Experimental study of static and fatigue push-out test on headed stud shear connectors in UHPC composite steel beams

被引:1
|
作者
Gyawali, Mohit [1 ]
Sennah, Khaled [1 ]
Ahmed, Mizan [2 ]
Hamoda, Ahmed [3 ]
机构
[1] Toronto Metropolitan Univ, Civil Engn Dept, 350 Victoria St, Toronto, ON M5B 2K3, Canada
[2] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Bentley, WA 6102, Australia
[3] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
关键词
Ultra high-performance concrete; Composite girders; Shear connectors; Push-out tests; HIGH-STRENGTH; BEHAVIOR;
D O I
10.1016/j.istruc.2024.107923
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite girder bridges utilize shear connectors to connect concrete deck slabs and steel girders. In current practice, the headed shear stud connector is the most used due to its reliability and ease of installation. Several studies are available on the static and fatigue behavior of welded-headed shear studs embedded in normal-strength concrete. However, relatively little is known about the static and fatigue behavior of headed shear connectors in composite beams when shear studs are embedded in ultra-high-performance concrete (UHPC). This study reports a series of pushout results carried out on headed shear connectors embedded in UHPC at pre-fatigue and post-fatigue stages. Six pushout specimens were first tested under static load to collapse. The precast normal-strength concrete slabs in the pushout specimens were reinforced with glass fiber-reinforced polymer (GFRP) bars to promote sustainable construction. This practice, commonly used in Canada, aims to eliminate the corrosion of steel bars caused by de-icing salts used during winter. The results from these tests were used to determine the applied fatigue stress range of another six identical pushout specimens, which were subjected to constant amplitude fatigue loading over 2 million cycles. Results show that the fatigue cycles applied to the specimens prior to testing them to collapse did not alter the failure mode or the crack pattern of the tested specimens. Furthermore, the studied pushout specimens considered 6 different shapes of shear pockets in which the arrangement and spacing of studs were varied. It was found that the studs in a square pocket form yielded a shear capacity of 13.9 % and 16.7 % greater than those for similar studs arranged in a single row-oriented longitudinally and transversally, respectively. The accuracy of the various design formulas specified in design codes in estimating the shear resistance of the tested specimens, as well as empirical formulas proposed to develop load-slip curves of tested specimens, is studied. It was found that the European and Japanese codes significantly underestimated the stud shear capacity, whereas the Canadian code provides a more accurate estimation.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Research on Shear Capacity of Long Stud Connectors for Steel-UHPC Composite Beams
    Chen Z.
    Ma B.
    Gao L.
    Bridge Construction, 2023, 53 (06) : 79 - 85
  • [22] Push-out test of headed stud connectors subjected to freeze-thaw cycles and artificial corrosion
    Xiao, Lin
    Wei, Xing
    Dai, Ljun
    Kang, Zhirui
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 376
  • [23] Static behavior of large stud shear connectors in steel-UHPC composite structures
    Wang, Jingquan
    Qi, Jianan
    Tong, Teng
    Xu, Qizhi
    Xiu, Hongliang
    ENGINEERING STRUCTURES, 2019, 178 : 534 - 542
  • [24] HIGH TEMPERATURE PUSH-OUT TESTS ON DEMOUNTABLE SHEAR CONNECTORS OF STEEL-CONCRETE COMPOSITE BEAMS
    Mansilla, Roberto
    Espinós, Ana
    Payá-Faforteza, Ignacio
    Odenbreit, Christoph
    Romero, Manuel L.
    ce/papers, 2023, 6 (3-4) : 2074 - 2079
  • [25] Push-out tests of shear connectors for new fully assembled steel-concrete composite beams
    Hou H.-T.
    Zang Z.-Y.
    Lu Y.-X.
    Liu J.-W.
    Ji K.-F.
    Wang Y.-M.
    Gongcheng Lixue/Engineering Mechanics, 2020, 37 (02): : 201 - 210
  • [26] Capacities of headed stud shear connectors in composite steel beams with precast hollowcore slabs
    Lam, Dennis
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (09) : 1160 - 1174
  • [27] Experimental study on grouped stud shear connectors in precast steel-UHPC composite bridge
    Ding, Jingnan
    Zhu, Jinsong
    Kang, Jingfu
    Wang, Xiuce
    ENGINEERING STRUCTURES, 2021, 242
  • [28] Push-out test of square CFST columns with steel plate shear connectors
    Qiao Q.
    Zhang W.
    Cao W.
    Dong H.
    2018, Huazhong University of Science and Technology (46): : 108 - 115
  • [29] Push-out tests on headed studs and lattice shear connectors welded to louver steel plate
    Im, Chae-Rim
    Kim, Sanghee
    Mun, Ju-Hyun
    Yang, Keun-Hyeok
    Sim, Jae-il
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 369
  • [30] EXPERIMENTAL STUDIES ON THE BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL CONCRETE BEAMS UNDER ELEVATED TEMPERATURES
    Mirza, O.
    Uy, B.
    Krezo, S.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 467 - 473