Experimental and exergy analysis of air-conditioning condensate energy recovery in HVAC and cold storage units

被引:0
|
作者
Dhamodharan, Palanisamy [1 ,2 ]
Bakthavatsalam, A. K. [3 ]
Prabakaran, Rajendran [4 ]
Choi, Gyu Sang [1 ]
Kim, Sung Chul [4 ]
机构
[1] Yeungnam Univ, Dept Informat & Commun Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] Saveetha Inst Med & Tech Sci SIMATS, Saveetha Sch Engn, Chennai 602105, India
[3] Natl Inst Technol, Dept Energy & Environm, Tiruchirappalli 620015, Tamil Nadu, India
[4] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyeongbuk 712749, Gyeongsan, South Korea
基金
新加坡国家研究基金会;
关键词
Condensate energy recovery; Exergy analysis; Air-water heat exchanger and thermal energy; storage; Economic analysis; Environmental sustainability; THERMOECONOMIC ANALYSIS; THERMAL STORAGE; HEAT; PERFORMANCE; SYSTEMS; WATER; WASTE;
D O I
10.1016/j.tsep.2025.103255
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning (AC) condensate, a valuable source of chilled energy, holds significant potential for energy recovery. Preliminary assessments showed daily condensate collection rates of 0.8-1.1 L/h for split AC (1.5 TR), 34 L/h for packaged AC (88 TR), and 180-195 L for cold storage plants (5000 TR). This study investigates the use of an Air-Water Heat Exchanger (AWHX) and Thermal Energy Storage (TES) system for condensate energy recovery across different air-conditioning capacities. Theoretical analysis (energy and exergy) and pilot experiments were conducted to design an effective condensate energy recovery system. Exergy analysis performed in the AWHX system, reveals the efficiency was improved with increase in temperature from 15 to 20 degrees C. Likewise, TES-assisted recovery exhibited a decrease in exergy efficiency at high ambient temperatures. Experiments were carried out in packaged AC and cold storage units integrated with a condensate energy recovery system. Additionally, the usefulness of the packaged AC with AWHX and TES was assessed by measuring indoor air quality (IAQ). Condensate with 17 degrees C and 7.5 L/h effectively pre-cooled the air by 3-3.2 degrees C which significantly improved the IAQ. Similarly, experiments conducted in cold storage units with a TES-based condensate recovery system resulted in 3-4 degrees C reduction in product temperature. Economic analysis indicated annual energy cost savings of $40, $99, and $32 for systems of split AC, packaged AC, and cold storage, respectively. The packaged AC system exhibited a 57 % greater reduction in environmental impact compared to the cold storage plant, highlighting its environmental sustainability benefits.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] ENERGY-SAVING OPTIMIZATION CONTROL METHOD OF COMMERCIAL BUILDING DOUBLE COLD SOURCE AIR-CONDITIONING UNITS
    Wang, Yan
    Zhang, Xiaohui
    Meng, Yanhua
    Wang, Xianyi
    THERMAL SCIENCE, 2022, 26 (4B): : 3545 - 3558
  • [32] Energy saving through evaporatively cooled condenser air in conventional air-conditioning units
    Mathur, A.C., 1600, Publ by Ambient Press Ltd, Lutterworth, United Kingdom (15):
  • [33] Exergy analysis of a liquid-desiccant-based, hybrid air-conditioning system
    Ahmed, CSK
    Gandhidasan, P
    Zubair, SM
    Al-Farayedhi, AA
    ENERGY, 1998, 23 (01) : 51 - 59
  • [34] Exergy and Thermoeconomic Analysis for an Underground Train Station Air-Conditioning Cooling System
    Liao, Ke Yang
    Chuah, Yew Khoy
    ENTROPY, 2016, 18 (03)
  • [35] A review on phase change cold storage in air-conditioning system: Materials and applications
    Zhai, X. Q.
    Wang, X. L.
    Wang, T.
    Wang, R. Z.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 22 : 108 - 120
  • [36] Cold Storage Capacity for Solar Air-Conditioning in Office Buildings in Different Climates
    Sun Zhifeng
    Zhao Yaohua
    Xu Wei
    Wang Dongxu
    Li Huiyong
    Zhang Xinyu
    Li Huai
    Li Yang
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (06) : 1195 - 1204
  • [37] Cold Storage Capacity for Solar Air-Conditioning in Office Buildings in Different Climates
    Zhifeng Sun
    Yaohua Zhao
    Wei Xu
    Dongxu Wang
    Huiyong Li
    Xinyu Zhang
    Huai Li
    Yang Li
    Journal of Thermal Science, 2019, 28 : 1195 - 1204
  • [38] Cold Storage Capacity for Solar Air-Conditioning in Office Buildings in Different Climates
    SUN Zhifeng
    ZHAO Yaohua
    XU Wei
    WANG Dongxu
    LI Huiyong
    ZHANG Xinyu
    LI Huai
    LI Yang
    Journal of Thermal Science, 2019, 28 (06) : 1195 - 1204
  • [39] Optimized control mode of a central air-conditioning cold storage system operation
    Yu, Guangbao
    Liu, Zhenyan
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, (04): : 282 - 284
  • [40] Simulation and Dynamic Analysis of Cool Storage Tank for Air-conditioning
    Li, Xiao-Yan
    Zhou, Ya-Chen
    Qiu, Mei-Ling
    ICIC 2009: SECOND INTERNATIONAL CONFERENCE ON INFORMATION AND COMPUTING SCIENCE, VOL 4, PROCEEDINGS: MODELLING AND SIMULATION IN ENGINEERING, 2009, : 374 - 377