Experimental and exergy analysis of air-conditioning condensate energy recovery in HVAC and cold storage units

被引:0
|
作者
Dhamodharan, Palanisamy [1 ,2 ]
Bakthavatsalam, A. K. [3 ]
Prabakaran, Rajendran [4 ]
Choi, Gyu Sang [1 ]
Kim, Sung Chul [4 ]
机构
[1] Yeungnam Univ, Dept Informat & Commun Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] Saveetha Inst Med & Tech Sci SIMATS, Saveetha Sch Engn, Chennai 602105, India
[3] Natl Inst Technol, Dept Energy & Environm, Tiruchirappalli 620015, Tamil Nadu, India
[4] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyeongbuk 712749, Gyeongsan, South Korea
基金
新加坡国家研究基金会;
关键词
Condensate energy recovery; Exergy analysis; Air-water heat exchanger and thermal energy; storage; Economic analysis; Environmental sustainability; THERMOECONOMIC ANALYSIS; THERMAL STORAGE; HEAT; PERFORMANCE; SYSTEMS; WATER; WASTE;
D O I
10.1016/j.tsep.2025.103255
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning (AC) condensate, a valuable source of chilled energy, holds significant potential for energy recovery. Preliminary assessments showed daily condensate collection rates of 0.8-1.1 L/h for split AC (1.5 TR), 34 L/h for packaged AC (88 TR), and 180-195 L for cold storage plants (5000 TR). This study investigates the use of an Air-Water Heat Exchanger (AWHX) and Thermal Energy Storage (TES) system for condensate energy recovery across different air-conditioning capacities. Theoretical analysis (energy and exergy) and pilot experiments were conducted to design an effective condensate energy recovery system. Exergy analysis performed in the AWHX system, reveals the efficiency was improved with increase in temperature from 15 to 20 degrees C. Likewise, TES-assisted recovery exhibited a decrease in exergy efficiency at high ambient temperatures. Experiments were carried out in packaged AC and cold storage units integrated with a condensate energy recovery system. Additionally, the usefulness of the packaged AC with AWHX and TES was assessed by measuring indoor air quality (IAQ). Condensate with 17 degrees C and 7.5 L/h effectively pre-cooled the air by 3-3.2 degrees C which significantly improved the IAQ. Similarly, experiments conducted in cold storage units with a TES-based condensate recovery system resulted in 3-4 degrees C reduction in product temperature. Economic analysis indicated annual energy cost savings of $40, $99, and $32 for systems of split AC, packaged AC, and cold storage, respectively. The packaged AC system exhibited a 57 % greater reduction in environmental impact compared to the cold storage plant, highlighting its environmental sustainability benefits.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Exergy analysis of moist air and energy saving potential in HVAC by evaporative cooling or energy recovery
    Ren, CQ
    Tang, GF
    Li, NP
    Zhang, GF
    Yang, J
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 120 - 124
  • [12] Testing for Energy Recovery Ventilators and Energy Saving Analysis with Air-Conditioning Systems
    Yang, Peng
    Li, Li
    Wang, Jianqin
    Huang, Guilin
    Peng, Jingli
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 438 - 445
  • [13] Exergy analysis of ice storage air-conditioning system with heat pipe during charging period
    Fang, Guiyin
    Liu, Xu
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2010, 14 (02) : 149 - 153
  • [14] Exergy analysis of refrigerating units of textile air conditioning
    Li, Xinyu
    Chen, Jie
    Liu, Shusen
    Jin, Xing
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 155 - 160
  • [15] Numerical Analysis of Exergy for Air-Conditioning Influenced by Ambient Temperature
    Lee, Jing-Nang
    Chen, Chien-Chih
    Ting, Chen-Ching
    INTERNATIONAL JOURNAL OF ENGINEERING AND TECHNOLOGY INNOVATION, 2014, 4 (03) : 152 - 160
  • [16] The economic evaluation methods of air-conditioning cold storage system
    Yonggui, Zhang
    Sukun, Pang
    Guiquan, Liu
    Electronic Journal of Geotechnical Engineering, 2014, 19 (0H): : 1791 - 1800
  • [17] Chilled energy storage for air-conditioning system of buildings
    Shu, Xiaojian
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE IV, PTS 1-5, 2014, 496-500 : 1020 - 1023
  • [18] Air-conditioning condensate recovery and applications-Current developments and challenges ahead
    Algarni, Salem
    Saleel, C. A.
    Mujeebu, M. Abdul
    SUSTAINABLE CITIES AND SOCIETY, 2018, 37 : 263 - 274
  • [19] Advanced exergy analysis of an air conditioning system incorporating thermal energy storage
    Mosaffa, A. H.
    Farshi, L. Garousi
    Ferreira, C. A. Infante
    Rosen, M. A.
    ENERGY, 2014, 77 : 945 - 952
  • [20] Simulation and Energy Economic Analysis of an Air-Conditioning System with Energy Recovery Ventilator in Summer
    Li, Li
    Li, Yaping
    Zhang, Qingling
    Tao, Qiuhua
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 47 - 54