Microbubble Activity in Miniaturized and in Conventional Extracorporeal Circulation

被引:11
|
作者
Camboni, Daniele [1 ]
Schmidt, Sebastian
Philipp, Alois
Rupprecht, Leopold
Haneya, Assad
Puehler, Thomas
Arlt, Matthias [2 ]
Hilker, Michael
Schmid, Christof
机构
[1] Univ Hosp Regensburg, Dept Cardiothorac Surg, D-93042 Regensburg, Germany
[2] Dept Anesthesiol, Regensburg, Germany
关键词
MINIMIZED CARDIOPULMONARY BYPASS; MICROEMBOLI; REDUCTION;
D O I
10.1097/MAT.0b013e31818f3e8c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Since the establishment of miniaturized extracorporeal circulation (mECC), there has been a great controversy about a possible increased risk of gaseous microembolism as compared to conventional extracorporeal circulation (cECC). From March 2005 to June 2006, a prospective, randomized study, comparing three different mECC (MECC, PRECiSe, Resting Heart) with a cECC (HL30 Maquet) was performed. Ninety-three patients undergoing elective bypass surgery were included. The amount and size of microbubbles during perfusion was detected in the arterial lines utilizing an ultrasound Doppler system. Clinical outcome was compared by evaluating the incidence of postoperative neuropsychological dysfunction, postoperative renal dysfunction and hospitalization as well as the 30-day mortality. The highest microbubble activity was measured in all devices during the first 10 minutes of extracorporeal circulation. The amount of microbubbles was lower in the Resting Heart system (p = 0.01), equal in the MECC system (p = 0.16) and higher using the PRECiSe system as compared to the cECC (p = 0.002). The microbubble diameter did not differ between all groups (p = 0.56). Postoperative neuropsychological dysfunction (p = 0.45), renal dysfunction (p = 0.67), days of hospitalization (p = 0.27), and 30 day-mortality (p = 0.30) did not differ between all groups. A great variability in the occurrence of gaseous microemboli depending on the applied circuit exists. The Resting Heart system has lower, the MECC system an equal and the PRECiSe system depicted a higher activity in comparison to a cECC. The hypothesis about an increased risk in mECC in comparison to cECC with regard to microbubble activity is not supported by our results. ASAIO Journal 2009; 55:58-62.
引用
收藏
页码:58 / 62
页数:5
相关论文
共 50 条
  • [21] Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome
    Wiesenack, C
    Liebold, A
    Philipp, A
    Ritzka, M
    Koppenberg, J
    Birnbaum, DE
    Keyl, C
    ARTIFICIAL ORGANS, 2004, 28 (12) : 1082 - 1088
  • [22] CARDIAC RESUSCITATION BY EXTRACORPOREAL-CIRCULATION AFTER FAILURE OF CONVENTIONAL CPR
    GAZMURI, RJ
    WEIL, MH
    VONPLANTA, M
    GAZMURI, RR
    SHAH, DM
    RACKOW, EC
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1991, 118 (01): : 65 - 73
  • [23] Delineation of peripheral vasomotor activity during extracorporeal circulation
    Podgoreanu, M
    Stout, RG
    Ferneini, EM
    Ghobashy, A
    Silverman, DG
    ANESTHESIOLOGY, 2000, 93 (3A) : U139 - U139
  • [24] MONITORING OF HEPARIN ACTIVITY DURING EXTRACORPOREAL-CIRCULATION
    GOMPERTS, ED
    BETHLEHEM, B
    HOCKLEY, J
    SOUTH AFRICAN MEDICAL JOURNAL, 1977, 51 (26): : 973 - 976
  • [25] The Neuroelectric Activity of The Brain in Extracorporeal Circulation: Preliminary Results
    Bayazit, Turan Onur
    MEDICAL JOURNAL OF BAKIRKOY, 2018, 14 (04) : 427 - 432
  • [26] Minimally invasive extracorporeal circulation is a cost-effective alternative to conventional extracorporeal circulation for coronary artery bypass grafting: propensity matched analysis
    Ali, Jason M.
    Kovzel, Maksym
    McPhilimey, Eve
    Colah, Simon
    De Silva, Ravi
    Moorjani, Narain
    PERFUSION-UK, 2021, 36 (02): : 154 - 160
  • [27] Beating-Heart Coronary Artery Bypass Grafting Using a Miniaturized Extracorporeal Circulation System
    Reber, Delawer
    Fritz, Markus
    Tossios, Paschalis
    Buchwald, Dirk
    Lindstaedt, Michael
    Klak, Krzysztof
    Marks, Peter
    Laczkovics, Axel
    HEART SURGERY FORUM, 2008, 11 (05): : E276 - E280
  • [28] Randomized Trial of Miniaturized Versus Standard Extracorporeal Circulation in Aortic Valve Surgery - INVITED COMMENTARY
    Holman, William L.
    ANNALS OF THORACIC SURGERY, 2019, 108 (01): : 44 - 44
  • [29] EXTRACORPOREAL CIRCULATION
    不详
    BRITISH MEDICAL JOURNAL, 1959, 1 (JAN3): : 35 - 36
  • [30] Extracorporeal circulation
    Gilutz, H
    CIRCULATION, 1998, 97 (01) : 117 - 117