Experimental and exergy analysis of air-conditioning condensate energy recovery in HVAC and cold storage units

被引:0
|
作者
Dhamodharan, Palanisamy [1 ,2 ]
Bakthavatsalam, A. K. [3 ]
Prabakaran, Rajendran [4 ]
Choi, Gyu Sang [1 ]
Kim, Sung Chul [4 ]
机构
[1] Yeungnam Univ, Dept Informat & Commun Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] Saveetha Inst Med & Tech Sci SIMATS, Saveetha Sch Engn, Chennai 602105, India
[3] Natl Inst Technol, Dept Energy & Environm, Tiruchirappalli 620015, Tamil Nadu, India
[4] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyeongbuk 712749, Gyeongsan, South Korea
基金
新加坡国家研究基金会;
关键词
Condensate energy recovery; Exergy analysis; Air-water heat exchanger and thermal energy; storage; Economic analysis; Environmental sustainability; THERMOECONOMIC ANALYSIS; THERMAL STORAGE; HEAT; PERFORMANCE; SYSTEMS; WATER; WASTE;
D O I
10.1016/j.tsep.2025.103255
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning (AC) condensate, a valuable source of chilled energy, holds significant potential for energy recovery. Preliminary assessments showed daily condensate collection rates of 0.8-1.1 L/h for split AC (1.5 TR), 34 L/h for packaged AC (88 TR), and 180-195 L for cold storage plants (5000 TR). This study investigates the use of an Air-Water Heat Exchanger (AWHX) and Thermal Energy Storage (TES) system for condensate energy recovery across different air-conditioning capacities. Theoretical analysis (energy and exergy) and pilot experiments were conducted to design an effective condensate energy recovery system. Exergy analysis performed in the AWHX system, reveals the efficiency was improved with increase in temperature from 15 to 20 degrees C. Likewise, TES-assisted recovery exhibited a decrease in exergy efficiency at high ambient temperatures. Experiments were carried out in packaged AC and cold storage units integrated with a condensate energy recovery system. Additionally, the usefulness of the packaged AC with AWHX and TES was assessed by measuring indoor air quality (IAQ). Condensate with 17 degrees C and 7.5 L/h effectively pre-cooled the air by 3-3.2 degrees C which significantly improved the IAQ. Similarly, experiments conducted in cold storage units with a TES-based condensate recovery system resulted in 3-4 degrees C reduction in product temperature. Economic analysis indicated annual energy cost savings of $40, $99, and $32 for systems of split AC, packaged AC, and cold storage, respectively. The packaged AC system exhibited a 57 % greater reduction in environmental impact compared to the cold storage plant, highlighting its environmental sustainability benefits.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Enhancing cold storage efficiency: Sustainable apple pre-cooling utilizing polyethylene glycol and waste coconut oil as phase change materials for chilled energy recovery from air-conditioning condensate
    Dhamodharan, Palanisamy
    Bakthavatsalam, A. K.
    Nijin, V. P.
    Prabakaran, Rajendran
    Kim, Sung Chul
    ENERGY, 2024, 297
  • [42] Optimal Energy Reduction Schedules for Ice Storage Air-Conditioning Systems
    Lin, Whei-Min
    Tu, Chia-Sheng
    Tsai, Ming-Tang
    Lo, Chi-Chun
    ENERGIES, 2015, 8 (09): : 10504 - 10521
  • [43] Performance enhancement of cold energy storage using phase change materials with fumed silica for air-conditioning applications
    Nie, Binjian
    Du, Zheng
    Chen, Jie
    Zou, Boyang
    Ding, Yulong
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (11) : 16565 - 16575
  • [44] Experimental evaluation of desiccant dehumidification and air-conditioning system for energy-efficient storage of dried fruits
    Mahmood, Muhammad H.
    Sultan, Muhammad
    Miyazaki, Takahiko
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2020, 41 (04): : 454 - 465
  • [45] Energy efficiency of cold or heat sources in air-conditioning systems & building energy conservation
    Wang, CQ
    Long, WD
    Ding, WT
    Wu, QQ
    Zhong, T
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 953 - 959
  • [46] Regulation and Stabilization by Ice Storage Air-Conditioning and Battery Energy Storage System in microgrids
    Yang, Lian
    Tai, Nengling
    Fan, Chunju
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 12 (02) : 176 - 184
  • [47] The techno-economic and environmental analysis of genetic algorithm (GA) optimized cold thermal energy storage (CTES) for air-conditioning applications
    Barthwal, Mohit
    Dhar, Atul
    Powar, Satvasheel
    APPLIED ENERGY, 2021, 283
  • [48] Exergy Analysis of Energy Consumption for Central Air Conditioning System
    Xia, Xiaoxia
    Zhou, Naijun
    Wang, Zhiqi
    MATERIALS SCIENCE, MECHANICAL ENGINEERING AND APPLIED RESEARCH, 2014, 628 : 332 - 337
  • [49] Analysis of Microbiology Test of Air-Conditioning System in Severe Cold Area
    Li, Huixing
    Li, Beini
    Feng, Guohui
    Cheng, Peng
    Tang, Chengcheng
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 457 - 465
  • [50] Cumulative exergy analysis of ice thermal storage air conditioning system
    Pu, Jing
    Liu, Guilian
    Feng, Xiao
    APPLIED ENERGY, 2012, 93 : 564 - 569