Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications

被引:0
|
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
De Bortoli Jr, Nilton [4 ]
Mello, Bruno Freitas [5 ]
Piattelli, Adriano [6 ,7 ]
Mijiritsky, Eitan [8 ,9 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Politecn Bari Univ, Dept Mech Math & Management, I-70125 Bari, Italy
[2] G dAnnunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, I-66100 Chieti, Italy
[4] Assoc Paulista Cirurgioes Dent APCD, Dept Oral Implantol, BR-02011000 Sao Bernardo Do Campo, Brazil
[5] Univ Vale Itajai, Dept Periodont & Implant Dent, BR-88302901 Itajai, Brazil
[6] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[7] UCAM Univ Catolica San Antonio Murcia, Fac Med, Murcia 30107, Spain
[8] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sch Med, Dept Head & Neck Surg & Maxillofacial Surg, IL-64239 Tel Aviv, Israel
[9] Tel Aviv Univ, Fac Med, Goldschleger Sch Dent Med, IL-39040 Tel Aviv, Israel
关键词
finite element analysis (FEA); dental implants; dental stress analysis; short implants; angled implants; inclined abutments; MACHINED-SURFACE IMPLANTS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; AUGMENTED BONE; DIAMETER; TOOTH; QUALITY; CONNECTIONS; RESORPTION; GEOMETRY;
D O I
10.3390/ma17235680
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.5, and 3 mm, corresponding to Bergkvist's classifications IV, III, and II, respectively. A simplified 3D model of the bone was developed for the analysis. Two short implants were inserted into the model: one with a 30 degrees inclined abutment (IA) and another positioned at a 30 degrees angle featuring a straight abutment (II). A vertical force (120 N) was applied to the upper surface of the abutments. FEA software was employed to assess the stresses on the peri-implant tissues and the implants. The findings indicated that a reduction in cortical bone thickness results in an increase in stress within the cortical bone. For IA, the stresses recorded 32.56, 56.12, and 96.14 MPa for cortical thicknesses of 3, 1.5, and 0.5 mm, respectively. Conversely, II exhibited increased stresses across all bone qualities (52.32, 76.15, and 126.32 MPa for the same cortical thicknesses). It is advisable to avoid II in cases of poor bone quality and thin cortical due to the heightened risk of overload-induced bone resorption; however, it may be preferable to use IA in scenarios involving good bone quality and thicker cortical.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] A biomechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model
    Omori, Miyuki
    Sato, Yuji
    Kitagawa, Noboru
    Shimura, Yuta
    Ito, Manabu
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2015, 1 (01):
  • [42] BIOMECHANICAL EVALUATION OF MANDIBULAR OVERDENTURES SUPPORTED BY MINI-IMPLANTS: A FINITE ELEMENT ANALYSIS
    Ganesh, Thiagarajan
    Scully, Jessica
    Walker, Mary P.
    Petrie, Cynthia S.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (06)
  • [43] Effects of crown retrieval on implants and the surrounding bone: a finite element analysis
    Ozkir, Serhat Emre
    Unal, Server Mutluay
    Yurekli, Emel
    Guven, Sedat
    JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (02): : 131 - 136
  • [44] Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis
    Kitamura, E
    Stegaroiu, R
    Nomura, S
    Miyakawa, O
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 401 - 412
  • [45] The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis
    Cinar, Duygu
    Imirzalioglu, Pervin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : E1 - E10
  • [46] A comparative finite element analysis of two types of axial and radial functionally graded dental implants with titanium one around implant-bone interface
    Shirazi, Hadi Asgharzadeh
    Ayatollahi, Majidreza
    Karimi, Alireza
    Navidbakhsh, Mahdi
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2017, 24 (05) : 747 - 754
  • [47] Evaluating the Feasibility of Short Dental Implants as Alternatives to Long Dental Implants in Mandibular Bone: A Finite Element Study
    Deshmukh, Prathamesh
    Dhatrak, Pankaj
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2024, 112 (09)
  • [48] Biomechanical and finite element analysis for comparison of two PLIF-techniques
    Pitzen, T
    Matthis, D
    Müller-Storz, H
    Caspar, W
    Steudel, WI
    Harms, J
    ZENTRALBLATT FUR NEUROCHIRURGIE, 1999, 60 (03): : 114 - 120
  • [49] Biomechanical investigation of two long bone growth modulation techniques by finite element simulations
    Schneider, Manuel
    Buschbaum, Jan
    Joeris, Alexander
    Roehrle, Oliver
    Dwyer, Jonathan
    Hunter, James B.
    Reynolds, Richard A. K.
    Slongo, Theodor F.
    Gueorguiev, Boyko
    Varga, Peter
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (05) : 1398 - 1405
  • [50] A Finite Element Analysis to Compare Stress Distribution on Extra-Short Implants with Two Different Internal Connections
    Helena Garcia-Braz, Silvia
    Prados-Privado, Maria
    Silveira Zanatta, Luiz Carlos
    Luis Calvo-Guirado, Jose
    Carlos Prados-Frutos, Juan
    Alexandre Gehrke, Sergio
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (08)