Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications

被引:0
|
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
De Bortoli Jr, Nilton [4 ]
Mello, Bruno Freitas [5 ]
Piattelli, Adriano [6 ,7 ]
Mijiritsky, Eitan [8 ,9 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Politecn Bari Univ, Dept Mech Math & Management, I-70125 Bari, Italy
[2] G dAnnunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, I-66100 Chieti, Italy
[4] Assoc Paulista Cirurgioes Dent APCD, Dept Oral Implantol, BR-02011000 Sao Bernardo Do Campo, Brazil
[5] Univ Vale Itajai, Dept Periodont & Implant Dent, BR-88302901 Itajai, Brazil
[6] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[7] UCAM Univ Catolica San Antonio Murcia, Fac Med, Murcia 30107, Spain
[8] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sch Med, Dept Head & Neck Surg & Maxillofacial Surg, IL-64239 Tel Aviv, Israel
[9] Tel Aviv Univ, Fac Med, Goldschleger Sch Dent Med, IL-39040 Tel Aviv, Israel
关键词
finite element analysis (FEA); dental implants; dental stress analysis; short implants; angled implants; inclined abutments; MACHINED-SURFACE IMPLANTS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; AUGMENTED BONE; DIAMETER; TOOTH; QUALITY; CONNECTIONS; RESORPTION; GEOMETRY;
D O I
10.3390/ma17235680
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.5, and 3 mm, corresponding to Bergkvist's classifications IV, III, and II, respectively. A simplified 3D model of the bone was developed for the analysis. Two short implants were inserted into the model: one with a 30 degrees inclined abutment (IA) and another positioned at a 30 degrees angle featuring a straight abutment (II). A vertical force (120 N) was applied to the upper surface of the abutments. FEA software was employed to assess the stresses on the peri-implant tissues and the implants. The findings indicated that a reduction in cortical bone thickness results in an increase in stress within the cortical bone. For IA, the stresses recorded 32.56, 56.12, and 96.14 MPa for cortical thicknesses of 3, 1.5, and 0.5 mm, respectively. Conversely, II exhibited increased stresses across all bone qualities (52.32, 76.15, and 126.32 MPa for the same cortical thicknesses). It is advisable to avoid II in cases of poor bone quality and thin cortical due to the heightened risk of overload-induced bone resorption; however, it may be preferable to use IA in scenarios involving good bone quality and thicker cortical.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Finite element analysis of biomechanical variation of subchondral bone in osteoarthritis
    Chen, Hainan
    Jiang, Wei
    Dong, Qirong
    Yang, Kan
    KUWAIT MEDICAL JOURNAL, 2020, 52 (02): : 175 - 182
  • [22] Biomechanical analysis of partial mandibular implants with various lattice designs of different material properties: In vitro study and finite element analysis
    Zhang, Hao
    Fuh, Lih Jyh
    Hsu, Jui Ting
    Lim, Zhe Min
    Huang, Heng Li
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2024, 10 (06) : 567 - 581
  • [23] Finite element analysis of bone loss around failing implants
    Wolff, Jan
    Narra, Nathaniel
    Antalainen, Anna-Kaisa
    Valasek, Jiri
    Kaiser, Jozef
    Sandor, George K.
    Marcian, Petr
    MATERIALS & DESIGN, 2014, 61 : 177 - 184
  • [24] Biomechanical influence of thread form on stress distribution over short implants (≤6 mm) using finite element analysis
    Liu, Fan
    Mao, Zhi-Hong
    Peng, Wujie
    Wen, Sheng
    Biomedizinische Technik, 2022, 67 (01): : 53 - 60
  • [25] Bone quality effect on short implants in the edentulous mandible: a finite element study
    Chaowei Liu
    Yifeng Xing
    Yan Li
    Yanjun Lin
    Jianghan Xu
    Dong Wu
    BMC Oral Health, 22
  • [26] Bone quality effect on short implants in the edentulous mandible: a finite element study
    Liu, Chaowei
    Xing, Yifeng
    Li, Yan
    Lin, Yanjun
    Xu, Jianghan
    Wu, Dong
    BMC ORAL HEALTH, 2022, 22 (01)
  • [27] Biomechanical influence of thread form on stress distribution over short implants (≤6 mm) using finite element analysis
    Liu, Fan
    Mao, Zhi-Hong
    Peng, Wujie
    Wen, Sheng
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2022, 67 (01): : 53 - 60
  • [28] The evaluation of stress on bone level and tissue level short implants: A Finite Element Analysis (FEA) study
    Avag, Canseda
    Akkocaoglu, Murat
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [29] Letter to the editor about the article "Stress distribution with extra-short implants in an angled frictional system: A finite element analysis study"
    Cecato, Rafael Cury
    Wiggers, William de Souza
    Miura, Alex
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 375 - 379
  • [30] Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants
    Park, Soyeon
    Park, Jieun
    Kang, Inyeong
    Lee, Hyeonjong
    Noh, Gunwoo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 221