A MINIATURIZED CENTRIFUGAL PUMP FOR ASSIST CIRCULATION

被引:11
|
作者
TAGUCHI, S [1 ]
YOZU, R [1 ]
MORI, A [1 ]
AIZAWA, T [1 ]
KAWADA, S [1 ]
机构
[1] NIKKISO CO LTD,TOKYO,JAPAN
关键词
NIKKISO HMS-15; MINIATURIZED CENTRIFUGAL PUMP; HEMOLYSIS; THROMBUS FORMATION; BLOOD TRAUMA;
D O I
10.1111/j.1525-1594.1994.tb03396.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The newly developed Nikkiso HMS-15 is a miniaturized centrifugal pump. It has an impeller diameter of only 50 mm and a priming volume of only 25 mi. A totally new approach was applied to develop this very small pump. The new pump showed comparable hemolysis with pumps twice as big (e.g., the most widely used cone-shaped centrifugal pump [index of hemolysis, 0.005]). This finding refutes the belief that the pump diameter must be sufficiently large in size. Clinical application for cardiac assist was performed for 48 h without any thrombus formation despite low heparin dosage. Also, the pump showed quite favorable blood trauma when applied as a pump for cardiopulmonary bypass during open heart surgery. The compactness, the high controllability, and the system versatility proved to be very effective for clinical application. This pump is considered very reliable for its highly optimized design.
引用
收藏
页码:664 / 668
页数:5
相关论文
共 50 条
  • [1] In vivo evaluation of the miniaturized Gyro centrifugal pump as an implantable ventricular assist device
    Takami, Y
    Otsuka, G
    Mueller, J
    Sugita, Y
    Nakata, K
    Tayama, E
    Ohashi, Y
    Schima, H
    Schmallegger, H
    Wolner, E
    Nose, Y
    ARTIFICIAL ORGANS, 1998, 22 (08) : 713 - 720
  • [2] Impeller design for a miniaturized centrifugal blood pump
    Takano, T
    Schulte-Eistrup, S
    Yoshikawa, M
    Nakata, K
    Kawahito, S
    Maeda, T
    Nonaka, K
    Linneweber, J
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    ARTIFICIAL ORGANS, 2000, 24 (10) : 821 - 825
  • [3] Impeller inner diameter in a miniaturized centrifugal blood pump
    Takano, T
    Schulte-Eistrup, S
    Kawahito, S
    Maeda, T
    Nonaka, K
    Linneweber, J
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    ARTIFICIAL ORGANS, 2002, 26 (01) : 67 - 71
  • [4] Inlet port positioning for a miniaturized centrifugal blood pump
    Takano, T
    Schulte-Eistrup, S
    Kawahito, S
    Maeda, T
    Nonaka, K
    Linneweber, J
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    ARTIFICIAL ORGANS, 2002, 26 (01) : 45 - 48
  • [5] Evaluation of hemolysis in a pulsatile assist device for centrifugal pump
    Department of Cardiovascular Surgery, Fukushima Medical College, Senko Medical Inc., Fukushima, Japan
    不详
    ARTIF. ORGANS, 7 (700-703):
  • [6] Simulation studies on the hemodynamics of a centrifugal ventricular assist pump
    Feng H.
    Wang D.
    Wang K.
    Zhu M.
    International Journal of Fluid Machinery and Systems, 2019, 12 (03) : 181 - 188
  • [7] Evaluation of hemolysis in a pulsatile assist device for centrifugal pump
    Iwaya, F
    Igari, T
    Hoshino, S
    Hikichi, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 700 - 703
  • [8] Development of an implantable centrifugal blood pump for circulatory assist
    Wakisaka, Y
    Taenaka, Y
    Chikanari, K
    Okuzono, Y
    Endo, S
    Takano, H
    ASAIO JOURNAL, 1997, 43 (05) : M608 - M614
  • [9] Performance of a new implantable cardiac assist centrifugal pump
    Tevaearai, HT
    Mueller, XM
    Jegger, D
    Augsburger, M
    Burki, M
    von Segesser, LK
    ARTIFICIAL ORGANS, 2001, 25 (01) : 67 - 69
  • [10] Miniaturized Fontan Circulation Assist Device: Chronic In Vivo Evaluation
    Cysyk, Joshua P.
    Lukic, Branka
    Brian, Clark Joseph
    Newswanger, Ray
    Jhun, Choon-Sik
    Izer, Jenelle
    Flory, Heidi
    Reibson, John
    Doxtater, Bradley
    Weiss, William
    Rosenberg, Gerson
    ASAIO JOURNAL, 2021, 67 (11) : 1240 - 1249