Water gradient manipulation through the polymer electrolyte membrane of an operating microfluidic water electrolyzer

被引:1
|
作者
Krause, Kevin [1 ,2 ]
Crete-Laurence, Adele [1 ,2 ]
Michau, Dominique [3 ]
Clisson, Gerald [4 ]
Battaglia, Jean-Luc [1 ,2 ]
Chevalier, Stephane [1 ,2 ]
机构
[1] Univ Bordeaux, CNRS, UMR 5295, Bordeaux INP,I2M, F-33400 Talence, France
[2] CNRS, UMR 5295, Arts & Metiers Inst Technol, Bordeaux INP,I2M, F-33400 Talence, France
[3] Univ Bordeaux, CNRS, UMR 5026, ICMCB,Bordeaux INP, F-33600 Pessac, France
[4] Univ Bordeaux, CNRS, UMR 5258, Syensqo,LOF, F-33600 Pessac, France
关键词
Microfluidics; Polymer electrolyte membrane; Water electrolysis; Operando imaging; Infrared spectroscopy; Distribution of relaxation times; HYDROGEN-PRODUCTION; NAFION; TRANSPORT; HYDRATION;
D O I
10.1016/j.jpowsour.2024.235297
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The key component of a polymer electrolyte membrane (PEM) water splitting electrolyzer is its membrane. Despite decades of research, the transport phenomena occurring within the membrane during electrolysis - which are vital to the device's efficiency - have yet to be fully understood. In this work, controlling the anolyte concentration can effectively be used to tune the PEM water gradient, but it comes with a tradeoff in electrochemical performance. Infrared (IR) imaging is coupled with electrochemical impedance spectroscopy and distribution of relaxation times to elucidate the relationship between membrane hydration and ohmic, kinetic, and mass transport losses. Varied H2SO4 anolyte concentrations manifested water diffusion gradients through the PEM of the electrolyzer, where the strongest water diffusion gradients | Delta lambda(fit) | (relative to open circuit voltage) were observed for the most concentrated anolyte. However, tuning the anolyte concentration came with a tradeoff between a lower ohmic resistance (from 4.4 Omega cm(-2) to 4.0 Omega cm(-2) for 0.1 mol L-1 to 1.0 mol L-1 H2SO4 anolyte) and higher kinetic and mass transport losses accompanied by increasingly unstable performance. These findings showcase the potential of IR imaging when coupled with a microfluidic PEM electrolyzer and electrochemical characterization techniques, and the influence of anolyte concentration for manipulating the PEM water gradient.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] THROUGH-PLANE WATER DISTRIBUTION IN A POLYMER ELECTROLYTE FUEL CELL AT VARIOUS OPERATING TEMPERATURES
    Wang, Yun
    Chen, Ken S.
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 5: FUEL CELLS, GAS TURBINES, HEAT PIPES, JET IMPINGEMENT, RADIATION, 2010, : 109 - 114
  • [42] AN ANALYSIS OF THE WATER TRANSPORT PROPERTIES OF POLYMER ELECTROLYTE MEMBRANE
    Aotani, K.
    Miyazaki, S.
    Kubo, N.
    Katsuta, M.
    PROTON EXCHANGE MEMBRANE FUEL CELLS 8, PTS 1 AND 2, 2008, 16 (02): : 341 - +
  • [43] Water transport in polymer electrolyte membrane fuel cells
    Jiao, Kui
    Li, Xianguo
    PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2011, 37 (03) : 221 - 291
  • [44] Softening of water in electrolyzer with ceramic membrane
    Goncharuk, V.V., 2005, Naukova dumka (27):
  • [45] The effect of membrane on an alkaline water electrolyzer
    Liu, Zengcai
    Sajjad, Syed Dawar
    Gao, Yan
    Yang, Hongzhou
    Kaczur, Jerry J.
    Masel, Richard I.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (50) : 29661 - 29665
  • [46] Numerical Analysis of Water Transport Through the Membrane Electrolyte Assembly of a Polymer Exchange Membrane Fuel Cell
    Zhang, Xu
    Song, Datong
    Wang, Qianpu
    Huang, Cheng
    Liu, Zhong-Sheng
    Shah, A. A.
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2010, 7 (02): : 0210091 - 02100914
  • [47] MXenes in polymer electrolyte membrane hydrogen fuel and electrolyzer cells
    Boretti, Alberto
    Castelletto, Stefania
    CERAMICS INTERNATIONAL, 2022, 48 (23) : 34190 - 34198
  • [48] Development of high performance solid polymer electrolyte water electrolyzer in WE-NET
    Yamaguchi, M
    Okisawa, K
    Nakanori, T
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 1958 - 1965
  • [49] Elucidating the Role of Hydroxide Electrolyte on Anion-Exchange-Membrane Water Electrolyzer Performance
    Liu, Jiangjin
    Kang, Zhenye
    Li, Dongguo
    Pak, Magnolia
    Alia, Shaun M.
    Fujimoto, Cy
    Bender, Guido
    Kim, Yu Seung
    Weber, Adam Z.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [50] Effect of flow-field pattern and flow configuration on the performance of a polymer-electrolyte-membrane water electrolyzer at high temperature
    Li, Hua
    Nakajima, Hironori
    Inada, Akiko
    Ito, Kohei
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (18) : 8600 - 8610