Experimental study of static and fatigue push-out test on headed stud shear connectors in UHPC composite steel beams

被引:1
|
作者
Gyawali, Mohit [1 ]
Sennah, Khaled [1 ]
Ahmed, Mizan [2 ]
Hamoda, Ahmed [3 ]
机构
[1] Toronto Metropolitan Univ, Civil Engn Dept, 350 Victoria St, Toronto, ON M5B 2K3, Canada
[2] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Bentley, WA 6102, Australia
[3] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
关键词
Ultra high-performance concrete; Composite girders; Shear connectors; Push-out tests; HIGH-STRENGTH; BEHAVIOR;
D O I
10.1016/j.istruc.2024.107923
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite girder bridges utilize shear connectors to connect concrete deck slabs and steel girders. In current practice, the headed shear stud connector is the most used due to its reliability and ease of installation. Several studies are available on the static and fatigue behavior of welded-headed shear studs embedded in normal-strength concrete. However, relatively little is known about the static and fatigue behavior of headed shear connectors in composite beams when shear studs are embedded in ultra-high-performance concrete (UHPC). This study reports a series of pushout results carried out on headed shear connectors embedded in UHPC at pre-fatigue and post-fatigue stages. Six pushout specimens were first tested under static load to collapse. The precast normal-strength concrete slabs in the pushout specimens were reinforced with glass fiber-reinforced polymer (GFRP) bars to promote sustainable construction. This practice, commonly used in Canada, aims to eliminate the corrosion of steel bars caused by de-icing salts used during winter. The results from these tests were used to determine the applied fatigue stress range of another six identical pushout specimens, which were subjected to constant amplitude fatigue loading over 2 million cycles. Results show that the fatigue cycles applied to the specimens prior to testing them to collapse did not alter the failure mode or the crack pattern of the tested specimens. Furthermore, the studied pushout specimens considered 6 different shapes of shear pockets in which the arrangement and spacing of studs were varied. It was found that the studs in a square pocket form yielded a shear capacity of 13.9 % and 16.7 % greater than those for similar studs arranged in a single row-oriented longitudinally and transversally, respectively. The accuracy of the various design formulas specified in design codes in estimating the shear resistance of the tested specimens, as well as empirical formulas proposed to develop load-slip curves of tested specimens, is studied. It was found that the European and Japanese codes significantly underestimated the stud shear capacity, whereas the Canadian code provides a more accurate estimation.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures
    Wang, Jun-Yan
    Guo, Jun-Yuan
    Jia, Liang-Jiu
    Chen, Shi-Ming
    Dong, Yang
    COMPOSITE STRUCTURES, 2017, 170 : 69 - 79
  • [2] Push-Out Test on Shear Connectors Embedded in UHPC
    Kim, Jee Sang
    Park, Sang Hyeok
    Joh, Changbin
    Kwark, Jong D. K.
    Choi, Eun Suk
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 50 - 54
  • [3] Experimental studies of headed stud shear connectors in UHPC Steel composite slabs
    Gao, Xiao-Long
    Wang, Jun-Yan
    Yan, Jia-Bao
    STRUCTURAL ENGINEERING AND MECHANICS, 2020, 74 (05) : 657 - 670
  • [4] Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams
    Qia, Jingjing
    Xie, Zuwei
    Cao, Hua
    Huang, Zhi
    Lv, Weirong
    Shi, Weihua
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 83 (06) : 789 - 798
  • [5] Push-out experimental study on shear connectors in embedded composite beams with notched web
    Li, Xianhui
    Li, Guoqiang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (04): : 78 - 84
  • [6] SHEAR CONNECTORS IN STEEL-CONCRETE COMPOSITE BEAMS FOR BRIDGES .I. STATIC AND FATIGUE TESTS ON PUSH-OUT SPECIMENS
    MAINSTONE, RJ
    MENZIES, JB
    CONCRETE, 1967, 1 (09): : 291 - +
  • [7] Channel shear connectors in composite beams: Push-out tests
    Hosain, M. U.
    Pashan, Amit
    COMPOSITE CONSTRUCTION IN STEEL AND CONCRETE V, 2006, : 501 - +
  • [8] Static behavior of stud shear connectors in high-strength-steel-UHPC composite beams
    Tong, Lewei
    Chen, Luhua
    Wen, Ming
    Xu, Chen
    ENGINEERING STRUCTURES, 2020, 218 (218)
  • [9] Experimental and Numerical Study on the Shear Performance of Short Stud Shear Connectors in Steel-UHPC Composite Beams
    Fang, Zhen
    Fang, Shu
    Liu, Feng
    BUILDINGS, 2022, 12 (04)
  • [10] Full-scale push-out testing of headed stud-steel block connectors in prefabricated steel-concrete composite beams
    Liu, Jiepeng
    Xie, Jincheng
    Xiong, Gang
    Wang, Xuanding
    Zou, Yunhe
    Shu, Rui
    Chen, Frank
    ENGINEERING STRUCTURES, 2023, 285