Experimental study of static and fatigue push-out test on headed stud shear connectors in UHPC composite steel beams

被引:1
|
作者
Gyawali, Mohit [1 ]
Sennah, Khaled [1 ]
Ahmed, Mizan [2 ]
Hamoda, Ahmed [3 ]
机构
[1] Toronto Metropolitan Univ, Civil Engn Dept, 350 Victoria St, Toronto, ON M5B 2K3, Canada
[2] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Bentley, WA 6102, Australia
[3] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
关键词
Ultra high-performance concrete; Composite girders; Shear connectors; Push-out tests; HIGH-STRENGTH; BEHAVIOR;
D O I
10.1016/j.istruc.2024.107923
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite girder bridges utilize shear connectors to connect concrete deck slabs and steel girders. In current practice, the headed shear stud connector is the most used due to its reliability and ease of installation. Several studies are available on the static and fatigue behavior of welded-headed shear studs embedded in normal-strength concrete. However, relatively little is known about the static and fatigue behavior of headed shear connectors in composite beams when shear studs are embedded in ultra-high-performance concrete (UHPC). This study reports a series of pushout results carried out on headed shear connectors embedded in UHPC at pre-fatigue and post-fatigue stages. Six pushout specimens were first tested under static load to collapse. The precast normal-strength concrete slabs in the pushout specimens were reinforced with glass fiber-reinforced polymer (GFRP) bars to promote sustainable construction. This practice, commonly used in Canada, aims to eliminate the corrosion of steel bars caused by de-icing salts used during winter. The results from these tests were used to determine the applied fatigue stress range of another six identical pushout specimens, which were subjected to constant amplitude fatigue loading over 2 million cycles. Results show that the fatigue cycles applied to the specimens prior to testing them to collapse did not alter the failure mode or the crack pattern of the tested specimens. Furthermore, the studied pushout specimens considered 6 different shapes of shear pockets in which the arrangement and spacing of studs were varied. It was found that the studs in a square pocket form yielded a shear capacity of 13.9 % and 16.7 % greater than those for similar studs arranged in a single row-oriented longitudinally and transversally, respectively. The accuracy of the various design formulas specified in design codes in estimating the shear resistance of the tested specimens, as well as empirical formulas proposed to develop load-slip curves of tested specimens, is studied. It was found that the European and Japanese codes significantly underestimated the stud shear capacity, whereas the Canadian code provides a more accurate estimation.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Study on the Flexural Behavior of Steel-Concrete Composite Beams Based on the Shear Performance of Headed Stud Connectors
    Zhang, Song
    Jia, Yanmin
    Ding, Yixing
    BUILDINGS, 2022, 12 (07)
  • [42] Static behavior of stud shear connectors in elastic concrete-steel composite beams
    Han, Qinghua
    Wang, Yihong
    Xu, Jie
    Xing, Ying
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 113 : 115 - 126
  • [43] Push-out tests on demountable shear connectors of steel-concrete composite structures
    Kozma, A.
    Odenbreit, C.
    Braun, M., V
    Veljkovic, M.
    Nijgh, M. P.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 549 - 556
  • [44] Push-out tests on demountable shear connectors of steel-concrete composite structures
    Kozma, A.
    Odenbreit, C.
    Braun, M., V
    Veljkovic, M.
    Nijgh, M. P.
    STRUCTURES, 2019, 21 : 45 - 54
  • [45] Push-out Test and Numerical Analysis of Embedded Shear Connectors with Corrugated Steel Plates
    Song R.-N.
    Zhan Y.-L.
    Zhao R.-D.
    Mou T.-M.
    Fan B.-K.
    Shao J.-H.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2019, 32 (05): : 88 - 99
  • [46] Push-out test and analysis of steel pile caps strengthened with perfobond shear connectors
    Rhim, Hong Chul
    Kang, Jae-Yoon
    Kim, Young Ho
    Kim, Dae-Jin
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (04) : 182 - 193
  • [47] Static push-out test on steel and recycled tire rubber-filled concrete composite beams
    Han, Qing-Hua
    Xu, Jie
    Xing, Ying
    Li, Zi-Lin
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (04): : 843 - 860
  • [48] Experimental study on impact behaviour of stud shear connectors in composite beams with profiled steel sheeting
    Huo, Jingsi
    Wang, Haitao
    Li, Long
    Liu, Yanzhi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 161 : 436 - 449
  • [49] Study on mechanical properties of stud shear connectors in steel-UHPC composite structures
    Wu, Fang-Wen
    Feng, Yan-Peng
    Dai, Jun
    Wang, Guang-Qian
    Zhang, Jing-Feng
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (02): : 222 - 234
  • [50] EFFECTS OF STEEL FIBRE REINFORCEMENT ON THE BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL-CONCRETE BEAMS
    Mirzal, O.
    Uy, B.
    ADVANCED STEEL CONSTRUCTION, 2009, 5 (01): : 72 - 95