Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection

被引:0
|
作者
Viriyasaranon, Thanaporn [1 ,4 ]
Ma, Serie [2 ]
Thies, Mareike [3 ]
Maier, Andreas [3 ]
Choi, Jang-Hwan [1 ,4 ]
机构
[1] Ewha Womans Univ, Dept Artificial Intelligence, Seoul 03760, South Korea
[2] Ewha Womans Univ, Grad Program Syst Hlth Sci & Engn, Div Mech & Biomed Engn, Seoul 03760, South Korea
[3] Friedrich Alexander Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91054 Erlangen, Germany
[4] Ewha Womans Univ, Dept Computat Med, Grad Program Syst Hlth Sci & Engn, Seoul 03760, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT; Motion artifacts; Multitask learning; Unsupervised learning; Hybrid transformer-CNN; Anatomical landmark detection; Multiresolution heatmap learning; Dynamic landmark motion estimation;
D O I
10.1016/j.eswa.2025.127258
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Motion artifacts in cone-beam computed tomography (CBCT) primarily result from patient movement during the scanning process, which can compromise diagnostic accuracy. Emerging deep learning-based techniques have shown promise in mitigating these artifacts; however, they often rely on motion-free CBCT reconstructions for training, which poses practical challenges in clinical settings. An alternative approach involves leveraging the positions of metallic fiducial markers for motion estimation. While effective, this method is time-intensive and requires additional equipment installation, limiting its practicality. To address these challenges, we propose the Dynamic Landmark Motion Estimation (DLME) method, designed to reduce high-frequency noise and errors in landmark detection, thereby enhancing image quality. DLME is powered by the proposed TriForceNet, a novel landmark detection framework that integrates a sequential hybrid transformer-convolutional neural network architecture, multiresolution heatmap learning, and a multitask learning strategy augmented with an auxiliary segmentation head to improve motion estimation accuracy. Experimental evaluations demonstrate that TriForceNet achieves superior performance compared to state-of-the-art landmark detectors on twodimensional projection images from the 4D extended cardiac-torso head phantom (XCAT) dataset, real patient CT scans from the CQ500 dataset, and knee regions from the CT scans in the VSD full body dataset. Furthermore, the DLME methodology outperforms traditional unsupervised motion compensation techniques and surpasses supervised, image-based motion artifact reduction methods across these datasets. The source code for the proposed model is publicly available at https://github.com/Thanaporn09/TriForceNet.git.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Cupping artifacts analysis and correction for a FPD-based cone-beam CT
    Zhang Li
    Gao Hewei
    Li Shuanglei
    Chen Zhiqiang
    Xing Yuxiang
    COMPUTATIONAL IMAGING IV, 2006, 6065
  • [42] Streaking Artifacts Reduction in Four-Dimensional Cone-Beam Computed Tomography
    Leng, S.
    Zambelli, J.
    Tolakanahalli, R.
    Nett, B.
    Munro, P.
    Star-Lack, J.
    Paliwal, B.
    Chen, G.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [43] Streaking artifacts reduction in four-dimensional cone-beam computed tomography
    Leng, Shuai
    Zambelli, Joseph
    Tolakanahalli, Ranjini
    Nett, Brian
    Munro, Peter
    Star-Lack, Joshua
    Paliwal, Bhudatt
    Chena, Guang-Hong
    MEDICAL PHYSICS, 2008, 35 (10) : 4649 - 4659
  • [44] 4-D Cone-Beam CT Reconstruction via Diffusion Model and Motion Compensation
    Wang, Xianghong
    Ou, Zhengwei
    Jin, Peng
    Xie, Jiayi
    Teng, Ze
    Xu, Lei
    Du, Jichen
    Ding, Mingchao
    Chen, Yang
    Niu, Tianye
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (02) : 191 - 201
  • [45] Reduction of ring artifacts in cone beam CT: Artifact detection and correction for flat panel imagers
    Altunbas, M.
    Shaw, C.
    Chen, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2287 - 2288
  • [46] Metal Artifact Reduction in Cone-beam CT by Constrained Optimization
    Zhang, X.
    Wang, J.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S652 - S652
  • [47] Imaging artifacts of Onyx and PHIL on conventional CT, cone-beam CT and MRI in an animal model
    Vollherbst, Dominik F.
    Otto, Ruth
    Do, Thuy
    Kauczor, Hans U.
    Bendszus, Martin
    Sommer, Christof M.
    Moehlenbruch, Markus A.
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (06) : 693 - 701
  • [48] Quantitative Evaluation of Metal Artifacts in CT and Cone-Beam CT Images On the Accuracy of Dose Calculation
    Oyewale, S.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3825 - 3825
  • [49] Removing ring artifacts in cone-beam CT via TV-Stokes and unidirectional total variation model
    Wu, Huantang
    Li, Jianwu
    Wang, Hong
    MEDICAL PHYSICS, 2019, 46 (04) : 1719 - 1727
  • [50] A Deep Unsupervised Learning Model for Artifact Correction of Pelvis Cone-Beam CT
    Dong, Guoya
    Zhang, Chenglong
    Liang, Xiaokun
    Deng, Lei
    Zhu, Yulin
    Zhu, Xuanyu
    Zhou, Xuanru
    Song, Liming
    Zhao, Xiang
    Xie, Yaoqin
    FRONTIERS IN ONCOLOGY, 2021, 11