High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference

被引:0
|
作者
Li, Jin [1 ]
Tang, Suo-han [1 ]
Zhu, Xiangkun [1 ]
Ma, Jian-xiong [1 ]
Zhu, Zhiyong [1 ]
Yan, Bin [1 ]
机构
[1] Chinese Acad Geol Sci, Inst Geol, MNR Key Lab Isotope Geol, Beijing 100037, Peoples R China
基金
美国国家科学基金会;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM ISOTOPES; SOUTHERN-OCEAN; FRACTIONATION; POLLUTION; SEAWATER; SOILS; ZINC; ABUNDANCES; SEPARATION;
D O I
10.1039/d4ja00357h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous studies have reported that even low concentrations of Sn can lead to biased Cd isotopic measurements using MC-ICP-MS. In this paper, we propose a novel method of Cd isotopic analysis involving use of a Cd-106-Cd-111 double spike. To eliminate isobaric interference from Sn-114, we use Cd-113 together with Cd-106, Cd-110, and Cd-111 to obtain delta Cd-113/110, and then calculate delta Cd-114/110 as 1.33 x delta Cd-113/110. We find that when Sn/Cd is <= 2.5 in sample solutions, delta Cd-114/110 values are not affected by Sn, which behaves as a matrix element rather than causing isobaric interference. Cd isotopic measurements are not sensitive to the molarities of diluted HNO3 or the Cd concentration. Additionally, when Mo/Cd, Ni/Cd, and Se/Cd are <= 1 in sample solutions, Cd isotopic measurements are not significantly affected. Instead, when Zn/Cd is >0.1, In/Cd > 0.05, and Pd/Cd > 5 x 10(-3), the measured delta Cd-114/110 values deviate significantly from zero. However, Zn and In can be eliminated completely, and Pd was not detected in any Cd eluents. The delta Cd-114/110 values of three standard solutions (Spex-CUGB, BAM I012, and M & uuml;nster) and four geochemical reference materials (SGR-1b, BCR-2, GSD-7a, and NIST 2711a) were measured and found to be in close agreement with published results (with 2SD and ranges for all data of less than 0.090 and 0.120, respectively). This indicates that the data obtained by our double spike method are precise and reliable. Additionally, our new technique can help to simplify separation procedures, thus saving time and reducing the quantities of acid required.
引用
收藏
页码:3106 / 3115
页数:10
相关论文
共 50 条
  • [41] High-precision Copper and Zinc Isotopic Measurements in Igneous Rock Standards Using Large-geometry MC-ICP-MS
    Zhu, Yangtao
    Li, Ming
    Wang, Zaicong
    Zou, Zongqi
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chai, Xinna
    ATOMIC SPECTROSCOPY, 2019, 40 (06) : 206 - 214
  • [42] Sn Isotopic Values in Ten Geological Reference Materials by Double-Spike MC-ICP-MS
    Wang, Zhao-Yang
    Luo, Zhen-Yu
    Zhang, Le
    Liu, Jun-Jie
    Li, Jie
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2022, 46 (03) : 547 - 561
  • [43] Measurement on high-precision boron isotope of silicate materials by a single column purification method and MC-ICP-MS
    Wei Gangjian
    Wei Jingxian
    Liu Ying
    Ke Ting
    Ren Zhongyuan
    Ma Jinlong
    Xu Yigang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 606 - 612
  • [44] High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS
    Bai, Jiang-Hao
    Lin, Mang
    Zhong, Song-Xiong
    Deng, Yi-Nan
    Zhang, Le
    Luo, Kai
    Wu, Hao
    Ma, Jin-Long
    Wei, Gang-Jian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 629 - 637
  • [45] Ion exchange chromatography and high precision isotopic measurements of zirconium by MC-ICP-MS
    Schönbächler, M
    Rehkämper, M
    Lee, DC
    Halliday, AN
    ANALYST, 2004, 129 (01) : 32 - 37
  • [46] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    Li, Jin
    Tang, Suohan
    Zhu, Xiangkun
    Ma, Jianxiong
    Zhao, Xinmiao
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2022, 96 (02) : 517 - 524
  • [47] High precision measurements of gallium isotopic compositions in geological materials by MC-ICP-MS
    Zhang, Ting
    Zhou, Lian
    Yang, Lu
    Wang, Qian
    Feng, Lan-ping
    Liu, Yong-Sheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (08) : 1673 - 1679
  • [48] Optimization of the sample preparation and measurement protocol for the analysis of uranium isotopes by MC-ICP-MS without spike addition
    Rovan, Leja
    Strok, Marko
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1882 - 1891
  • [49] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    LI Jin
    TANG Suohan
    ZHU Xiangkun
    MA Jianxiong
    ZHAO Xinmiao
    ActaGeologicaSinica(EnglishEdition), 2022, 96 (02) : 517 - 524
  • [50] Ultra-precise titanium stable isotope measurements by double-spike high resolution MC-ICP-MS
    Millet, Marc-Alban
    Dauphas, Nicolas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) : 1444 - 1458