Optimal biomechanical choice of implant placement in various pilon fracture types: a finite element study

被引:0
|
作者
Liu, Peizhao [1 ]
Mei, Xianzhong [2 ]
Wang, Zhixiang [3 ]
Xu, Feng [1 ]
Cai, Xianhua [4 ]
Shou, Kangquan [5 ,6 ]
Wei, Shijun [1 ,7 ]
机构
[1] Gen Hosp Cent Theater Command PLA, Dept Orthopaed, Wuhan Gen Hosp Guangzhou Command, 627 Wuluo Rd, Wuhan 430030, Hubei, Peoples R China
[2] Shenzhen Pingle Orthoped Hosp, Dept Orthoped, Shenzhen, Guangdong, Peoples R China
[3] Wuhan 1 Hosp, Dept Orthoped, Wuhan, Hubei, Peoples R China
[4] Shenzhen Univ, South China Hosp, Med Sch, Dept Orthoped, Shenzhen 518116, Guangdong, Peoples R China
[5] China Three Gorges Univ, Coll Clin Med Sch 1, Dept Orthoped, Yichang, Hubei, Peoples R China
[6] Yichang Cent Peoples Hosp, Yichang, Hubei, Peoples R China
[7] Southern Med Univ, Sch Clin Med 1, Guangzhou, Guangdong, Peoples R China
关键词
Pilon fracture; Distal tibial fracture; Fracture displacement; Implants; Buttress plate; Finite element analysis; POSTERIOR PILON; FIXATION; BONE; PLATE;
D O I
10.1186/s12891-024-08076-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe research on the biomechanical characteristics of individual implant placement for pilon fractures based on the different initial direction of fracture displacement is still insufficient. This study's aim is to compare the stress distribution in bones and implants with various pilon fracture types.MethodsVarus, valgus, dorsiflexion, and plantarflexion type fractures were categorized as type I, II, III, and IV, respectively. The buttress plate was placed medially in subtypes IA and IIB, whereas it was placed anterolaterally in subtypes IB and IIA; The anterior or posterior buttress plate was utilized in subtypes IIIA and IVA, the lag screws were applied in subtypes IIIB and IVB. The maximum equivalent stress of tibia (TI-Smax) and implants (IF-Smax), stress of fracture fragments (Sfe), and axial displacement values of the fracture fragments (ADfe) in each subtype were analyzed when the ankle was in a neutral position, 15 degrees of varus and valgus in types I and II, 15 degrees of dorsiflexion and plantarflexion in types III and IV.ResultsUnder the same axial stress loading conditions, TI-Smax, Sfe, ADfe of subtypes IA and IIA were significantly lower than subtypes IB and IIB, while IF-Smax of subtypes IA and IIA were obviously larger than subtypes IB and IIB. Additionally, TI-Smax, Sfe, ADfe of subtypes IIIA and IVA were considerably lower as IF-Smax met expectations compared to subtypes IIIB and IVB.ConclusionBased on these results, when making decisions for open reduction and internal fixation in various pilon fractures, the choice and placement of the implant can be recommended as follows: the medial buttress plate for varus types; the anterolateral plate for valgus types; the anterior plate for dorsiflexion types; the posterior plate for plantarflexion types.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study
    Gumrukcu, Zeynep
    Korkmaz, Yavuz Tolga
    Korkmaz, Fatih Mehmet
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 86 : 47 - 54
  • [2] Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study
    Muhammad Hanif Ramlee
    Mohd Ayub Sulong
    Evelyn Garcia-Nieto
    Daniel Angure Penaranda
    Antonio Ros Felip
    Mohammed Rafiq Abdul Kadir
    Medical & Biological Engineering & Computing, 2018, 56 : 1925 - 1938
  • [3] Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study
    Ramlee, Muhammad Hanif
    Sulong, Mohd Ayub
    Garcia-Nieto, Evelyn
    Penaranda, Daniel Angure
    Felip, Antonio Ros
    Kadir, Mohammed Rafiq Abdul
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (10) : 1925 - 1938
  • [4] Biomechanical Effects of Various Bone-Implant Interfaces on the Stability of Orthodontic Miniscrews: A Finite Element Study
    Tan, Fabing
    Wang, Chao
    Yang, Chongshi
    Huang, Yuanding
    Fan, Yubo
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [5] Study of a constrained finite element elbow prosthesis: the influence of the implant placement
    Nalbone, Lorenzo
    Monac, Francesco
    Nalbone, Luca
    Ingrassia, Tommaso
    Ricotta, Vito
    Nigrelli, Vincenzo
    Ferruzza, Massimo
    Tarallo, Luigi
    Porcellini, Giuseppe
    Camarda, Lawrence
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)
  • [6] Study of a constrained finite element elbow prosthesis: the influence of the implant placement
    Lorenzo Nalbone
    Francesco Monac
    Luca Nalbone
    Tommaso Ingrassia
    Vito Ricotta
    Vincenzo Nigrelli
    Massimo Ferruzza
    Luigi Tarallo
    Giuseppe Porcellini
    Lawrence Camarda
    Journal of Orthopaedics and Traumatology, 24
  • [7] Biomechanical Evaluation of a Novel Porous-Structure Implant: Finite Element Study
    Inglam, Samroeng
    Chantarapanich, Nattapon
    Suebnukarn, Siriwan
    Vatanapatimaku, Natapoom
    Sucharitpwatskul, Sedthawatt
    Sitthiseripratip, Kriskrai
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : E48 - E56
  • [8] Biomechanical Evaluation of Zygomatic Implant Versus Pterygoid Implant in Atrophic Maxilla: An In vitro Finite Element Study
    Daniel, Diana
    Pande, Deepa
    Bakshi, Javeed Hussain I.
    Jose, Jerin
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024, 23 (03): : 734 - 744
  • [9] Biomechanical effect of crestal bone osteoplasty before implant placement: a three-dimensional finite element analysis
    Hudieb, M.
    Kasugai, S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (02) : 200 - 206
  • [10] Biomechanical Analysis of the External Fixation in a Lumbar Fracture Model: A Finite Element Study
    Yijia Liao
    Yiguo Yan
    Yu Kang
    Wenjun Wang
    Xizheng Song
    Wen Peng
    Haibin Fu
    Huarong Chen
    Cheng Wang
    Journal of Medical and Biological Engineering, 2022, 42 : 469 - 478