Motion artifact variability in biomagnetic wearable devices

被引:0
|
作者
Arekhloo, Negin Ghahremani [1 ,2 ]
Wang, Huxi [1 ,2 ]
Parvizi, Hossein [2 ]
Tanwear, Asfand [1 ]
Zuo, Siming [1 ]
McKinlay, Michael [2 ]
Nunez, Carlos Garcia [2 ]
Nazarpour, Kianoush [1 ,3 ]
Heidari, Hadi [1 ,2 ]
机构
[1] Neuranics Ltd, Glasgow, Scotland
[2] Univ Glasgow, James Watt Sch Engn, Microelect Lab, Glasgow City, Scotland
[3] Univ Edinburgh, Sch Informat, Edinburgh, Scotland
来源
基金
英国工程与自然科学研究理事会;
关键词
biomagnetic measurements; motion artifacts; wearable sensors; gradient background field; homogeneous background field; SIGNAL; ECG;
D O I
10.3389/fmedt.2024.1457535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Motion artifacts can be a significant noise source in biomagnetic measurements when magnetic sensors are not separated from the signal source. In ambient environments, motion artifacts can be up to ten times stronger than the desired signals, varying with environmental conditions. This study evaluates the variability of these artifacts and the effectiveness of a gradiometer in reducing them in such settings. To achieve these objectives, we first measured the single channel output in varying magnetic field conditions to observe the effect of homogeneous and gradient background fields. Our analysis revealed that the variability in motion artifact within an ambient environment is primarily influenced by the gradient magnetic field rather than the homogeneous one. Subsequently, we configured a gradiometer in parallel and vertical alignment with the direction of vibration (X-axis). Our findings indicated that in a gradient background magnetic field ranging from 1 nT/mm to 10 nT/mm, the single-channel sensor output exhibited a change of 164.97 pT per mm unit increase, while the gradiometer output showed a change of only 0.75 pT/mm within the same range. Upon repositioning the gradiometer vertically (Y direction), perpendicular to the direction of vibration, the single-channel output slope increased to 196.85 pT, whereas the gradiometer output only increased by 1.06 pT/mm for the same range. Our findings highlight the influence of ambient environments on motion artifacts and demonstrate the potential of gradiometers to mitigate these effects. In the future, we plan to record biomagnetic signals both inside and outside the shielded room to compare the efficacy of different gradiometer designs under varying environmental conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Real time data evaluation with wearable devices: An Impact of Artifact Calibration Method on Emotion Recognition
    Fayaz, Fayaz Ahmad
    Malik, Arun
    2021 INTERNATIONAL CONFERENCE ON COMPUTING SCIENCES (ICCS 2021), 2021, : 152 - 155
  • [42] Motion Artifact Removal in Ambulatory ECG Signal for Heart Rate Variability Analysis
    Berwal, Deepak
    Vandana, C. R.
    Dewan, Sourya
    Jiji, C., V
    Baghini, Maryam Shojaei
    IEEE SENSORS JOURNAL, 2019, 19 (24) : 12432 - 12442
  • [43] The importance of physiological data variability in wearable devices for digital health applications
    Cosoli, Gloria
    Poli, Angelica
    Spinsante, Susanna
    Scalise, Lorenzo
    ACTA IMEKO, 2022, 11 (02):
  • [44] A SMART SENSING MODULE AIMS AT REDUCTION OF MOTION ARTIFACT FOR WEARABLE TONOMETRY BLOOD PRESSURE DEVICE
    Liu, Weiting
    Zhu, Tao
    Xie, Fuyuan
    Zhan, Binpeng
    Xu, Man
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E87 - E87
  • [45] Motion Artifact Removal for Wearable ECG Using Stationary Wavelet Multi-resolution Analysis
    Nagai, Shuto
    Anzai, Daisuke
    Wang, Jianqing
    2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC-BEIJING), 2017,
  • [46] Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
    Lee, Jongshill
    Kim, Minseong
    Park, Hoon-Ki
    Kim, In Young
    SENSORS, 2020, 20 (05)
  • [47] A Micropower Motion Artifact Estimator for Input Dynamic Range Reduction in Wearable ECG Acquisition Systems
    Pholpoke, Bhirawich
    Songthawornpong, Techapon
    Wattanapanitch, Woradorn
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (05) : 1021 - 1035
  • [48] A NOVEL METHOD FOR MOTION ARTIFACT REMOVAL IN WEARABLE PPG SENSORS BASED ON BLIND SOURCE SEPARATION
    Pflugradt, Maik
    Rose, Marcus
    Orglmeister, Reinhold
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [49] Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers
    Gibbs, PT
    Wood, LB
    Asada, HH
    Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 811 - 819
  • [50] Investigating the possible effect of electrode support structure on motion artifact in wearable bioelectric signal monitoring
    Alper Cömert
    Jari Hyttinen
    BioMedical Engineering OnLine, 14