High-Sensitivity Measurement of Cr Isotopes by Double Spike MC-ICP-MS at the 10 ng Level

被引:35
|
作者
Wu, Guangliang [1 ]
Zhu, Jian-Ming [1 ,2 ]
Wang, Xiangli [3 ,4 ]
Johnson, Thomas M. [5 ]
Han, Guilin [1 ]
机构
[1] China Univ Geosci Beijing, State Key Lab Geol Proc & Mineral Resources, Beijing 100083, Peoples R China
[2] Chinese Acad Sci, State Key Lab Environm Geochem, Inst Geochem, Guiyang 550081, Peoples R China
[3] Univ S Alabama, Dept Marine Sci, Mobile, AL 36688 USA
[4] Dauphin Isl Sea Lab, Dauphin Isl, AL 36528 USA
[5] Univ Illinois, Dept Geol, 3081 Nat Hist Bldg, Urbana, IL 61801 USA
基金
中国国家自然科学基金;
关键词
IONIZATION MASS-SPECTROMETRY; CHROMIUM ISOTOPES; HEXAVALENT CHROMIUM; FRACTIONATION; SEAWATER; SAMPLES; RATIOS; GROUNDWATER; PURIFICATION; SYSTEMATICS;
D O I
10.1021/acs.analchem.9b04704
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-sensitivity and high-precision (2 SD <= 0.06 parts per thousand) measurement of chromium (Cr) isotopes at the 10 ng level was successfully carried out using double spike multiple-collector inductively couple plasma mass spectrometry (MC-ICP-MS). To enhance the signal sensitivity and stability, the Aridus II desolvating nebulizer system was improved by placing its waste gas trap bottle in an ice chamber (5 degrees C cold trap). This setup, beyond Cr isotope analysis, can be applied to most heavy metal isotope measurements. The sensitivity of the Cr-52 signal is >= 300 V mg(-1) L (with a 10(11)Omega amplifier and a 110 mu L min(-1) uptake rate), an enhancement of >= 1.5 times compared to the Aridus II without the cold trap. In addition, the relative standard deviation of the Cr-52 signal varied <= 4% over 8 h, demonstrating high stability. The delta Cr-53 values of common geological reference materials determined using 10 ng of Cr are in excellent agreement with results measured at 25 ng and 50 ng and are consistent with previous determinations, validating the accurate and precise Cr isotope ratio measurements. An empirical method is proposed to correct for the residual (after subtraction) effect of Fe interference on delta Cr-53 determination. This method relies on a linear relationship between the [Fe]/[Cr] and delta Cr-53 shift within one analytical session. Finally, we report the delta Cr-53 values of 19 new reference materials, ranging from -0.44 parts per thousand to 0.49 parts per thousand. Among them, GSS-7 (-0.44 +/- 0.02 parts per thousand, 2 SD, n = 5), GSS-4 (0.48 +/- 0.02 parts per thousand, 2 SD, n = 5), and GSD-10 (0.49 +/- 0.05 parts per thousand, 2 SD, n = 5) can be used as candidate reference materials for interlaboratory comparisons to complement existing ones that are mostly isotopically unfractionated from the bulk silicate earth.
引用
收藏
页码:1463 / 1469
页数:7
相关论文
共 50 条
  • [1] Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS
    Zhu, Hong-Gang
    Zhu, Jian-Ming
    Tan, Decan
    Lin, Xuan
    Lu, Kaite
    Yang, Wen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (05) : 1063 - 1075
  • [2] An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS
    Zhu, Jian-Ming
    Wu, Guangliang
    Wang, Xiangli
    Han, Guilin
    Zhang, Lixin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 809 - 821
  • [3] High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
    Tan, Decan
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Lu, Zhuo
    Xu, Wenpo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 713 - 727
  • [4] A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Tan, Decan
    Wang, Shui-Jiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1639 - 1651
  • [5] High-Precision Sn Isotopic Measurement in Geological Materials by Double-Spike MC-ICP-MS
    Song, Wenrui
    Zhu, Chuanwei
    Wen, Hanjie
    Zhang, Yuxu
    Liu, Zerui
    Zhou, Meifu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [6] High-precision measurement of Ag isotopes for silicate rocks by MC-ICP-MS
    Fang, Yuan
    Wen, Qiu-Yu
    Xiao, Zi-Cong
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (07) : 1750 - 1758
  • [7] High-precision measurement of Ag isotopes for silicate rocks by MC-ICP-MS
    Fang, Yuan
    Wen, Qiu-Yu
    Xiao, Zi-Cong
    Yu, Hui-Min
    Huang, Fang
    Journal of Analytical Atomic Spectrometry, 1600, 39 (07): : 1750 - 1758
  • [8] Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS
    Bonnand, Pierre
    Parkinson, Ian J.
    James, Rachael H.
    Karjalainen, Anne-Mari
    Fehr, Manuela A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 528 - 535
  • [9] The stable Cr isotope inventory of solid Earth reservoirs determined by double spike MC-ICP-MS
    Schoenberg, R.
    Zink, S.
    Staubwasser, M.
    von Blanckenburg, F.
    CHEMICAL GEOLOGY, 2008, 249 (3-4) : 294 - 306
  • [10] Optimization of the sample preparation and measurement protocol for the analysis of uranium isotopes by MC-ICP-MS without spike addition
    Rovan, Leja
    Strok, Marko
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1882 - 1891