Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection

被引:0
|
作者
Viriyasaranon, Thanaporn [1 ,4 ]
Ma, Serie [2 ]
Thies, Mareike [3 ]
Maier, Andreas [3 ]
Choi, Jang-Hwan [1 ,4 ]
机构
[1] Ewha Womans Univ, Dept Artificial Intelligence, Seoul 03760, South Korea
[2] Ewha Womans Univ, Grad Program Syst Hlth Sci & Engn, Div Mech & Biomed Engn, Seoul 03760, South Korea
[3] Friedrich Alexander Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91054 Erlangen, Germany
[4] Ewha Womans Univ, Dept Computat Med, Grad Program Syst Hlth Sci & Engn, Seoul 03760, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT; Motion artifacts; Multitask learning; Unsupervised learning; Hybrid transformer-CNN; Anatomical landmark detection; Multiresolution heatmap learning; Dynamic landmark motion estimation;
D O I
10.1016/j.eswa.2025.127258
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Motion artifacts in cone-beam computed tomography (CBCT) primarily result from patient movement during the scanning process, which can compromise diagnostic accuracy. Emerging deep learning-based techniques have shown promise in mitigating these artifacts; however, they often rely on motion-free CBCT reconstructions for training, which poses practical challenges in clinical settings. An alternative approach involves leveraging the positions of metallic fiducial markers for motion estimation. While effective, this method is time-intensive and requires additional equipment installation, limiting its practicality. To address these challenges, we propose the Dynamic Landmark Motion Estimation (DLME) method, designed to reduce high-frequency noise and errors in landmark detection, thereby enhancing image quality. DLME is powered by the proposed TriForceNet, a novel landmark detection framework that integrates a sequential hybrid transformer-convolutional neural network architecture, multiresolution heatmap learning, and a multitask learning strategy augmented with an auxiliary segmentation head to improve motion estimation accuracy. Experimental evaluations demonstrate that TriForceNet achieves superior performance compared to state-of-the-art landmark detectors on twodimensional projection images from the 4D extended cardiac-torso head phantom (XCAT) dataset, real patient CT scans from the CQ500 dataset, and knee regions from the CT scans in the VSD full body dataset. Furthermore, the DLME methodology outperforms traditional unsupervised motion compensation techniques and surpasses supervised, image-based motion artifact reduction methods across these datasets. The source code for the proposed model is publicly available at https://github.com/Thanaporn09/TriForceNet.git.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Cone-beam CT reconstruction with gravity-induced motion
    Shieh, Chun-Chien
    Barber, Jeffrey
    Counter, William
    Sykes, Jonathan
    Bennett, Peter
    Heng, Soo-Min
    White, Paul
    Corde, Stephanie
    Jackson, Michael
    Ahern, Verity
    Feain, Ilana
    O'Brien, Ricky
    Keall, Paul J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (20):
  • [32] Motion Estimation Using Cone-Beam CT Projection Images
    Becker, N.
    Kay, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [33] Cone-Beam CT Reconstruction with Gravity-Induced Motion
    Shieh, C.
    Barber, J.
    Counter, W.
    Sykes, J.
    Bennett, P.
    Heng, S.
    White, P.
    Downes, S.
    Jackson, M.
    Keall, P.
    Feain, I.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [34] Comparison of Supervised and Unsupervised Approaches for the Generation of Synthetic CT from Cone-Beam CT
    Rossi, Matteo
    Cerveri, Pietro
    DIAGNOSTICS, 2021, 11 (08)
  • [35] Enhanced 4D cone-beam CT with inter-phase motion model
    Li, Tianfang
    Koong, Albert
    Xing, Lei
    MEDICAL PHYSICS, 2007, 34 (09) : 3688 - 3695
  • [36] Reduction of cone-beam CT artifacts in a robotic CBCT device using saddle trajectories with integrated infrared tracking
    Wei, Chengtao
    Albrecht, Johanna
    Rit, Simon
    Laurendeau, Matthieu
    Thummerer, Adrian
    Corradini, Stefanie
    Belka, Claus
    Steininger, Philipp
    Ginzinger, Felix
    Kurz, Christopher
    Riboldi, Marco
    Landry, Guillaume
    MEDICAL PHYSICS, 2024, 51 (03) : 1674 - 1686
  • [37] The effect of MV cone-beam CT cupping artifacts on dose calculation accuracy
    Chen, J
    Morin, O
    Chen, H
    Aubin, M
    Pouliot, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1936 - 1936
  • [38] Iterative Image-Domain Ring Artifacts Removal in Cone-Beam CT
    Liang, X.
    Zhang, Z.
    Yu, S.
    Wu, S.
    Li, Z.
    Xie, Y.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [39] Effects of cone-beam CT noise and cupping artifacts on deformable image registration
    Murphy, M.
    Lu, L.
    Crimaldi, A.
    Cuttino, L.
    Shield, C.
    Keall, P.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1996 - 1996
  • [40] Reducing metal artifacts in cone-beam CT images by preprocessing projection data
    Zhang, Yongbin
    Zhang, Lifei
    Zhu, Ronald
    Lee, Andrew K.
    Chambers, Mark
    Dong, Lei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 924 - 932