Wearable reflectance-type photoplethysmography (PPG) sensors, in the form of a band or watch, have recently gained significant attention for real-time heart rate (HR) monitoring applications. To accurately estimate the HR, even during intensive exercise, much effort has focused on simultaneously measured accelerometer signals that cancel out motion artifacts (MAs) from the PPG signal. However, the accelerometer does not always measure true MAs, as it measures not only the acceleration of motion but also gravitational acceleration corresponding to each axis of the accelerometer. In addition, the measured acceleration of the motion itself does not always coincide with the true motion. In this paper, we address the limitations of accelerometers and present an approach using a gyroscope to overcome the issues described. To the best of our knowledge, the limitations of the acceleration signals for MA cancellation have not been addressed in-depth. Here, we describe our developed wearable reflectance-type PPG sensor and compare the HR estimation performance between using a gyroscope and an accelerometer from 24 subjects. Our results showed that the gyroscope-assisted approach exhibited better performance than the accelerometer-assisted approach, especially for an exercise involving walking.
引用
收藏
页码:1166 / 1175
页数:10
相关论文
共 50 条
  • [31] Artifact reduction in photoplethysmography
    Hayes, MJ
    Smith, PR
    APPLIED OPTICS, 1998, 37 (31): : 7437 - 7446
  • [32] FPGA based System for Blood Glucose Sensing using photoplethysmography and online motion artifact correction using Adaline
    Ramasahayam, Swathi
    Arora, Lavanya
    Chowdhury, Shubhajit Roy
    Anumukonda, MadhuBabu
    2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 22 - 27
  • [33] Motion Artifact Reduction Algorithm in Wearable Healthcare System
    Lee, Seung Chul
    Kim, Sung Min
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [34] Challenge of motion artifact suppression in wearable monitoring solutions
    Such, Olaf
    Muehlsteff, Jens
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 49 - +
  • [35] Reduction of Motion Artifacts From Remote Photoplethysmography Using Adaptive Noise Cancellation and Modified HSI Model
    Cho, Dongrae
    Kim, Jongin
    Lee, Kwang Jin
    Kim, Sayup
    IEEE ACCESS, 2021, 9 (09): : 122655 - 122667
  • [36] Motion Artifact Cancellation of Seismocardiographic Recording From Moving Subjects
    Yang, Chenxi
    Tavassolian, Negar
    IEEE SENSORS JOURNAL, 2016, 16 (14) : 5702 - 5708
  • [37] Dual-electrode motion artifact cancellation for mobile electroencephalography
    Nordin, Andrew D.
    Hairston, W. David
    Ferris, Daniel P.
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (05)
  • [38] Active Contours: An overview with applications to motion artifact cancellation in MRI
    Guidry, DL
    Farag, AA
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 644 - 647
  • [39] MRI artifact cancellation due to rigid motion in the imaging plane
    Zoroofi, RA
    Sato, Y
    Tamura, S
    Naito, H
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (06) : 768 - 784
  • [40] Active Contours: An overview with applications to motion artifact cancellation in MRI
    Guidry, Diana L.
    Farag, Aly A.
    ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing - Proceedings, 1999, 6 : 3425 - 3428