Experimental study of static and fatigue push-out test on headed stud shear connectors in UHPC composite steel beams

被引:1
|
作者
Gyawali, Mohit [1 ]
Sennah, Khaled [1 ]
Ahmed, Mizan [2 ]
Hamoda, Ahmed [3 ]
机构
[1] Toronto Metropolitan Univ, Civil Engn Dept, 350 Victoria St, Toronto, ON M5B 2K3, Canada
[2] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Bentley, WA 6102, Australia
[3] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
关键词
Ultra high-performance concrete; Composite girders; Shear connectors; Push-out tests; HIGH-STRENGTH; BEHAVIOR;
D O I
10.1016/j.istruc.2024.107923
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite girder bridges utilize shear connectors to connect concrete deck slabs and steel girders. In current practice, the headed shear stud connector is the most used due to its reliability and ease of installation. Several studies are available on the static and fatigue behavior of welded-headed shear studs embedded in normal-strength concrete. However, relatively little is known about the static and fatigue behavior of headed shear connectors in composite beams when shear studs are embedded in ultra-high-performance concrete (UHPC). This study reports a series of pushout results carried out on headed shear connectors embedded in UHPC at pre-fatigue and post-fatigue stages. Six pushout specimens were first tested under static load to collapse. The precast normal-strength concrete slabs in the pushout specimens were reinforced with glass fiber-reinforced polymer (GFRP) bars to promote sustainable construction. This practice, commonly used in Canada, aims to eliminate the corrosion of steel bars caused by de-icing salts used during winter. The results from these tests were used to determine the applied fatigue stress range of another six identical pushout specimens, which were subjected to constant amplitude fatigue loading over 2 million cycles. Results show that the fatigue cycles applied to the specimens prior to testing them to collapse did not alter the failure mode or the crack pattern of the tested specimens. Furthermore, the studied pushout specimens considered 6 different shapes of shear pockets in which the arrangement and spacing of studs were varied. It was found that the studs in a square pocket form yielded a shear capacity of 13.9 % and 16.7 % greater than those for similar studs arranged in a single row-oriented longitudinally and transversally, respectively. The accuracy of the various design formulas specified in design codes in estimating the shear resistance of the tested specimens, as well as empirical formulas proposed to develop load-slip curves of tested specimens, is studied. It was found that the European and Japanese codes significantly underestimated the stud shear capacity, whereas the Canadian code provides a more accurate estimation.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Static behavior of push-out specimen with multi-row stud connectors
    Su, Qingtian
    Han, Xu
    Ren, Fei
    Tongji Daxue Xuebao/Journal of Tongji University, 2014, 42 (07): : 1011 - 1016
  • [32] Push-out test of the perforated corrugated plate shear connectors in steel-concrete composite structure
    School of Transportation, Southeast University, Nanjing
    Jiangsu, China
    Chang'an Daxue Xuebao, 2 (75-82):
  • [33] Finite element modeling of push-out tests for large stud shear connectors
    Nguyen, Huu Thanh
    Kim, Seung Eock
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (10-11) : 1909 - 1920
  • [34] Static behavior of stud shear connectors with initial damage in steel-UHPC composite bridges
    Qi, Jianan
    Tang, Yiqun
    Cheng, Zhao
    Xu, Rui
    Wang, Jingquan
    ADVANCES IN CONCRETE CONSTRUCTION, 2020, 9 (04) : 413 - 421
  • [35] Push-out tests on three innovative shear connectors for composite cold-formed steel concrete beams
    Bamaga, S. O.
    Tahir, M. M.
    Tan, C. S.
    Shek, P. N.
    Aghlara, R.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 223 : 288 - 298
  • [36] SMALL-SCALE PUSH-OUT TESTS ON WELDED STUD SHEAR CONNECTORS
    DAVIES, C
    CONCRETE, 1967, 1 (09): : 311 - &
  • [37] Research on the static load mechanical properties of PBL shear connectors' push-out test
    Xiao, Lin
    Li, Xiaozhen
    Wei, Xing
    Zhongguo Tiedao Kexue/China Railway Science, 2010, 31 (03): : 15 - 21
  • [38] Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures
    Mirza, O.
    Uy, B.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (03) : 662 - 674
  • [39] Push-out performance of stud/channel steel connectors in UHPC for new precast concrete beam-slab connections
    Zhang, Jianxin
    Zhang, Tingwei
    Yuan, Weitao
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (11) : 1901 - 1921
  • [40] BEHAVIOR OF HEADED STUDS IN COMPOSITE BEAMS - PUSH-OUT TESTS
    JAYAS, BS
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1988, 15 (02) : 240 - 253