Microbubble Activity in Miniaturized and in Conventional Extracorporeal Circulation

被引:11
|
作者
Camboni, Daniele [1 ]
Schmidt, Sebastian
Philipp, Alois
Rupprecht, Leopold
Haneya, Assad
Puehler, Thomas
Arlt, Matthias [2 ]
Hilker, Michael
Schmid, Christof
机构
[1] Univ Hosp Regensburg, Dept Cardiothorac Surg, D-93042 Regensburg, Germany
[2] Dept Anesthesiol, Regensburg, Germany
关键词
MINIMIZED CARDIOPULMONARY BYPASS; MICROEMBOLI; REDUCTION;
D O I
10.1097/MAT.0b013e31818f3e8c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Since the establishment of miniaturized extracorporeal circulation (mECC), there has been a great controversy about a possible increased risk of gaseous microembolism as compared to conventional extracorporeal circulation (cECC). From March 2005 to June 2006, a prospective, randomized study, comparing three different mECC (MECC, PRECiSe, Resting Heart) with a cECC (HL30 Maquet) was performed. Ninety-three patients undergoing elective bypass surgery were included. The amount and size of microbubbles during perfusion was detected in the arterial lines utilizing an ultrasound Doppler system. Clinical outcome was compared by evaluating the incidence of postoperative neuropsychological dysfunction, postoperative renal dysfunction and hospitalization as well as the 30-day mortality. The highest microbubble activity was measured in all devices during the first 10 minutes of extracorporeal circulation. The amount of microbubbles was lower in the Resting Heart system (p = 0.01), equal in the MECC system (p = 0.16) and higher using the PRECiSe system as compared to the cECC (p = 0.002). The microbubble diameter did not differ between all groups (p = 0.56). Postoperative neuropsychological dysfunction (p = 0.45), renal dysfunction (p = 0.67), days of hospitalization (p = 0.27), and 30 day-mortality (p = 0.30) did not differ between all groups. A great variability in the occurrence of gaseous microemboli depending on the applied circuit exists. The Resting Heart system has lower, the MECC system an equal and the PRECiSe system depicted a higher activity in comparison to a cECC. The hypothesis about an increased risk in mECC in comparison to cECC with regard to microbubble activity is not supported by our results. ASAIO Journal 2009; 55:58-62.
引用
收藏
页码:58 / 62
页数:5
相关论文
共 50 条
  • [1] A Meta-Analysis of Miniaturized Versus Conventional Extracorporeal Circulation in Valve Surgery
    Wang, Chuangshi
    Hua, Kun
    Yin, Lu
    Wang, Yang
    Li, Wei
    ANNALS OF THORACIC SURGERY, 2016, 102 (06): : 2099 - 2108
  • [2] The effects of conventional extracorporeal circulation versus miniaturized extracorporeal circulation on microcirculation during cardiopulmonary bypass-assisted coronary artery bypass graft surgery
    Yuruk, Koray
    Bezemer, Rick
    Euser, Mariska
    Milstein, Dan M. J.
    de Geus, Hilde H. R.
    Scholten, Evert W.
    de Mol, Bas A. J. M.
    Ince, Can
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 15 (03) : 364 - 370
  • [3] Comparison between conventional extracorporeal circulation (cEEC) and extracorporeal circulation optimized (ECC.O) with respect to microbubble activity (MBB) in the circuit and microembolic signals (MES) in the middle cerebral artery (MCA) of patients
    Perthel, M.
    Proceedings of the XLI Congress of the European Society for Surgical Research, 2006, : 67 - 70
  • [4] Comparison of Transfusion Requirements for Conventional and Miniaturized Extracorporeal Circuits
    Harostock, Michael, III
    Filler, Joseph J.
    Burak, David A.
    McDonnell, Bryan E.
    Emilcar, Jean
    Torres, Albert
    Zimak, Joseph
    Patel, Twinkle
    Harostock, Michael D.
    HEART SURGERY FORUM, 2008, 11 (03): : E188 - E192
  • [5] Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals
    Perthel, M
    Kseibi, S
    Sagebiel, F
    Alken, A
    Laas, J
    PERFUSION-UK, 2005, 20 (06): : 329 - 333
  • [6] Effect of a miniaturized extracorporeal circulation (MECC™ System) on liver function
    Prasser, Christopher
    Abbady, Mohamed
    Keyl, Cornelius
    Liebold, Andreas
    Tenderich, Magda
    Philipp, Alois
    Wiesenack, Christoph
    PERFUSION-UK, 2007, 22 (04): : 245 - 250
  • [7] A novel miniaturized roller pump circuit for simulation of extracorporeal circulation
    Hjarpe, Anders K.
    Jeppsson, Anders
    Lannemyr, Lukas
    Pernbro, Fredrik
    Hesse, Camilla
    Romlin, Birgitta
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 39 (03):
  • [8] How firm is the evidence for miniaturized extracorporeal circulation versus conventional cardiopulmonary bypass for coronary revascularization? A trial sequential analysis
    Phan, Kevin
    Phan, Steven
    Yan, Tristan D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 : 422 - 423
  • [9] Prospective Randomized Comparisonof Miniaturized Extracorporeal Circulation System (MECC) versus Conventional Extracorporeal Circulation System (cecc) in the Prevention of Postoperative Atrial Fibrillation (FA) and Other Clinical Results in Cardiac Surgery Patients
    Ellam, Sten
    Korvenoja, Pekka
    Hartikainen, Juha
    Valtola, Antti
    Hippelainen, Mikko
    Pitkanen, Otto
    Halonen, Jari
    CIRCULATION, 2015, 132
  • [10] Effect of minimal extracorporeal circulation versus conventional extracorporeal circulation on postoperative outcome of coronary artery bypass grafting
    Srivastava P.K.
    Rajan S.D.
    Agrawal S.
    Radakrishnan S.
    Varghese T.
    Cherian K.M.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2010, 26 (1) : 1 - 4