High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference

被引:0
|
作者
Li, Jin [1 ]
Tang, Suo-han [1 ]
Zhu, Xiangkun [1 ]
Ma, Jian-xiong [1 ]
Zhu, Zhiyong [1 ]
Yan, Bin [1 ]
机构
[1] Chinese Acad Geol Sci, Inst Geol, MNR Key Lab Isotope Geol, Beijing 100037, Peoples R China
基金
美国国家科学基金会;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM ISOTOPES; SOUTHERN-OCEAN; FRACTIONATION; POLLUTION; SEAWATER; SOILS; ZINC; ABUNDANCES; SEPARATION;
D O I
10.1039/d4ja00357h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous studies have reported that even low concentrations of Sn can lead to biased Cd isotopic measurements using MC-ICP-MS. In this paper, we propose a novel method of Cd isotopic analysis involving use of a Cd-106-Cd-111 double spike. To eliminate isobaric interference from Sn-114, we use Cd-113 together with Cd-106, Cd-110, and Cd-111 to obtain delta Cd-113/110, and then calculate delta Cd-114/110 as 1.33 x delta Cd-113/110. We find that when Sn/Cd is <= 2.5 in sample solutions, delta Cd-114/110 values are not affected by Sn, which behaves as a matrix element rather than causing isobaric interference. Cd isotopic measurements are not sensitive to the molarities of diluted HNO3 or the Cd concentration. Additionally, when Mo/Cd, Ni/Cd, and Se/Cd are <= 1 in sample solutions, Cd isotopic measurements are not significantly affected. Instead, when Zn/Cd is >0.1, In/Cd > 0.05, and Pd/Cd > 5 x 10(-3), the measured delta Cd-114/110 values deviate significantly from zero. However, Zn and In can be eliminated completely, and Pd was not detected in any Cd eluents. The delta Cd-114/110 values of three standard solutions (Spex-CUGB, BAM I012, and M & uuml;nster) and four geochemical reference materials (SGR-1b, BCR-2, GSD-7a, and NIST 2711a) were measured and found to be in close agreement with published results (with 2SD and ranges for all data of less than 0.090 and 0.120, respectively). This indicates that the data obtained by our double spike method are precise and reliable. Additionally, our new technique can help to simplify separation procedures, thus saving time and reducing the quantities of acid required.
引用
收藏
页码:3106 / 3115
页数:10
相关论文
共 50 条
  • [21] Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
    Shuai, Kang
    Li, Weiqiang
    Hui, Hejiu
    ANALYTICAL CHEMISTRY, 2020, 92 (07) : 4820 - 4828
  • [22] High precision osmium stable isotope measurements by double spike MC-ICP-MS and N-TIMS
    Nanne, Josefine A. M.
    Millet, Marc-Alban
    Burton, Kevin W.
    Dale, Chris W.
    Nowell, Geoff M.
    Williams, Helen M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (04) : 749 - 765
  • [23] High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
    Tan, Decan
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Lu, Zhuo
    Xu, Wenpo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 713 - 727
  • [24] Accurate and high-precision measurement of lithium isotopes in two reference materials by MC-ICP-MS
    Millot, R
    Guerrot, C
    Vigier, N
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2004, 28 (01) : 153 - 159
  • [25] High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS
    Gao, Bing-Yu
    Su, Ben-Xun
    Li, Wen-Jun
    Yuan, Meng
    Sun, Jian
    Zhao, Ye
    Liu, Xia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2111 - 2121
  • [26] High precision cadmium isotopic measurements by MC-ICP-MS
    Cloquet, C
    Carignan, J
    Libourel, G
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A144 - A144
  • [27] High precision Rb isotope measurements by MC-ICP-MS
    Hu, Xia
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2744 - 2755
  • [28] Stable Cr isotope ratio measurements using a double-spike method and high-resolution MC-ICP-MS
    von Blanckenburg, F
    Schoenberg, R
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A867 - A867
  • [29] High resolution MC-ICP-MS measurements of Fe isotopes in granitoids
    Freydier, R
    Poitrasson, F
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A681 - A681
  • [30] High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
    Wang, Jing
    Su, Ben-Xun
    Tang, Dong-Mei
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2589 - 2598