Evaluation of dynamic accuracy and latency of a surface-guided radiotherapy system

被引:0
|
作者
Yamauchi, Ryohei [1 ]
Tomita, Fumihiro [1 ]
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, 9-1 Akashi Cho,Chuo Ku, Tokyo 1048560, Japan
关键词
Surface-guided radiotherapy; Respiratory motion; Dynamic accuracy; Latency; RADIATION-THERAPY; QUALITY-ASSURANCE;
D O I
10.1007/s12194-024-00866-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study is to evaluate the dynamic accuracy and latency of the surface-guided radiotherapy (SGRT) system using TrueBeam and AlignRT in compliance with SGRT guidelines. Beam characteristics-flatness, symmetry, beam quality, and output-were compared between gated and nongated beams using a two-dimensional ionization chamber array and a Farmer-type chamber. Dynamic accuracy was assessed using a moving platform and breast phantom, with measurements taken for various shift values (5, 10, 30 mm), region-of-interest (ROI) shapes, reference-surface image types (DICOM and capture), surface resolutions, and room illuminations. Latency due to differences in frame rates was evaluated using radiochromic film, calculated from position displacements of profiles at two speeds. Differences in beam characteristics between gated and nongated beams were within 0.1%. Dynamic accuracy showed minimal dependence on settings, with deviations of < 1 mm for a 10-mm shift. A maximum displacement of 1.9 mm was observed with a 30-mm shift at the body ROI. Beam-on latency at 12, 16, 25, and 35 frames per second was 253.2 +/- 21.9, 225.7 +/- 33.7, 177.1 +/- 43.0, and 112.4 +/- 29.2 ms, respectively, with similar trends for beam-off latency. This study is the first to evaluate the dynamic accuracy of the TrueBeam and AlignRT system under SGRT-specific settings. While accuracy was generally maintained (< 1 mm), ROI shape significantly impacted results. Latency results indicate that certain frame rates may not meet guideline limits, underscoring the need for careful SGRT system use in clinical applications.
引用
收藏
页码:136 / 146
页数:11
相关论文
共 50 条
  • [31] Evaluation of the Tibiofemoral Contact Characteristics of a Customized Surface-Guided Knee Implant
    Pejhan, Shabnam
    Khosravipour, Ida
    Gascoyne, Trevor
    Bohm, Eric
    Brandt, Jan-Mels
    Luo, Yunhua
    Wyss, Urs
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (02) : 205 - 212
  • [32] Dosimetric Impact of the Interplay Effect for Abdominal Cancer Patients Using Surface-Guided Radiotherapy
    Xu, H.
    Wang, J.
    Lu, S.
    Hu, W.
    MEDICAL PHYSICS, 2019, 46 (06) : E382 - E382
  • [33] Surface-Guided Formation of an Organocobalt Complex
    Weber, Peter B.
    Hellwig, Raphael
    Paintner, Tobias
    Lattelais, Marie
    Paszkiewicz, Mateusz
    Aguilar, Pablo Casado
    Deimel, Peter S.
    Guo, Yuanyuan
    Zhang, Yi-Qi
    Allegretti, Francesco
    Papageorgiou, Anthoula C.
    Reichert, Joachim
    Klyatskaya, Svetlana
    Ruben, Mario
    Barth, Johannes V.
    Bocquet, Marie-Laure
    Klappenberger, Florian
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (19) : 5754 - 5759
  • [34] Accuracy of Patient Setup in Breast Cancer Radiation Therapy Using Cone Beam Computed Tomography and Surface-Guided Radiotherapy - A Comparative Analysis
    Vivekanandan, A.
    Chaudhary, S.
    Aashita, A.
    Amritt, A.
    Ghosh, A.
    Dagar, A.
    Maiti, A.
    Hazarika, S.
    Raj, J.
    Sharma, A.
    Kamboj, K.
    Kumar, A.
    Sharma, J.
    Sharma, D. N.
    Mallick, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E195 - E196
  • [35] Letter to the Editor: reply to "Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy"
    Robinson, Adi
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (07) : 642 - 643
  • [36] Accuracy and potential improvements of surface-guided breast cancer radiotherapy in deep inspiration breath-hold with daily image-guidance
    Nankali, Saber
    Hansen, Rune
    Worm, Esben
    Yates, Esben S.
    Thomsen, Mette Skovhus
    Offersen, Birgitte
    Poulsen, Per Rugaard
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (19):
  • [37] Evaluation of the Tibiofemoral Contact Characteristics of a Customized Surface-Guided Knee Implant
    Shabnam Pejhan
    Ida Khosravipour
    Trevor Gascoyne
    Eric Bohm
    Jan-Mels Brandt
    Yunhua Luo
    Urs Wyss
    Journal of Medical and Biological Engineering, 2019, 39 : 205 - 212
  • [38] Performance assessment of the surface-guided radiation therapy system: Varian Identify
    Ayrancioglu, Oguzhan
    Ayrancioglu, Ceren
    Arikan, Serife Ceren
    Alicikus, Lutfiye Zumre Arican
    MEDICAL DOSIMETRY, 2024, 49 (03) : 222 - 228
  • [39] Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience
    Penninkhof, Joan
    Fremeijer, Kimm
    Harten, Kirsten Offereins-van
    van Wanrooij, Cynthia
    Quint, Sandra
    Kunnen, Britt
    Hoffmans-Holtzer, Nienke
    Swaak, Annemarie
    Baaijens, Margreet
    Dirkx, Maarten
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 21 : 51 - 57
  • [40] Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance-guided radiotherapy system
    Nakayama, Hiroki
    Okamoto, Hiroyuki
    Nakamura, Satoshi
    Iijima, Kotaro
    Chiba, Takahito
    Takemori, Mihiro
    Nakaichi, Tetsu
    Mikasa, Shohei
    Fujii, Kyohei
    Sakasai, Tatsuya
    Kuwahara, Junichi
    Miura, Yuki
    Fujiyama, Daisuke
    Tsunoda, Yuki
    Hanzawa, Takuma
    Igaki, Hiroshi
    Chang, Weishan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):