A novel miniaturized roller pump circuit for simulation of extracorporeal circulation

被引:0
|
作者
Hjarpe, Anders K. [1 ,2 ]
Jeppsson, Anders [3 ,4 ]
Lannemyr, Lukas [2 ,5 ]
Pernbro, Fredrik [2 ,6 ]
Hesse, Camilla [7 ,8 ]
Romlin, Birgitta [2 ,6 ]
机构
[1] Sahlgrens Univ Hosp, Dept Perfus, SE-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Inst Clin Sci, Sahlgrenska Acad, Dept Anaesthes & Intens Care, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Med, Sahlgrenska Acad, Dept Mol & Clin Med, Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Dept Cardiothorac Anaesthes, Gothenburg, Sweden
[6] Queen Silv Childrens Hosp, Dept Paediat Anaesthes & Intens Care, Gothenburg, Sweden
[7] Sahlgrens Univ Hosp, Dept Clin Immunol & Transfus Med KITM, Stockholm, Sweden
[8] Univ Gothenburg, Inst Biomed, Sahlgrenska Acad, Dept Lab Med, Gothenburg, Sweden
关键词
Cardiopulmonary bypass; Coagulation; Ex vivo simulation; Platelet aggregation; Priming solution Thromboelastometry; CARDIOPULMONARY BYPASS; PLATELET-AGGREGATION; COAGULATION; COMPLEMENT; DEXTRAN; ACTIVATION; PROFILE; BLOOD;
D O I
10.1093/icvts/ivae156
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Extracorporeal circulation induces pronounced effects on haemostasis and rheology. To study these, an ex vivo simulation model is an attractive alternative but often requires large amounts of blood. We sought to create a miniaturized roller pump circuit requiring minimal amounts of blood and to test if the circuit could be used to compare coagulation, platelet function and blood rheology between a dextran-based and a crystalloid-based priming solution. METHODS A miniaturized roller pump circuit requiring only 27 ml of blood was created. Blood samples from 8 cardiac surgery patients were mixed with either a dextran-based or a crystalloid-based solution and circulated for 60 min. Coagulation was assessed by rotational thromboelastometry, and platelet function by impedance aggregometry and flow cytometry, before and at 5 and 60 min of circulation. RESULTS A time-dependent impairment of coagulation was observed in both groups. Maximum clot firmness was lower with dextran-based than with crystalloid-based priming at 5 min (HEPTEM 37 +/- 4 vs 43 +/- 4 mm, P < 0.001; EXTEM 37 +/- 4 vs 43 +/- 4 mm, P < 0.001; FIBTEM 3 +/- 2 vs 9 +/- 2 mm, P < 0.001) and at 60 min (HEPTEM 29 +/- 9 vs 38 +/- 5 mm, P < 0.001; EXTEM 30 +/- 7 vs 39 +/- 5 mm, P < 0.001; FIBTEM 3 +/- 2 vs 8 +/- 3 mm, P = 0.002). The EXTEM clotting time was longer with dextran-based solution at 5 (109 +/- 19 vs 63 +/- 7 sec, P < 0.001) and at 60 min (176 +/- 72 vs 73 +/- 7 sec, P = 0.004). CONCLUSIONS The novel miniaturized roller pump circuit can be used to mimic extracorporeal circulation for selected research questions. Dextran-based priming caused a significant impairment in haemostasis compared with a standard crystalloid solution.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Acute Kidney Injury With a Miniaturized Extracorporeal Circuit for Neonatal Cardiopulmonary Bypass
    Boettcher, Wolfgang
    O'Brien, Benjamin
    Photiadis, Joachim
    Habazettl, Helmut
    Eggert-Doktor, Dirk
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (11) : 4045 - 4053
  • [22] Healthcare failure mode effect analysis of a miniaturized extracorporeal bypass circuit
    Overdevest, E. P.
    van Hees, J. W. H.
    Lagerburg, V.
    Kloeze, C.
    van Straten, A. H. M.
    PERFUSION-UK, 2014, 29 (04): : 301 - 306
  • [23] Miniaturized extracorporeal circulation versus off-pump coronary artery bypass grafting: A meta-analysis of randomized controlled trials
    Benedetto, Umberto
    Ng, Colin
    Frati, Giacomo
    Biondi-Zoccai, Giuseppe
    Vitulli, Piergiusto
    Zeinah, Mohamed
    Raja, Shahzad G.
    INTERNATIONAL JOURNAL OF SURGERY, 2015, 14 : 96 - 104
  • [24] The Science of Extracorporeal Ultrafiltration: Introducing a Novel Miniaturized Device
    Sgarabotto, Luca
    Kazory, Amir
    Brendolan, Alessandra
    Di Lullo, Luca
    Zanella, Monica
    Ronco, Claudio
    CARDIORENAL MEDICINE, 2023, 13 (01) : 46 - 55
  • [25] Hemostatic Complications During Neonatal Extracorporeal Membrane Oxygenation: Roller Pump and Centrifugal Pump Driven Circuits
    Vermeer, Harry
    de Jong, Sytse F.
    Koers, Erik J.
    Peeters, Theo L. M.
    van der Lee, Robin
    de Boode, Willem P.
    Morshuis, Wim J.
    ASAIO JOURNAL, 2023, 69 (06) : 618 - 624
  • [26] A new rotary blood pump for versatile extracorporeal circulation:: the DeltaStream™
    Göbel, C
    Arvand, A
    Rau, G
    Reul, H
    Meyns, B
    Flameng, W
    Eilers, R
    Marseille, O
    PERFUSION-UK, 2002, 17 (05): : 373 - 382
  • [27] EXPERIMENTAL STUDY OF A PUMP REGULATING PRESSURES DESTINED FOR EXTRACORPOREAL CIRCULATION
    SAUSSE, A
    STERN, A
    EUROPEAN SURGICAL RESEARCH, 1969, 1 (03) : 234 - &
  • [28] Structure optimization design of extracorporeal circulation blood transport pump
    Liu, Fuwen
    Li, Qingye
    Gong, Zhuangzhuang
    Zhang, Yanfeng
    Song, Xueguan
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2024, 67 (03)
  • [29] Cam Ring Force Simulation for Variable Roller Pump
    Zavadinka, P.
    Grepl, R.
    MECHATRONICS 2013: RECENT TECHNOLOGICAL AND SCIENTIFIC ADVANCES, 2014, : 199 - 206
  • [30] NEW, PULSE-GIVING, HYDRAULIC PUMP FOR EXTRACORPOREAL CIRCULATION
    SORENSEN, AH
    LANCET, 1960, 1 (APR30): : 959 - 960