Water gradient manipulation through the polymer electrolyte membrane of an operating microfluidic water electrolyzer

被引:1
|
作者
Krause, Kevin [1 ,2 ]
Crete-Laurence, Adele [1 ,2 ]
Michau, Dominique [3 ]
Clisson, Gerald [4 ]
Battaglia, Jean-Luc [1 ,2 ]
Chevalier, Stephane [1 ,2 ]
机构
[1] Univ Bordeaux, CNRS, UMR 5295, Bordeaux INP,I2M, F-33400 Talence, France
[2] CNRS, UMR 5295, Arts & Metiers Inst Technol, Bordeaux INP,I2M, F-33400 Talence, France
[3] Univ Bordeaux, CNRS, UMR 5026, ICMCB,Bordeaux INP, F-33600 Pessac, France
[4] Univ Bordeaux, CNRS, UMR 5258, Syensqo,LOF, F-33600 Pessac, France
关键词
Microfluidics; Polymer electrolyte membrane; Water electrolysis; Operando imaging; Infrared spectroscopy; Distribution of relaxation times; HYDROGEN-PRODUCTION; NAFION; TRANSPORT; HYDRATION;
D O I
10.1016/j.jpowsour.2024.235297
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The key component of a polymer electrolyte membrane (PEM) water splitting electrolyzer is its membrane. Despite decades of research, the transport phenomena occurring within the membrane during electrolysis - which are vital to the device's efficiency - have yet to be fully understood. In this work, controlling the anolyte concentration can effectively be used to tune the PEM water gradient, but it comes with a tradeoff in electrochemical performance. Infrared (IR) imaging is coupled with electrochemical impedance spectroscopy and distribution of relaxation times to elucidate the relationship between membrane hydration and ohmic, kinetic, and mass transport losses. Varied H2SO4 anolyte concentrations manifested water diffusion gradients through the PEM of the electrolyzer, where the strongest water diffusion gradients | Delta lambda(fit) | (relative to open circuit voltage) were observed for the most concentrated anolyte. However, tuning the anolyte concentration came with a tradeoff between a lower ohmic resistance (from 4.4 Omega cm(-2) to 4.0 Omega cm(-2) for 0.1 mol L-1 to 1.0 mol L-1 H2SO4 anolyte) and higher kinetic and mass transport losses accompanied by increasingly unstable performance. These findings showcase the potential of IR imaging when coupled with a microfluidic PEM electrolyzer and electrochemical characterization techniques, and the influence of anolyte concentration for manipulating the PEM water gradient.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Study on gas accumulation in polymer electrolyte membrane water electrolyzer considering two-phase flow
    Na, Youngseung
    Kim, Young Ki
    Kim, Sangwon
    Kim, Dong Kyu
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 154
  • [22] Accelerated stress test of polymer electrolyte membrane water electrolyzer via solar power generation condition
    Choi, Baeck B.
    Jo, Jae Hyeon
    Yoo, Young Sung
    Jeon, Sang-Yun
    Lee, Taehee
    Choi, Yeong-Jun
    Chung, Dong Young
    Lee, Eung-Jun
    Yoo, Sung Jong
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2023, 57
  • [23] Durability of irradiated polymers in solid-polymer-electrolyte water electrolyzer
    Iwai, Y
    Yamanishi, T
    Nishi, M
    Yagi, T
    Tamada, M
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2005, 42 (07) : 636 - 642
  • [24] The long-term stability of the solid polymer electrolyte water electrolyzer
    Inazumi, C
    Mori, H
    Kato, M
    Maezawa, S
    Sawai, N
    Oguro, K
    Takenaka, H
    HYDROGEN ENERGY PROGRESS XI, VOLS 1-3, 1996, : 741 - 746
  • [25] Ni Nano-particle Encapsulated in Hollow Carbon Sphere Electrocatalyst in Polymer Electrolyte Membrane Water Electrolyzer
    Chattopadhyay, Jayeeta
    Pathak, Tara Sankar
    Srivastava, R.
    Singh, A. C.
    ELECTROCHIMICA ACTA, 2015, 167 : 429 - 438
  • [26] Adsorption of water vapor on a polymer electrolyte membrane
    Hatakenaka, Satoshi
    Takata, Hiroki
    Mizuno, Nobukazu
    Mamiya, Yuko
    Nishikawa, Masabumi
    Fukada, Satoshi
    Morishima, Makoto
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (13) : 3368 - 3372
  • [27] Thermal and electrochemical analyses of a polymer electrolyte membrane electrolyzer
    Nafchi, F. Moradi
    Afshari, E.
    Baniasadi, E.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (95) : 40172 - 40183
  • [28] Water transport coefficient distribution through the membrane in a polymer electrolyte fuel cell
    Liu, Fuqiang
    Lu, Guoqiang
    Wang, Chao-Yang
    JOURNAL OF MEMBRANE SCIENCE, 2007, 287 (01) : 126 - 131
  • [29] Optimization of operating parameters of a polymer exchange membrane electrolyzer
    Toghyani, Somayeh
    Fakhradini, Soheil
    Afshari, Ebrahim
    Baniasadi, Ehsan
    Jamalabadi, Mohammad Yaghoub Abdollahzadeh
    Shadloo, Mostafa Safdari
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (13) : 6403 - 6414
  • [30] Oxygen bubble transport in a porous transport layer of polymer electrolyte water electrolyzer
    Jeon, Dong Hyup
    Kim, Sangwon
    Kim, MinJoong
    Lee, Changsoo
    Cho, Hyun-Seok
    JOURNAL OF POWER SOURCES, 2023, 553