High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference

被引:0
|
作者
Li, Jin [1 ]
Tang, Suo-han [1 ]
Zhu, Xiangkun [1 ]
Ma, Jian-xiong [1 ]
Zhu, Zhiyong [1 ]
Yan, Bin [1 ]
机构
[1] Chinese Acad Geol Sci, Inst Geol, MNR Key Lab Isotope Geol, Beijing 100037, Peoples R China
基金
美国国家科学基金会;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM ISOTOPES; SOUTHERN-OCEAN; FRACTIONATION; POLLUTION; SEAWATER; SOILS; ZINC; ABUNDANCES; SEPARATION;
D O I
10.1039/d4ja00357h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous studies have reported that even low concentrations of Sn can lead to biased Cd isotopic measurements using MC-ICP-MS. In this paper, we propose a novel method of Cd isotopic analysis involving use of a Cd-106-Cd-111 double spike. To eliminate isobaric interference from Sn-114, we use Cd-113 together with Cd-106, Cd-110, and Cd-111 to obtain delta Cd-113/110, and then calculate delta Cd-114/110 as 1.33 x delta Cd-113/110. We find that when Sn/Cd is <= 2.5 in sample solutions, delta Cd-114/110 values are not affected by Sn, which behaves as a matrix element rather than causing isobaric interference. Cd isotopic measurements are not sensitive to the molarities of diluted HNO3 or the Cd concentration. Additionally, when Mo/Cd, Ni/Cd, and Se/Cd are <= 1 in sample solutions, Cd isotopic measurements are not significantly affected. Instead, when Zn/Cd is >0.1, In/Cd > 0.05, and Pd/Cd > 5 x 10(-3), the measured delta Cd-114/110 values deviate significantly from zero. However, Zn and In can be eliminated completely, and Pd was not detected in any Cd eluents. The delta Cd-114/110 values of three standard solutions (Spex-CUGB, BAM I012, and M & uuml;nster) and four geochemical reference materials (SGR-1b, BCR-2, GSD-7a, and NIST 2711a) were measured and found to be in close agreement with published results (with 2SD and ranges for all data of less than 0.090 and 0.120, respectively). This indicates that the data obtained by our double spike method are precise and reliable. Additionally, our new technique can help to simplify separation procedures, thus saving time and reducing the quantities of acid required.
引用
收藏
页码:3106 / 3115
页数:10
相关论文
共 50 条
  • [31] High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
    Liu, Shanke
    Li, Wenjun
    Su, Benxun
    Gao, Bingyu
    Wang, Jing
    Wang, Changle
    Luo, Yang
    Yan, Lizhi
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 656 - 666
  • [32] High-precision iron isotopic measurements in low resolution using collision cell (CC)-MC-ICP-MS
    Wang, Jing
    Tang, Dong-Mei
    Su, Ben-Xun
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Chen, Kai-Yun
    Bao, Zhi-An
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (09) : 1869 - 1875
  • [33] High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
    Peng, Huan
    He, Dong
    Guo, Rui
    Liu, Xing
    Belshaw, Nicholas S.
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (02) : 390 - 398
  • [34] High-Precision Mass-Dependent Molybdenum Isotope Variations in Magmatic Rocks Determined by Double-Spike MC-ICP-MS
    Willbold, Matthias
    Hibbert, Kate
    Lai, Yi-Jen
    Freymuth, Heye
    Hin, Remco C.
    Coath, Christopher
    Vils, Flurin
    Elliott, Tim
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2016, 40 (03) : 389 - 403
  • [35] An optimal separation method for high-precision K isotope analysis by using MC-ICP-MS with a dummy bucket
    Li, Xiaoqiang
    Han, Guilin
    Zhang, Qian
    Miao, Zhuang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) : 1330 - 1339
  • [36] High-Sensitivity Measurement of Cr Isotopes by Double Spike MC-ICP-MS at the 10 ng Level
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Johnson, Thomas M.
    Han, Guilin
    ANALYTICAL CHEMISTRY, 2020, 92 (01) : 1463 - 1469
  • [37] Emerging applications of high-precision Cu isotopic analysis by MC-ICP-MS
    Sullivan, Kaj V.
    Kidder, James A.
    Junqueira, Tassiane P.
    Vanhaecke, Frank
    Leybourne, Matthew I.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 838
  • [38] High-precision analysis of potassium isotopes by MC-ICP-MS without collision cell using cool plasma technique in low-resolution mode
    Gu, Hai-Ou
    Sun, He
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (11) : 2545 - 2552
  • [39] Analysis of high-precision vanadium isotope ratios by medium resolution MC-ICP-MS
    Nielsen, Sune G.
    Owens, Jeremy D.
    Horner, Tristan J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 531 - 536
  • [40] High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS
    Weis, Dominique
    Kieffer, Bruno
    Maerschalk, Claude
    Barling, Jane
    de Jong, Jeroen
    Williams, Gwen A.
    Hanano, Diane
    Pretorius, Wilma
    Mattielli, Nadine
    Scoates, James S.
    Goolaerts, Arnaud
    Friedman, Richard M.
    Mahoney, J. Brian
    GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2006, 7