Biomechanical analysis of partial mandibular implants with various lattice designs of different material properties: In vitro study and finite element analysis

被引:0
|
作者
Zhang, Hao [1 ]
Fuh, Lih Jyh [1 ,2 ]
Hsu, Jui Ting [3 ]
Lim, Zhe Min [1 ]
Huang, Heng Li [1 ,4 ]
机构
[1] China Med Univ, Sch Dent, Taichung, Taiwan
[2] China Med Univ Hosp, Dept Dent, Taichung, Taiwan
[3] China Med Univ, Dept Biomed Engn, Taichung, Taiwan
[4] Asia Univ, Dept Bioinformat & Med Engn, Taichung, Taiwan
关键词
Mandibular segmental resection; Porous lattice design; Lattice size; Rod diameter; Mandibular implant; Abutment; In vitro experiment; Finite element analysis; PORE-SIZE; RECONSTRUCTION; BONE; PROSTHESIS; STRESS;
D O I
10.36922/ijb.3943
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For patients with mandibular bone defects, although reconstruction plates can be used for repair, achieving both occlusal function and facial aesthetics is challenging. In the present study, in vitro experiments and finite element analysis (FEA) were conducted to determine the biomechanical characteristics of multiple porous lattice structures of varying shapes and diameters that were used for mandibular implants. Additionally, an abutment designed to carry occlusal forces was added to the top of the implants. The stress distribution of four lattice designs (tetrahedron, quad-diametral-cross, hex-star, and hex-vase) of three sizes (2.5, 3.0, and 3.5 mm) in cubic porous models were analyzed by FEA. Subsequently, two optimal designs for 3D-printed titanium alloy were selected. These designs, featuring different lattice diameters (0.5, 0.7, and 0.9 mm), were tested to determine their elastic modulus, which was used in another FEA of a mandibular implant designed for a patient with a malignant tumor in the right mandible. This model, which included an abutment design, was subjected to a vertical force of 100 N and muscle forces generated by biting. This analysis was conducted to determine the elastic modulus of the implant and the values of stress and strain on the implant and surrounding bone. The lattice designs of quad-diametral-cross and hex-vase exhibited smaller high-stress regions than those of tetrahedron and hex-star. In vitro tests revealed that the elastic modulus of the lattices increased with the rod diameter. When these values were applied to mandibular implants, Young's modulus decreased, which in turn increased the frictional stress observed at the interface between the abutment and the implant. However, the implant's maximum stress remained below its yield strength (910 MPa), and the strain on the surrounding bone varied between 1500 and 3000 mu strain. As indicated by Frost's theory, these implants are unlikely to damage the surrounding bone tissue and are likely to support bone growth.
引用
收藏
页码:567 / 581
页数:15
相关论文
共 50 条
  • [1] Biomechanical performance of cranial implants with different thicknesses and material properties: A finite element study
    Marcian, Petr
    Narra, Nathaniel
    Borak, Libor
    Chamrad, Jakub
    Wolff, Jan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 109 : 43 - 52
  • [2] Three-dimensional finite element analysis of the biomechanical properties of different material implants for replacing missing teeth
    Gao, Yichen
    He, Xianyi
    Xu, Wei
    Deng, Yuyao
    Xia, Zhaoxin
    Chen, Junliang
    He, Yun
    ODONTOLOGY, 2025, 113 (01) : 80 - 88
  • [3] Biomechanical and Finite Element Analysis of Mandibular Vertical Ramus Marginal Resection Designs
    Shyam Sundar S.
    Nandlal B.
    Saikrishna D.
    Mallesh G.
    Journal of Maxillofacial and Oral Surgery, 2013, 12 (3) : 297 - 306
  • [4] Biomechanical comparison of different framework materials in mandibular overdenture prosthesis supported with implants of different sizes: a finite element analysis
    Guzelce, S. Elifnur
    BMC ORAL HEALTH, 2023, 23 (01)
  • [5] Biomechanical comparison of different framework materials in mandibular overdenture prosthesis supported with implants of different sizes: a finite element analysis
    Elifnur Güzelce S
    BMC Oral Health, 23
  • [6] Biomechanical analysis of different fixed dental restorations on short implants: a finite element study
    Wagner, Christian
    Herberg, Samira
    Bourauel, Christoph
    Stark, Helmut
    Doersam, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (03): : 241 - 250
  • [7] A biomechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model
    Miyuki Omori
    Yuji Sato
    Noboru Kitagawa
    Yuta Shimura
    Manabu Ito
    International Journal of Implant Dentistry, 1 (1)
  • [8] A biomechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model
    Omori, Miyuki
    Sato, Yuji
    Kitagawa, Noboru
    Shimura, Yuta
    Ito, Manabu
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2015, 1 (01):
  • [9] BIOMECHANICAL EVALUATION OF MANDIBULAR OVERDENTURES SUPPORTED BY MINI-IMPLANTS: A FINITE ELEMENT ANALYSIS
    Ganesh, Thiagarajan
    Scully, Jessica
    Walker, Mary P.
    Petrie, Cynthia S.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (06)
  • [10] Finite element analysis of primary healing implants with different transmucosal designs
    Ceddia, Mario
    Romasco, Tea
    Comuzzi, Luca
    Cipollina, Alessandro
    Piattelli, Adriano
    Di Pietro, Natalia
    Trentadue, Bartolomeo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,