Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection

被引:0
|
作者
Viriyasaranon, Thanaporn [1 ,4 ]
Ma, Serie [2 ]
Thies, Mareike [3 ]
Maier, Andreas [3 ]
Choi, Jang-Hwan [1 ,4 ]
机构
[1] Ewha Womans Univ, Dept Artificial Intelligence, Seoul 03760, South Korea
[2] Ewha Womans Univ, Grad Program Syst Hlth Sci & Engn, Div Mech & Biomed Engn, Seoul 03760, South Korea
[3] Friedrich Alexander Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91054 Erlangen, Germany
[4] Ewha Womans Univ, Dept Computat Med, Grad Program Syst Hlth Sci & Engn, Seoul 03760, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT; Motion artifacts; Multitask learning; Unsupervised learning; Hybrid transformer-CNN; Anatomical landmark detection; Multiresolution heatmap learning; Dynamic landmark motion estimation;
D O I
10.1016/j.eswa.2025.127258
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Motion artifacts in cone-beam computed tomography (CBCT) primarily result from patient movement during the scanning process, which can compromise diagnostic accuracy. Emerging deep learning-based techniques have shown promise in mitigating these artifacts; however, they often rely on motion-free CBCT reconstructions for training, which poses practical challenges in clinical settings. An alternative approach involves leveraging the positions of metallic fiducial markers for motion estimation. While effective, this method is time-intensive and requires additional equipment installation, limiting its practicality. To address these challenges, we propose the Dynamic Landmark Motion Estimation (DLME) method, designed to reduce high-frequency noise and errors in landmark detection, thereby enhancing image quality. DLME is powered by the proposed TriForceNet, a novel landmark detection framework that integrates a sequential hybrid transformer-convolutional neural network architecture, multiresolution heatmap learning, and a multitask learning strategy augmented with an auxiliary segmentation head to improve motion estimation accuracy. Experimental evaluations demonstrate that TriForceNet achieves superior performance compared to state-of-the-art landmark detectors on twodimensional projection images from the 4D extended cardiac-torso head phantom (XCAT) dataset, real patient CT scans from the CQ500 dataset, and knee regions from the CT scans in the VSD full body dataset. Furthermore, the DLME methodology outperforms traditional unsupervised motion compensation techniques and surpasses supervised, image-based motion artifact reduction methods across these datasets. The source code for the proposed model is publicly available at https://github.com/Thanaporn09/TriForceNet.git.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Cone-beam CT landmark detection for measuring basal bone width: a retrospective validation study
    Dai, Juan
    Guo, Xinge
    Zhang, Hongyuan
    Xie, Haoyu
    Huang, Jiahui
    Huang, Qiangtai
    Huang, Bingsheng
    BMC ORAL HEALTH, 2024, 24 (01):
  • [22] Deformable motion compensation for interventional cone-beam CT
    Capostagno, S.
    Sisniega, A.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C. R.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [23] Artifacts Reduction Method for Phase-resolved Cone-Beam CT (CBCT) Images via a Prior-Guided CNN
    Zhi, Shaohua
    Duan, Jiayu
    Cai, Jianmei
    Mou, Xuanqin
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [24] Two methods for reducing moving metal artifacts in cone-beam CT
    Hahn, Andreas
    Knaup, Michael
    Brehm, Marcus
    Sauppe, Sebastian
    Kachelriess, Marc
    MEDICAL PHYSICS, 2018, 45 (08) : 3671 - 3680
  • [25] An energy minimization method for the correction of cupping artifacts in cone-beam CT
    Xie, Shipeng
    Zhuang, Wenqin
    Li, Haibo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 307 - 319
  • [26] Dependence of cone-beam CT artifacts on the frequency content of the imaged object
    Jaffray, D
    Clackdoyle, R
    Siewerdsen, J
    Noo, F
    MEDICAL PHYSICS, 2003, 30 (06) : 1407 - 1407
  • [27] Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
    Kearney, V.
    Gu, X.
    Chen, S.
    Jiang, L.
    Liu, H.
    Chiu, T.
    Yordy, J.
    Nedzi, L.
    Mao, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 500 - 500
  • [28] Reduction of aliasing artifacts in cone-beam CT images using data derivatives with respect to detector coordinates
    Zou, Y
    Pan, X
    Jiang, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820
  • [29] Phantom development for artifact reduction in cone-beam CT
    Keely, A.
    Kyprianou, I.
    Jennings, R.
    Myers, K.
    Gilat-Schmidt, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2340 - 2340
  • [30] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)