A novel miniaturized roller pump circuit for simulation of extracorporeal circulation

被引:0
|
作者
Hjarpe, Anders K. [1 ,2 ]
Jeppsson, Anders [3 ,4 ]
Lannemyr, Lukas [2 ,5 ]
Pernbro, Fredrik [2 ,6 ]
Hesse, Camilla [7 ,8 ]
Romlin, Birgitta [2 ,6 ]
机构
[1] Sahlgrens Univ Hosp, Dept Perfus, SE-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Inst Clin Sci, Sahlgrenska Acad, Dept Anaesthes & Intens Care, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Med, Sahlgrenska Acad, Dept Mol & Clin Med, Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Dept Cardiothorac Anaesthes, Gothenburg, Sweden
[6] Queen Silv Childrens Hosp, Dept Paediat Anaesthes & Intens Care, Gothenburg, Sweden
[7] Sahlgrens Univ Hosp, Dept Clin Immunol & Transfus Med KITM, Stockholm, Sweden
[8] Univ Gothenburg, Inst Biomed, Sahlgrenska Acad, Dept Lab Med, Gothenburg, Sweden
关键词
Cardiopulmonary bypass; Coagulation; Ex vivo simulation; Platelet aggregation; Priming solution Thromboelastometry; CARDIOPULMONARY BYPASS; PLATELET-AGGREGATION; COAGULATION; COMPLEMENT; DEXTRAN; ACTIVATION; PROFILE; BLOOD;
D O I
10.1093/icvts/ivae156
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Extracorporeal circulation induces pronounced effects on haemostasis and rheology. To study these, an ex vivo simulation model is an attractive alternative but often requires large amounts of blood. We sought to create a miniaturized roller pump circuit requiring minimal amounts of blood and to test if the circuit could be used to compare coagulation, platelet function and blood rheology between a dextran-based and a crystalloid-based priming solution. METHODS A miniaturized roller pump circuit requiring only 27 ml of blood was created. Blood samples from 8 cardiac surgery patients were mixed with either a dextran-based or a crystalloid-based solution and circulated for 60 min. Coagulation was assessed by rotational thromboelastometry, and platelet function by impedance aggregometry and flow cytometry, before and at 5 and 60 min of circulation. RESULTS A time-dependent impairment of coagulation was observed in both groups. Maximum clot firmness was lower with dextran-based than with crystalloid-based priming at 5 min (HEPTEM 37 +/- 4 vs 43 +/- 4 mm, P < 0.001; EXTEM 37 +/- 4 vs 43 +/- 4 mm, P < 0.001; FIBTEM 3 +/- 2 vs 9 +/- 2 mm, P < 0.001) and at 60 min (HEPTEM 29 +/- 9 vs 38 +/- 5 mm, P < 0.001; EXTEM 30 +/- 7 vs 39 +/- 5 mm, P < 0.001; FIBTEM 3 +/- 2 vs 8 +/- 3 mm, P = 0.002). The EXTEM clotting time was longer with dextran-based solution at 5 (109 +/- 19 vs 63 +/- 7 sec, P < 0.001) and at 60 min (176 +/- 72 vs 73 +/- 7 sec, P = 0.004). CONCLUSIONS The novel miniaturized roller pump circuit can be used to mimic extracorporeal circulation for selected research questions. Dextran-based priming caused a significant impairment in haemostasis compared with a standard crystalloid solution.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] CLOSED-CIRCUIT PERFUSION OF LIVER UTILIZING AN EXTRACORPOREAL CIRCULATION
    ELEY, A
    BRITISH MEDICAL JOURNAL, 1961, 2 (525): : 806 - &
  • [42] Response to Hemostatic Complications During Neonatal Extracorporeal Membrane Oxygenation: Roller Pump and Centrifugal Pump Driven Circuits
    Maul, Timothy M. M.
    Preston, Thomas J. J.
    ASAIO JOURNAL, 2023, 69 (08) : E405 - E405
  • [43] The effects of conventional extracorporeal circulation versus miniaturized extracorporeal circulation on microcirculation during cardiopulmonary bypass-assisted coronary artery bypass graft surgery
    Yuruk, Koray
    Bezemer, Rick
    Euser, Mariska
    Milstein, Dan M. J.
    de Geus, Hilde H. R.
    Scholten, Evert W.
    de Mol, Bas A. J. M.
    Ince, Can
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 15 (03) : 364 - 370
  • [44] Preliminary Tests Using an Auxiliary Device to Adjust Roller Pumps Used in Extracorporeal Circulation
    Costa, E. T.
    Vieira Junior, F. U.
    de Medeiros Junior, J. D.
    Antunes, N.
    Vieira, R. W.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 754 - 757
  • [45] An Original Versatile Nonocclusive Pressure-Regulated Blood Roller Pump for Extracorporeal Perfusion
    Durandy, Yves
    Wang, Shigang
    Uendar, Akif
    ARTIFICIAL ORGANS, 2014, 38 (06) : 469 - 473
  • [46] STUDIES IN OXYGEN CONSUMPTION DURING EXTRACORPOREAL CIRCULATION WITH A PUMP-OXYGENATOR
    ANDERSEN, MN
    SENNING, A
    ANNALS OF SURGERY, 1958, 148 (01) : 59 - 65
  • [47] A COMPACT CENTRIFUGAL BLOOD PUMP FOR EXTRACORPOREAL-CIRCULATION - DESIGN AND PERFORMANCE
    TANAKA, S
    YAMAMOTO, S
    YAMAKOSHI, K
    KAMIYA, A
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (03): : 272 - 278
  • [48] Extracorporeal circulation (ECC) in the rat model using a new miniaturized hollow fiber oxygenator
    Cresce, G. D.
    Mugnai, D.
    Tessari, M.
    Faggian, G.
    Mazzucco, A.
    Kalangos, A.
    Walpoth, B. H.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (08): : 708 - 708
  • [49] COLLOID FILM IN OPTIMIZED EXTRACORPOREAL CIRCULATION: "A POSSIBLE ROAD FOR THE EXTINCTION OF MINIATURIZED CARDIOPULMONARY BYPASS"
    Condello, Ignazio
    JTCVS OPEN, 2023, 14 : 182 - 182
  • [50] Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome
    Wiesenack, C
    Liebold, A
    Philipp, A
    Ritzka, M
    Koppenberg, J
    Birnbaum, DE
    Keyl, C
    ARTIFICIAL ORGANS, 2004, 28 (12) : 1082 - 1088