Experimental and exergy analysis of air-conditioning condensate energy recovery in HVAC and cold storage units

被引:0
|
作者
Dhamodharan, Palanisamy [1 ,2 ]
Bakthavatsalam, A. K. [3 ]
Prabakaran, Rajendran [4 ]
Choi, Gyu Sang [1 ]
Kim, Sung Chul [4 ]
机构
[1] Yeungnam Univ, Dept Informat & Commun Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] Saveetha Inst Med & Tech Sci SIMATS, Saveetha Sch Engn, Chennai 602105, India
[3] Natl Inst Technol, Dept Energy & Environm, Tiruchirappalli 620015, Tamil Nadu, India
[4] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyeongbuk 712749, Gyeongsan, South Korea
基金
新加坡国家研究基金会;
关键词
Condensate energy recovery; Exergy analysis; Air-water heat exchanger and thermal energy; storage; Economic analysis; Environmental sustainability; THERMOECONOMIC ANALYSIS; THERMAL STORAGE; HEAT; PERFORMANCE; SYSTEMS; WATER; WASTE;
D O I
10.1016/j.tsep.2025.103255
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning (AC) condensate, a valuable source of chilled energy, holds significant potential for energy recovery. Preliminary assessments showed daily condensate collection rates of 0.8-1.1 L/h for split AC (1.5 TR), 34 L/h for packaged AC (88 TR), and 180-195 L for cold storage plants (5000 TR). This study investigates the use of an Air-Water Heat Exchanger (AWHX) and Thermal Energy Storage (TES) system for condensate energy recovery across different air-conditioning capacities. Theoretical analysis (energy and exergy) and pilot experiments were conducted to design an effective condensate energy recovery system. Exergy analysis performed in the AWHX system, reveals the efficiency was improved with increase in temperature from 15 to 20 degrees C. Likewise, TES-assisted recovery exhibited a decrease in exergy efficiency at high ambient temperatures. Experiments were carried out in packaged AC and cold storage units integrated with a condensate energy recovery system. Additionally, the usefulness of the packaged AC with AWHX and TES was assessed by measuring indoor air quality (IAQ). Condensate with 17 degrees C and 7.5 L/h effectively pre-cooled the air by 3-3.2 degrees C which significantly improved the IAQ. Similarly, experiments conducted in cold storage units with a TES-based condensate recovery system resulted in 3-4 degrees C reduction in product temperature. Economic analysis indicated annual energy cost savings of $40, $99, and $32 for systems of split AC, packaged AC, and cold storage, respectively. The packaged AC system exhibited a 57 % greater reduction in environmental impact compared to the cold storage plant, highlighting its environmental sustainability benefits.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Experimental investigation of a novel phase change cold storage used for a solar air-conditioning system
    Zhai, Xiaoqiang
    Wang, Xiaolin
    Wang, Cong
    Wang, Ruzhu
    HVAC&R RESEARCH, 2014, 20 (03): : 302 - 310
  • [22] The analysis on intelligent control strategies of a thermal energy storage air-conditioning system
    Yang, KH
    Su, CH
    Hwang, RL
    ENERGY, 1996, 21 (04) : 319 - 324
  • [23] Experimental study on heat recovery and utilization of air conditioning condensate
    Chen, Xiaoyu
    Liang, Yiting
    Yin, Linjian
    Cheng, Haifeng
    ENERGY REPORTS, 2024, 12 : 4004 - 4015
  • [24] ENERGY-CONSERVATION IN COMMERCIAL AIR-CONDITIONING THROUGH ICE STORAGE AND COLD AIR-DISTRIBUTION DESIGN
    TASSOU, SA
    LEUNG, YK
    HEAT RECOVERY SYSTEMS & CHP, 1992, 12 (05): : 419 - 425
  • [25] Exergy analysis of two humidification process methods in air-conditioning systems
    Ghazikhani, M.
    Khazaee, I.
    Vahidifar, S.
    ENERGY AND BUILDINGS, 2016, 124 : 129 - 140
  • [26] Exergy analysis of an inter-city bus air-conditioning system
    Tosun, E.
    Bilgili, M.
    Tuccar, G.
    Yasar, A.
    Aydin, K.
    INTERNATIONAL JOURNAL OF EXERGY, 2016, 20 (04) : 445 - 464
  • [27] Study on chilled energy storage of air-conditioning system with energy saving
    Lin, Hu
    Li, Xin-hong
    Cheng, Peng-sheng
    Xu, Bu-gong
    ENERGY AND BUILDINGS, 2014, 79 : 41 - 46
  • [28] Energy and exergy performance analysis of a marine rotary desiccant air-conditioning system based on orthogonal experiment
    Zhu, Jun
    Chen, Wu
    ENERGY, 2014, 77 : 953 - 962
  • [29] STUDY OF A GREEN ROOF BUILDING AIR-CONDITIONING SYSTEM WITH THERMAL ENERGY STORAGE UNITS USING LIGHT WEIGHT SOIL - PERFORMANCES OF THERMAL ENERGY STORAGE UNITS
    Otaka, Toshio
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 1, 2009, : 299 - 303
  • [30] Control and monitoring of air-conditioning units through cloud storage and control operations
    Aravind, Chockalingam Vaithilingam
    Majrani, Mohsen
    INTERNATIONAL JOURNAL OF GRID AND UTILITY COMPUTING, 2021, 12 (5-6) : 499 - 506