4-D Cone-Beam CT Reconstruction via Diffusion Model and Motion Compensation

被引:0
|
作者
Wang, Xianghong [1 ]
Ou, Zhengwei [2 ,3 ]
Jin, Peng [1 ]
Xie, Jiayi [4 ,5 ]
Teng, Ze [4 ,6 ]
Xu, Lei [3 ,7 ]
Du, Jichen [8 ]
Ding, Mingchao [8 ]
Chen, Yang [9 ,10 ]
Niu, Tianye [3 ,8 ]
机构
[1] Inst Biomed Engn, Shenzhen Bay Lab, Shenzhen 518107, Peoples R China
[2] Southeast Univ, Coll Software Engn, Nanjing 210096, Peoples R China
[3] Shenzhen Bay Lab, Shenzhen 518107, Peoples R China
[4] Peking Univ, Hosp 3, Dept Radiol, Beijing 100191, Peoples R China
[5] Tsinghua Univ, Dept Automat, Beijing 100084, Peoples R China
[6] Chinese Acad Med Sci, Natl Canc Ctr, Natl Clin Res Ctr Canc, Dept Radiol,Canc Hosp,Peking Union Med Coll, Beijing 100006, Peoples R China
[7] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiat Oncol, Xian 710061, Peoples R China
[8] Peking Univ, Aerosp Ctr Hosp, Aerosp Sch Clin Med, Beijing 100049, Peoples R China
[9] Southeast Univ, Lab Image Sci & Technol, Nanjing 210096, Peoples R China
[10] Ctr Rech Informat Biomed SinoFrancais, F-35042 Rennes, France
基金
北京市自然科学基金;
关键词
Image reconstruction; Biomedical imaging; Accuracy; Three-dimensional displays; Diffusion models; Computed tomography; Standards; 4-D cone-beam computed tomography (4-D CBCT); deep learning; motion compensation (MoCo); sparse-view CT reconstruction;
D O I
10.1109/TRPMS.2024.3449155
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
4-Dcone-beam computed tomography (4-D CBCT) has recently been recognized as a proficient technique in mitigating motion artifacts attributed to respiratory organ movement. The primary challenges in 4-D CBCT reconstruction encompass the precision in projection grouping, the efficacy in reconstructing from sparsely sampled data, and the accuracy in deformation field estimation. To surmount these challenges, we propose an innovative approach that integrates meticulous respiratory curve extraction for projection grouping and utilizes a diffusion model network with motion compensation (MoCo) techniques targeted at significantly enhancing image quality. An object detection network is employed to ascertain the exact position of the diaphragm, which is then normalized to formulate the respiratory curve. Further, we employ a U-Net architecture-based diffusion model, which integrates attention mechanisms to enhance sparse-view reconstruction and reduce artifacts through Guided-Diffusion. Deviating from conventional optical flow methods, our approach introduces an unsupervised registration network for deformation vector field (DVF) in phase-enhanced images. This DVF is then utilized in a motion-compensated, ordered-subset, simultaneous algebraic reconstruction technique, culminating in the generation of 4-D CBCT images. The efficacy of this method has been substantiated through validation on both simulated and clinical datasets, with the results from comparative experiments indicating promising outcomes.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [1] Directional Interpolation for Motion Weighted 4D Cone-Beam CT Reconstruction
    Zhang, Hua
    Sonke, Jan-Jakob
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 181 - 188
  • [2] Deformable motion compensation for interventional cone-beam CT
    Capostagno, S.
    Sisniega, A.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C. R.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [3] 4D Cone-beam CT reconstruction using a motion model based on principal component analysis
    Staub, David
    Docef, Alen
    Brock, Robert S.
    Vaman, Constantin
    Murphy, Martin J.
    MEDICAL PHYSICS, 2011, 38 (12) : 6697 - 6709
  • [4] Motion Vector Field Upsampling for Improved 4D Cone-Beam CT Motion Compensation of the Thorax
    Sauppe, Sebastian
    Rank, Christopher M.
    Brehm, Marcus
    Paysan, Pascal
    Seghers, Dieter
    Kachelriess, Marc
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [5] Motion compensation for cone-beam CT based on 4D motion field of sinogram tracked markers
    Schäfer, D
    Bertram, M
    Conrads, N
    Wiegert, J
    Rose, G
    Rasche, V
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 189 - 194
  • [6] Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
    Wang, Jing
    Gu, Xuejun
    MEDICAL PHYSICS, 2013, 40 (10)
  • [7] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-Beam CT
    Wang, J.
    Gu, X.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [10] Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction
    Zhang, Hua
    Kruis, Matthijs
    Sonke, Jan-Jakob
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2254 - 2275