Characterization of a commercial plastic scintillator for electron FLASH dosimetry

被引:0
|
作者
Oh, Kyuhak [1 ]
Hyun, Megan A. [1 ]
Gallagher, Kyle J. [1 ]
Yan, Ying [1 ]
Zhou, Sumin [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE 68198 USA
来源
关键词
dosimetry; electron ultra-high dose rate (eFLASH); FLASH research extension (FLEX); plastic scintillator; BEAM DOSIMETRY; ION RECOMBINATION;
D O I
10.1002/acm2.14451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems.Methods and materialsWe assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film.ResultsWe observed that the 1 x 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 x 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of similar to 1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies.ConclusionsThis study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Doped Plastic Scintillator Properties for Soft Tissue Dosimetry
    Tajudin, S. M.
    Namito, Y.
    Sanami, T.
    Hirayama, H.
    Hashim, S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (09) : 2108 - 2112
  • [22] Plastic scintillator-based dosimeters for FLASH radiotherapy
    Ciarrocchi, E.
    Morrocchi, M.
    Del Sarto, D.
    Di Martino, F.
    Linsalata, S.
    Pensavalle, J. H.
    Bisogni, M. G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S779 - S780
  • [23] A new calibration method of an array of plastic scintillating fibers for dosimetry in electron FLASH Radiotherapy
    Ravera, E.
    Cavalieri, A.
    Ciarrocchi, E.
    Del Sarto, D.
    Di Martino, F.
    Massa, M.
    Masturzo, L.
    Moggi, A.
    Morrocchi, M.
    Pensavalle, J. H.
    Bisogni, M. G.
    RADIATION MEASUREMENTS, 2024, 177
  • [24] Plastic scintillator investigations for relative dosimetry in proton-therapy
    Torrisi, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 170 (3-4): : 523 - 530
  • [25] Computational and experimental small field dosimetry using a commercial plastic scintillator detector for the 0.35 T MR-linac
    Khan, Ahtesham Ullah
    Das, Indra J.
    Yadav, Poonam
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 123
  • [26] ELECTRON DOSIMETRY IN PHANTOMS USING THIN SCINTILLATOR SHEETS
    BRANNEN, E
    OLDE, GL
    PHYSICS IN MEDICINE AND BIOLOGY, 1960, 5 (01): : 37 - 44
  • [27] Characterization of a 0.8 mm3 Medscint plastic scintillator detector system for small field dosimetry
    Timakova, Elena
    Bazalova-Carter, Magdalena
    Zavgorodni, Sergei
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (17):
  • [28] CHARACTERIZATION OF RADIOSENSITIVITY OF A PLASTIC FIBER SCINTILLATOR
    TANAKA, A
    KOJIMA, Y
    POLYMER JOURNAL, 1993, 25 (04) : 407 - 410
  • [29] PLASTIC SCINTILLATOR DOSIMETRY OF ULTRAHIGH DOSERATE 200 MEV ELECTRONS AT CLEAR
    Hart, Alexander
    Giguere, Cloe
    Esplen, Nolan
    Bateman, Joseph
    Korysko, Pierre
    Farabolini, Wilfrid
    Corsini, Roberto
    Dosanjh, Manjit
    Beaulieu, Luc
    Bazalova-Carter, Magdalena
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S20 - S20
  • [30] Time-resolved plastic scintillator dosimetry in a dynamic thorax phantom
    Sibolt, Patrik
    Andersen, Claus E.
    Ottosson, Wiviann
    Behrens, Claus F.
    RADIATION MEASUREMENTS, 2017, 106 : 373 - 377