Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications

被引:0
|
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
De Bortoli Jr, Nilton [4 ]
Mello, Bruno Freitas [5 ]
Piattelli, Adriano [6 ,7 ]
Mijiritsky, Eitan [8 ,9 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Politecn Bari Univ, Dept Mech Math & Management, I-70125 Bari, Italy
[2] G dAnnunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, I-66100 Chieti, Italy
[4] Assoc Paulista Cirurgioes Dent APCD, Dept Oral Implantol, BR-02011000 Sao Bernardo Do Campo, Brazil
[5] Univ Vale Itajai, Dept Periodont & Implant Dent, BR-88302901 Itajai, Brazil
[6] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[7] UCAM Univ Catolica San Antonio Murcia, Fac Med, Murcia 30107, Spain
[8] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sch Med, Dept Head & Neck Surg & Maxillofacial Surg, IL-64239 Tel Aviv, Israel
[9] Tel Aviv Univ, Fac Med, Goldschleger Sch Dent Med, IL-39040 Tel Aviv, Israel
关键词
finite element analysis (FEA); dental implants; dental stress analysis; short implants; angled implants; inclined abutments; MACHINED-SURFACE IMPLANTS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; AUGMENTED BONE; DIAMETER; TOOTH; QUALITY; CONNECTIONS; RESORPTION; GEOMETRY;
D O I
10.3390/ma17235680
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.5, and 3 mm, corresponding to Bergkvist's classifications IV, III, and II, respectively. A simplified 3D model of the bone was developed for the analysis. Two short implants were inserted into the model: one with a 30 degrees inclined abutment (IA) and another positioned at a 30 degrees angle featuring a straight abutment (II). A vertical force (120 N) was applied to the upper surface of the abutments. FEA software was employed to assess the stresses on the peri-implant tissues and the implants. The findings indicated that a reduction in cortical bone thickness results in an increase in stress within the cortical bone. For IA, the stresses recorded 32.56, 56.12, and 96.14 MPa for cortical thicknesses of 3, 1.5, and 0.5 mm, respectively. Conversely, II exhibited increased stresses across all bone qualities (52.32, 76.15, and 126.32 MPa for the same cortical thicknesses). It is advisable to avoid II in cases of poor bone quality and thin cortical due to the heightened risk of overload-induced bone resorption; however, it may be preferable to use IA in scenarios involving good bone quality and thicker cortical.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Biomechanical Analysis of Functionally Graded Root Analog Implants on Alveolar Bone: A 3D Finite Element Study
    Wang, Feilong
    Jiang, Zhaoliang
    Si, Pengchao
    Lan, Jing
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : E63 - E71
  • [32] Nonlinear Finite Element Analysis of Shearwalls with Various Types of Openings
    Baek, Ii Bae
    Hyun, Ki Choi
    Choi, Chang Sik
    ADVANCED ENGINEERING MATERIALS, PTS 1-3, 2011, 194-196 : 1900 - 1903
  • [33] Finite Element Analysis and Biomechanical Testing of the New MiniMIS Short Stem
    Trieb, Klemens
    Huber, Dominik
    Sonntag, Robert
    Kretzer, Jan Philippe
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2019, 157 (02): : 188 - 193
  • [34] Biomechanical finite element analysis of small diameter and short dental implant
    Hasan, Istabrak
    Heinemann, Friedhelm
    Aitlahrach, Maria
    Bourauel, Christoph
    BIOMEDIZINISCHE TECHNIK, 2010, 55 (06): : 341 - 350
  • [35] Optimal biomechanical choice of implant placement in various pilon fracture types: a finite element study
    Liu, Peizhao
    Mei, Xianzhong
    Wang, Zhixiang
    Xu, Feng
    Cai, Xianhua
    Shou, Kangquan
    Wei, Shijun
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [36] Biomechanical investigations and finite element analysis of a bone-implant interface
    Widjaja, W
    Hartung, C
    BIOMEDIZINISCHE TECHNIK, 2001, 46 (12): : 351 - 354
  • [37] Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study
    Gumrukcu, Zeynep
    Korkmaz, Yavuz Tolga
    Korkmaz, Fatih Mehmet
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 86 : 47 - 54
  • [38] Biomechanical optimisation of the length ratio of the two endosseous portions in distraction implants: a three-dimensional finite element analysis
    Gao, Yuan
    Li, Yong-Feng
    Shao, Bo
    Li, Tao
    Xia, Ning
    Xu, Li-Xian
    Wang, Zhong-Yi
    Kong, Liang
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2012, 50 (06): : E86 - E92
  • [39] A biomechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model
    Miyuki Omori
    Yuji Sato
    Noboru Kitagawa
    Yuta Shimura
    Manabu Ito
    International Journal of Implant Dentistry, 1 (1)
  • [40] Evaluating Angled Abutments: Three-Dimensional Finite Element Stress Analysis of Anterior Maxillary Implants
    Chethan, K. N.
    Eram, Afiya
    Shetty, Nisha
    Shetty, Divya D.
    Futane, Mohan
    Keni, Laxmikant G.
    PROSTHESIS, 2024, 6 (02): : 315 - 328