Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope

被引:52
|
作者
Lee, H. [1 ]
Chung, H. [1 ]
Lee, J. [1 ]
机构
[1] Wonkwang Univ, Coll Med, Dept Biomed Engn, Iksan 54538, South Korea
基金
新加坡国家研究基金会;
关键词
Accelerometer; gyroscope; motion artifacts; photoplethysmography; wearable device; REDUCTION; SIGNALS; FRAMEWORK; PPG; AGE;
D O I
10.1109/JSEN.2018.2879970
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wearable reflectance-type photoplethysmography (PPG) sensors, in the form of a band or watch, have recently gained significant attention for real-time heart rate (HR) monitoring applications. To accurately estimate the HR, even during intensive exercise, much effort has focused on simultaneously measured accelerometer signals that cancel out motion artifacts (MAs) from the PPG signal. However, the accelerometer does not always measure true MAs, as it measures not only the acceleration of motion but also gravitational acceleration corresponding to each axis of the accelerometer. In addition, the measured acceleration of the motion itself does not always coincide with the true motion. In this paper, we address the limitations of accelerometers and present an approach using a gyroscope to overcome the issues described. To the best of our knowledge, the limitations of the acceleration signals for MA cancellation have not been addressed in-depth. Here, we describe our developed wearable reflectance-type PPG sensor and compare the HR estimation performance between using a gyroscope and an accelerometer from 24 subjects. Our results showed that the gyroscope-assisted approach exhibited better performance than the accelerometer-assisted approach, especially for an exercise involving walking.
引用
收藏
页码:1166 / 1175
页数:10
相关论文
共 50 条
  • [1] CycleGAN Based Motion Artifact Cancellation for Photoplethysmography Wearable Device
    Nguyen Mai Hoang Long
    Kim, Jong Jin
    Lee, Boon Giin
    Chung, Wan Young
    INTELLIGENT HUMAN COMPUTER INTERACTION, IHCI 2021, 2022, 13184 : 138 - 144
  • [2] Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography
    Lee, Hooseok
    Chung, Heewon
    Ko, Hoon
    Parisi, Antonino
    Busacca, Alessandro
    Faes, Luca
    Pernice, Riccardo
    Lee, Jinseok
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 226
  • [3] Adaptive Cancellation of Motion Artifact in Wearable Biosensors
    Yousefi, Rasoul
    Nourani, Mehrdad
    Panahi, Issa
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2004 - 2008
  • [4] Motion Artifact Identification and Removal From Wearable Reflectance Photoplethysmography Using Piezoelectric Transducer
    Lee, Hooscok
    Chung, Heewon
    Kim, Jong-Woong
    Lee, Jinseok
    IEEE SENSORS JOURNAL, 2019, 19 (10) : 3861 - 3870
  • [5] Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography
    Han, Hyonyoung
    Kim, Min-Joon
    Kim, Jung
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1538 - +
  • [6] Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers
    Gibbs, PT
    Wood, LB
    Asada, HH
    Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 811 - 819
  • [7] Combining Nonlinear Adaptive Filtering and Signal Decomposition for Motion Artifact Removal in Wearable Photoplethysmography
    Ye, Yalan
    Cheng, Yunfei
    He, Wenwen
    Hou, Mengshu
    Zhang, Zhilin
    IEEE SENSORS JOURNAL, 2016, 16 (19) : 7133 - 7141
  • [8] Wearable Heart Rate Monitor Using Photoplethysmography for Motion
    Sudin, Sukhairi
    Aziz, Fezri
    Hishamuddin, Najwa Amanina Mohd
    Saad, Fathinul Syahir Ahmad
    Shakaff, Ali Yeon Md
    Zakaria, Ammar
    Salleh, Ahmad Faizal
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 1015 - 1018
  • [9] Noise cancellation model validation for reduced motion artifact wearable PPG sensors using MEMS accelerometers
    Wood, Levi B.
    Asada, H. Harry
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2628 - +
  • [10] Reducing motion artifact in wearable bio-sensors using MEMS accelerometers for active noise cancellation
    Gibbs, P
    Asada, HH
    ACC: Proceedings of the 2005 American Control Conference, Vols 1-7, 2005, : 1581 - 1586