singh, Ninoshka
    Siegel, Andrew
    Telfer, Brian
    Trebicka, Ray
    Welsh, Brendon
    Hoyt, Reed
    2018 IEEE 15TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI) AND THE WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2018, : 74 - 77
  • [4] Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope
    Lee, H.
    Chung, H.
    Lee, J.
    IEEE SENSORS JOURNAL, 2019, 19 (03) : 1166 - 1175
  • [5] Motion Artifact Reduction Algorithm in Wearable Healthcare System
    Lee, Seung Chul
    Kim, Sung Min
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [6] Challenge of motion artifact suppression in wearable monitoring solutions
    Such, Olaf
    Muehlsteff, Jens
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 49 - +
  • [7] Heart Rate Variability Analysis With Wearable Devices: Influence of Artifact Correction Method on Classification Accuracy for Emotion Recognition
    Cosoli, Gloria
    Poli, Angelica
    Scalise, Lorenzo
    Spinsante, Susanna
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [8] Biaxially-Stretchable Kirigami-Patterned Mesh Structures for Motion Artifact-Free Wearable Devices
    Lee, Hyo Chan
    Hsieh, Ezekiel Y.
    Nam, SungWoo
    2021 5TH IEEE ELECTRON DEVICES TECHNOLOGY & MANUFACTURING CONFERENCE (EDTM), 2021,
  • [9] Research and Application of Artifact Identification Method for Wearable ECG Devices
    Shangguan W.
    Li Y.
    Wu M.
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2021, 41 (06): : 665 - 670
  • [10] CycleGAN Based Motion Artifact Cancellation for Photoplethysmography Wearable Device
    Nguyen Mai Hoang Long
    Kim, Jong Jin
    Lee, Boon Giin
    Chung, Wan Young
    INTELLIGENT HUMAN COMPUTER INTERACTION, IHCI 2021, 2022, 13184 : 138 - 144