A novel miniaturized roller pump circuit for simulation of extracorporeal circulation

被引:0
|
作者
Hjarpe, Anders K. [1 ,2 ]
Jeppsson, Anders [3 ,4 ]
Lannemyr, Lukas [2 ,5 ]
Pernbro, Fredrik [2 ,6 ]
Hesse, Camilla [7 ,8 ]
Romlin, Birgitta [2 ,6 ]
机构
[1] Sahlgrens Univ Hosp, Dept Perfus, SE-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Inst Clin Sci, Sahlgrenska Acad, Dept Anaesthes & Intens Care, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Med, Sahlgrenska Acad, Dept Mol & Clin Med, Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Dept Cardiothorac Anaesthes, Gothenburg, Sweden
[6] Queen Silv Childrens Hosp, Dept Paediat Anaesthes & Intens Care, Gothenburg, Sweden
[7] Sahlgrens Univ Hosp, Dept Clin Immunol & Transfus Med KITM, Stockholm, Sweden
[8] Univ Gothenburg, Inst Biomed, Sahlgrenska Acad, Dept Lab Med, Gothenburg, Sweden
关键词
Cardiopulmonary bypass; Coagulation; Ex vivo simulation; Platelet aggregation; Priming solution Thromboelastometry; CARDIOPULMONARY BYPASS; PLATELET-AGGREGATION; COAGULATION; COMPLEMENT; DEXTRAN; ACTIVATION; PROFILE; BLOOD;
D O I
10.1093/icvts/ivae156
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Extracorporeal circulation induces pronounced effects on haemostasis and rheology. To study these, an ex vivo simulation model is an attractive alternative but often requires large amounts of blood. We sought to create a miniaturized roller pump circuit requiring minimal amounts of blood and to test if the circuit could be used to compare coagulation, platelet function and blood rheology between a dextran-based and a crystalloid-based priming solution. METHODS A miniaturized roller pump circuit requiring only 27 ml of blood was created. Blood samples from 8 cardiac surgery patients were mixed with either a dextran-based or a crystalloid-based solution and circulated for 60 min. Coagulation was assessed by rotational thromboelastometry, and platelet function by impedance aggregometry and flow cytometry, before and at 5 and 60 min of circulation. RESULTS A time-dependent impairment of coagulation was observed in both groups. Maximum clot firmness was lower with dextran-based than with crystalloid-based priming at 5 min (HEPTEM 37 +/- 4 vs 43 +/- 4 mm, P < 0.001; EXTEM 37 +/- 4 vs 43 +/- 4 mm, P < 0.001; FIBTEM 3 +/- 2 vs 9 +/- 2 mm, P < 0.001) and at 60 min (HEPTEM 29 +/- 9 vs 38 +/- 5 mm, P < 0.001; EXTEM 30 +/- 7 vs 39 +/- 5 mm, P < 0.001; FIBTEM 3 +/- 2 vs 8 +/- 3 mm, P = 0.002). The EXTEM clotting time was longer with dextran-based solution at 5 (109 +/- 19 vs 63 +/- 7 sec, P < 0.001) and at 60 min (176 +/- 72 vs 73 +/- 7 sec, P = 0.004). CONCLUSIONS The novel miniaturized roller pump circuit can be used to mimic extracorporeal circulation for selected research questions. Dextran-based priming caused a significant impairment in haemostasis compared with a standard crystalloid solution.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] OPERATION OF THE ROLLER PUMP FOR EXTRACORPOREAL CIRCULATION
    HEAD, LR
    COENEN, JP
    ANGOLA, E
    NOGUEIRA, C
    MENDELSOHN, D
    KAY, EB
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1960, 39 (02): : 210 - 220
  • [2] A MINIATURIZED ROLLER-PUMP
    SCHOLFIELD, CN
    JOURNAL OF NEUROSCIENCE METHODS, 1987, 19 (02) : 157 - 161
  • [3] The effect of roller head pump on platelet deterioration during the simulated extracorporeal circulation
    Tatsuya Furugaki
    Osamu Shigeta
    Yukinori Kozuma
    Toru Tsukada
    Tomomi Nakajima
    Hiroaki Sakamoto
    Bryan J. Mathis
    Yuji Hiramatsu
    Yasuyuki Suzuki
    Journal of Artificial Organs, 2021, 24 : 22 - 26
  • [4] The effect of roller head pump on platelet deterioration during the simulated extracorporeal circulation
    Furugaki, Tatsuya
    Shigeta, Osamu
    Kozuma, Yukinori
    Tsukada, Toru
    Nakajima, Tomomi
    Sakamoto, Hiroaki
    Mathis, Bryan J.
    Hiramatsu, Yuji
    Suzuki, Yasuyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (01) : 22 - 26
  • [5] A PUMP FOR EXTRACORPOREAL CIRCULATION
    HALL, JE
    JAMES, PA
    LUCAS, BGB
    WATERSTON, DJ
    LANCET, 1959, 1 (FEB14): : 347 - 347
  • [6] A Novel Valveless Pulsatile Flow Pump for Extracorporeal Blood Circulation
    Anatol, Joaquin
    Vignali, Emanuele
    Gasparotti, Emanuele
    Castro-Ruiz, Francisco
    Rubio, Manuel
    Barrios-Collado, Cesar
    Sierra-Pallares, Jose
    Celi, Simona
    ANNALS OF BIOMEDICAL ENGINEERING, 2025, : 966 - 979
  • [7] A MINIATURIZED CENTRIFUGAL PUMP FOR ASSIST CIRCULATION
    TAGUCHI, S
    YOZU, R
    MORI, A
    AIZAWA, T
    KAWADA, S
    ARTIFICIAL ORGANS, 1994, 18 (09) : 664 - 668
  • [8] Hemolysis and Inflammatory Response to Extracorporeal Circulation during On-Pump CABG: Comparison between Roller and Centrifugal Pump Systems
    Passaroni, Andreia Cristina
    Felicio, Marcello Laneza
    Kerdahi Leite de Campos, Nelson Leonardo
    de Moraes Silva, Marcos Augusto
    Yoshida, Winston Bonida
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 33 (01) : 64 - 71
  • [9] Microbubble Activity in Miniaturized and in Conventional Extracorporeal Circulation
    Camboni, Daniele
    Schmidt, Sebastian
    Philipp, Alois
    Rupprecht, Leopold
    Haneya, Assad
    Puehler, Thomas
    Arlt, Matthias
    Hilker, Michael
    Schmid, Christof
    ASAIO JOURNAL, 2009, 55 (01) : 58 - 62
  • [10] ELECTROCARDIOGRAPHIC ARTIFACT CAUSED BY EXTRACORPOREAL ROLLER-PUMP
    KLEINMAN, B
    SHAH, K
    BELUSKO, R
    BLAKEMAN, B
    JOURNAL OF CLINICAL MONITORING, 1990, 6 (03): : 258 - 259